Influence of non-ideal line-reflect-match calibration standards on vector network analyzer S-parameter measurements

被引:2
|
作者
Zhao, Wei [1 ,5 ]
Cheng, Chunyue [2 ]
Yang, Chao [3 ]
Xiao, Jiankang [1 ]
Wang, Yibang [1 ,4 ]
Huo, Ye [4 ]
机构
[1] Xidian Univ, Minist Educ, Key Lab Elect Equipment Struct Design, Xian, Peoples R China
[2] Beijing Inst Radio Metrol & Measurement, Sci & Technol Metrol & Calibrat Lab, Beijing, Peoples R China
[3] Xian Univ Posts & Telecommun, Sch Sci, Xian, Peoples R China
[4] Hebei Semicond Res Inst, Dept Metrol & Maintenance, Shijiazhuang, Peoples R China
[5] Xidian Univ, Minist Educ, Key Lab Elect Equipment Struct Design, 2 South Taibai Rd, Xian 710071, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
calibration; microwave measurement; sensitivity analysis; vector network analyzer (VNA); UNCERTAINTY;
D O I
10.1049/smt2.12150
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, an improved two-step method is presented for the sensitivity analysis of vector network analyzer (VNA) S-parameter measurements due to the non-ideal line-reflect-match (LRM) calibration standards. This improved method is based on the indirect uncertainty propagation mechanism, which is especially suitable for the S-parameter measurements applying the self-calibration technique. To further simplify the formula derivation, the deviation matrices [delta A] and [delta B] are newly defined to represent the uncertainties of the T-matrices of error boxes. With this definition, formulas for the deviations of device under test (DUT) S-parameters can be concluded as functions of [delta A] and [delta B] in a concise form. Eventually, by solving only three linear combinations of the elements from [delta A] and [delta B], the sensitivity coefficients of DUT S-parameters due to non-ideal LRM can be conveniently deduced in an analytical form. Finally, experiments are performed to verify the proposed method.
引用
收藏
页码:257 / 268
页数:12
相关论文
共 27 条
  • [21] Influence of nonideal LRL or TRL calibration elements on VNA S-parameter measurements
    Stumper, U.
    ADVANCES IN RADIO SCIENCE, 2005, 3 : 51 - 58
  • [22] Comparison of TRL Calibration Standards and Techniques for Waveguide S-parameter Measurements up to Terahertz Frequencies
    Skinner, James
    Campion, James
    Ridler, Nick
    2023 53RD EUROPEAN MICROWAVE CONFERENCE, EUMC, 2023, : 584 - 587
  • [23] Uncertainties associated with many-port (>4) S-parameter measurements using a four-port vector network analyzer
    Martens, J
    Judge, DV
    Bigelow, JA
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2004, 52 (05) : 1361 - 1368
  • [24] A calibration method for vector network analyzers using a line and three or more offset-reflect standards
    Liu, Yujie
    Wan, Guobin
    Wu, Changying
    Yashchyshyn, Yevhen
    Wang, Yingfan
    Tu, Limin
    FREQUENZ, 2024, 78 (5-6) : 181 - 193
  • [25] Calibration of the Non Linear Vector Network Analyzer (PNA-X) for probe measurements
    Ouhachi, R.
    Ducatteau, D.
    Gaquiere, C.
    Lacave, T.
    Chevalier, P.
    Gloria, D.
    2011 6TH EUROPEAN MICROWAVE INTEGRATED CIRCUIT CONFERENCE, 2011, : 81 - 84
  • [26] A homodyne multiport network analyzer for S-parameter measurements of microwave N-port circuits/systems
    Boulejfen, N
    Kouki, AB
    Ghannouchi, FM
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2000, 24 (01) : 63 - 67
  • [27] Multiport S-Parameter Calculation from Two-Port Network Analyzer Measurements with or without Switch Matrix
    Heuermarm, Holger
    67TH ARFTG MICROWAVE MEASUREMENTS CONFERENCE: MEASUREMENTS AND DESIGN OF HIGH POWER DEVICES AND SYSTEMS, 2007, : 219 - 222