Start-up strategy of mixed-flow pump system with impulse operation

被引:11
|
作者
Ren, Zhiying [1 ]
Sun, Mingkang [1 ,2 ]
Zhang, Jinsong [2 ]
Wang, Xinlong [3 ]
Huang, Zhenwei [4 ]
Xu, Jin [5 ]
Huang, Chuibing [6 ]
机构
[1] Fuzhou Univ, Inst Met Rubber & Vibrat Noise, Sch Mech Engn & Automat, Fuzhou 350116, Peoples R China
[2] Tsinghua Univ, Dept Energy & Power Engn, Beijing 100084, Peoples R China
[3] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[4] Huazhong Univ Sci & Technol, Sch Naval Architecture & Ocean Engn, Wuhan 430074, Peoples R China
[5] Naval Univ Engn, Natl Key Lab Sci & Technol Vessel Integrated Power, Wuhan 430033, Peoples R China
[6] Naval Univ Engn, Coll Elect Engn, Wuhan 430033, Peoples R China
基金
中国国家自然科学基金;
关键词
Evaluation function; Turbulent kinetic energy; Impact head; Speed scheme; CENTRIFUGAL PUMP; TRANSIENT CHARACTERISTICS; PERFORMANCE; SIMULATION;
D O I
10.1016/j.oceaneng.2023.114058
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
The impact head, tip leakage vortex, and pressure pulsation during start-up can cause vibration and noise in the pump, and affect its hydraulic performance. The linear speed start-up method cannot solve the impact head and vibration problems. Therefore, in this study, a mixed-flow pump was investigated to explore the influence of different speed start-up schemes on the flow field and to optimize them. The rated speed was set to 1634 r/min, and numerical simulations of different start-up schemes were carried out using the standard k-e model. Furthermore, the turbulent kinetic energy distribution of the inlet and outlet sections of the mixed-flow pump during different start-up schemes was provided. In addition, the normalized helicity and blade surface pressure for different start-up schemes were compared. Finally, an evaluation function was proposed to evaluate the stability of the flow field during start-up. The results showed that the evaluation function had four factors related to speed and acceleration during start-up. Factors alpha and gamma were obtained based on the acceleration and speed at 0.2 s and 0.42 s during start-up, respectively. Factor beta was affected by the time taken to reach the rated speed. Parameter delta was determined by the acceleration of the period before reaching the rated speed. Based on the evaluation function, a theoretical scientific selection of speed start-up scheme is proposed to improve the stability of the flow field in the pump during start-up.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Theoretical model of transient mixed-flow pump start-up
    Lu, Yangping
    Ma, Can
    Tan, Lei
    Han, Yadong
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2022, 62 (12): : 1938 - 1944
  • [2] Influence of start-up modes on the noise characteristics of mixed-flow pump during start-up process
    Zhu, Guojun
    Xuan, Yifan
    Feng, Jianjun
    Tang, Zhenbo
    Li, Yunzhe
    Wang, Like
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 214
  • [3] Influence of pump start-up mode on the stability of mixed-flow pumps
    Zhenbo Tang
    Guojun Zhu
    Jianjun Feng
    Yajun Wu
    Kai Liu
    Qiang Lu
    Journal of Mechanical Science and Technology, 2023, 37 : 2949 - 2958
  • [4] Influences of start-up mode on the noise characteristics of mixed-flow pump
    Zhu G.
    Tang Z.
    Feng J.
    Luo X.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2023, 39 (13): : 34 - 42
  • [5] Influence of pump start-up mode on the stability of mixed-flow pumps
    Tang, Zhenbo
    Zhu, Guojun
    Feng, Jianjun
    Wu, Yajun
    Liu, Kai
    Lu, Qiang
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (06) : 2949 - 2958
  • [6] Experimental Study on the Stability of Mixed-Flow Pump During Segmented Start-Up Process
    Xuan, Yifan
    Zhu, Guojun
    Luo, Xingqi
    Wang, Yang
    Wang, Like
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024,
  • [7] Experimental study on pressure vibration characteristics of mixed-flow pump during start-up
    Li W.
    Lu D.
    Ma L.
    Ji L.
    Wu P.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2021, 37 (01): : 44 - 50
  • [8] Optimizing configuration of vertical mixed-flow pump start-up parameters based on orthogonal test
    Liu, Mei-Qing, 1600, South China University of Technology (42):
  • [9] Hydraulic loss characteristics of closed-loop piping system during start-up process of mixed-flow pump
    Li, We
    Huang, Yuxin
    Ji, Leilei
    Ma, Lingling
    Agarwal, Ramesh
    ENGINEERING COMPUTATIONS, 2024, 41 (01) : 86 - 106
  • [10] Investigation on the flow and induced-noise mechanism during the transient start-up process of a mixed-flow pump
    Zhang, Jinsong
    Wang, Xinlong
    Yang, Chen
    Sun, Mingkang
    Huang, Zhenwei
    ENGINEERING COMPUTATIONS, 2024, 41 (03) : 727 - 754