Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach

被引:4
作者
Avram, George Mihai [1 ]
Prill, Robert [2 ,3 ]
Gurau, Cristian Dorin [1 ]
Georgeanu, Vlad [4 ]
Deleanu, Bogdan [5 ]
Russu, Octav [6 ]
Becker, Roland [2 ,3 ]
Predescu, Vlad [1 ]
机构
[1] Ponderas Acad Hosp, Orthopaed & Traumatol Dept, Bucharest 014142, Romania
[2] Univ Hosp Brandenburg Havel, Ctr Orthopaed & Traumatol, Brandenburg Med Sch Theodor Fontane, D-14770 Brandenburg Adh, Germany
[3] Brandenburg Med Sch Theodor Fontane, Fac Hlth Sci Brandenburg, D-14770 Brandenburg Adh, Germany
[4] Clin Emergency Hosp St Pantelimon, Orthopaed & Traumatol Dept, Bucharest, Romania
[5] Univ Med & Farm Timisoara, Orthopaed & Traumatol Dept, Timisoara, Romania
[6] Univ Med, Orthopaed & Traumatol Dept, Pharm Sci & Technol George Emil Palade, Targu Mures 540139, Romania
关键词
Hip arthroplasty; MAKO; Anterior-based muscle sparing; Acetabular cup; LEG LENGTH DISCREPANCY;
D O I
10.1007/s00264-023-05835-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe modified anterolateral approach (Rottinger) for total hip arthroplasty (THA) offers great advantages over conventional approaches, especially concerning early postoperative symptoms, which are mild and well tolerated by patients. Robotic-assisted implantation might facilitate rapid adoption of the modified anterolateral approach without exposing surgeons to risks encountered during the learning curve. This study posits that the use of robotic assistance in conjunction with the modified anterolateral approach for total hip arthroplasty (THA) can provide a substantial enhancement in the accuracy of cup placement in comparison to manual surgery.MethodsThirty-two robotic-assisted THAs met the inclusion criteria and were matched to 32 conventional cases. Acetabular cup inclination, anteversion, limb-length discrepancy, and acetabular offset were assessed using certified planning software by two independent observers using pre- and postoperative anterior-posterior radiographs. Data was analyzed for normal distribution. Chi(2) test was used to determine whether implanted acetabular cups that were within Lewinnek's safe zones were influenced by type of implantation. Effect size estimates and statistical power analysis were also performed to appreciate the appropriateness of the chosen sample size.ResultsRobotic-assisted implantation was found to significantly improve acetabular cup placement in terms of inclination (p < 0.001) but not anteversion (p = 0.783). Although mean postoperative limb-length discrepancy and mean acetabular offset did not differ between groups, a significantly smaller variance was found in the robotic-assisted group (p < 0.001) and (p = 0.04), respectively. There were no significant differences between the two groups in terms of consistently implanting the acetabular cup within the Lewinnek safe zones p = 0.641 for anteversion and p = 0.230 for inclination, respectively.ConclusionsOur results show that although robotic-assisted acetabular cup implantation performed through the modified anterolateral approach did not significantly differ from conventional implantation, it did offer increased accuracy in cup positioning, acetabular bone preservation, and limb-length restoration.
引用
收藏
页码:2265 / 2273
页数:9
相关论文
共 50 条
  • [31] Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review
    Snijders, Thom E.
    Willemsen, Koen
    van Gaalen, Steven M.
    Castelein, Rene M.
    Weinans, Harrie
    de Gast, Arthur
    HIP INTERNATIONAL, 2019, 29 (01) : 41 - 50
  • [32] Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty - Clinical and radiological results of 60 hips
    Unger, AS
    Lewis, RJ
    Gruen, T
    JOURNAL OF ARTHROPLASTY, 2005, 20 (08) : 1002 - 1009
  • [33] Acetabular cup migration after primary cementless total hip arthroplasty in rheumatoid arthritis and its influencing factors: a comparative study with osteoarthritic hip
    Moon, Jun-Ki
    Jung, Ji-Won
    Kim, Yeesuk
    Yang, Jae-Hyuk
    Park, Ye-Soo
    Kim, Young-Ho
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (06) : 1047 - 1053
  • [34] Acetabular cup migration after primary cementless total hip arthroplasty in rheumatoid arthritis and its influencing factors: a comparative study with osteoarthritic hip
    Jun-Ki Moon
    Ji-Won Jung
    Yeesuk Kim
    Jae-Hyuk Yang
    Ye-Soo Park
    Young-Ho Kim
    International Orthopaedics, 2020, 44 : 1047 - 1053
  • [35] Acetabular and Femoral Component Positioning Using Direct Anterior Approach Versus Posterior Approach in Total Hip Arthroplasty
    Tarun Goyal
    Arghya Kundu Choudhury
    Souvik Paul
    Tushar Gupta
    Lakshmana Das
    Indian Journal of Orthopaedics, 2021, 55 : 1215 - 1224
  • [36] Acetabular and Femoral Component Positioning Using Direct Anterior Approach Versus Posterior Approach in Total Hip Arthroplasty
    Goyal, Tarun
    Choudhury, Arghya Kundu
    Paul, Souvik
    Gupta, Tushar
    Das, Lakshmana
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (05) : 1215 - 1224
  • [37] Non-equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
    Snijders, Thom E.
    Schlosser, Tom P. C.
    van Gaalen, Steven M.
    Castelein, Rene M.
    Weinans, Harry
    de Gast, Arthur
    ORTHOPAEDIC SURGERY, 2019, 11 (02) : 241 - 247
  • [38] Medial placement of the acetabular component in an alumina-on-alumina total hip arthroplasty: a comparative study with propensity score matching
    Yoo, Jeong Joon
    Yoon, Hyeong Jo
    Yoon, Pil Whan
    Lee, Young-Kyun
    Kim, Hee Joong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (03) : 413 - 419
  • [39] Medial placement of the acetabular component in an alumina-on-alumina total hip arthroplasty: a comparative study with propensity score matching
    Jeong Joon Yoo
    Hyeong Jo Yoon
    Pil Whan Yoon
    Young-Kyun Lee
    Hee Joong Kim
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 413 - 419
  • [40] Does body mass index affect restoration of femoral offset, leg length and cup positioning after total hip arthroplasty? A prospective cohort study
    Bariq Al-Amiry
    Georgios Pantelakis
    Sarwar Mahmood
    Bakir Kadum
    Torkel B. Brismar
    Arkan S. Sayed-Noor
    BMC Musculoskeletal Disorders, 20