The Impact of Indoor Environmental Quality on Occupant Satisfaction in Commercial Buildings: A Comparison of Building Expert Opinions and Residents' Experiences

被引:2
|
作者
Mokhtariyan Sorkhan, Fatemeh [1 ]
Roumi, Soheil [2 ]
Soltanzadeh Zarandi, Mohammad [1 ]
Ashraf Ganjouei, Mohammad Ali [1 ]
机构
[1] Shahid Bahonar Univ, Dept Art & Architecture, Kerman 7616913439, Iran
[2] Griffith Univ, Sch Engn & Built Environm, Southport, Qld 4222, Australia
关键词
indoor environmental quality; fuzzy AHP; weighting system; thermal comfort; decision analysis; air quality; commercial buildings; SUPPLIER SELECTION; FUZZY; HEALTH; TOPSIS; METHODOLOGY; FRAMEWORK; LOCATION; COMFORT; DESIGN; MCDM;
D O I
10.3390/en17061473
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper investigates the Indoor Environmental Quality (IEQ) factors influencing occupant satisfaction in commercial buildings in Iran, contrasting the views of building experts (architects and engineers) with those of building occupants. Employing the fuzzy analytical hierarchy process (FAHP), this study focuses on the four primary IEQ factors: thermal comfort, indoor air quality, visual comfort, and acoustic comfort. The study aims to bridge the gap between expert evaluations and occupant perceptions of IEQ factors in commercial buildings in Iran. By examining the disparities in prioritising IEQ factors between these two groups, the study sheds light on the complexities of IEQ assessment and highlights the importance of considering diverse perspectives in optimising indoor environments. Our methodology includes a survey conducted among 30 building experts (15 architects and 15 building engineers) and 102 occupants, employing FAHP to derive the relative importance weights of each IEQ factor. The results highlight significant disparities between architects, engineers, and occupants in prioritising these factors. Architects emphasise visual comfort (42%), while engineers and occupants view thermal comfort (53% and 41%) as the most crucial factor for occupant satisfaction. The study underscores the complexity of IEQ in commercial buildings and the diverse perspectives influencing its assessment. It contributes to the broader discourse on optimising IEQ, emphasising the need for a comprehensive approach that encompasses both technical expertise and occupant experience.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Examining the impact of indoor environmental quality on individual productivity of knowledge workers in green certified buildings
    Nurick, Saul
    Thatcher, Andrew
    JOURNAL OF CORPORATE REAL ESTATE, 2023, 25 (04) : 307 - 324
  • [32] A study and application of the degree of satisfaction with indoor environmental quality involving a building space factor
    Xu, Hong
    Huang, Qiong
    Zhang, Qi
    BUILDING AND ENVIRONMENT, 2018, 143 : 227 - 239
  • [33] Impact of indoor environmental quality (IEQ) factors on occupants' environmental perception and satisfaction in hospital wards
    Wu, Qi
    Li, Nianping
    Cai, Xinran
    He, Yingdong
    Du, Yujiao
    BUILDING AND ENVIRONMENT, 2023, 245
  • [34] Energy, Environmental Impact and Indoor Environmental Quality of Add-Ons in Buildings
    Mastellone, Margherita
    Ruggiero, Silvia
    Papadaki, Dimitra
    Barmparesos, Nikolaos
    Fotopoulou, Anastasia
    Ferrante, Annarita
    Assimakopoulos, Margarita Niki
    SUSTAINABILITY, 2022, 14 (13)
  • [35] The impact of workspace location and indoor environmental quality on employees' satisfaction within office buildings: A case study in Cairo
    Aboulfotouh, Ahmed Khaled
    Tolba, Osama
    Ezzeldin, Sherif
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (08) : 2094 - 2114
  • [36] Sick building syndrome and perceived indoor environmental quality: A survey of apartment buildings in Hong Kong
    Wong, Siu-Kei
    Lai, Lawrence Wai-Chung
    Ho, Daniel Chi-Wing
    Chau, Kwong-Wing
    Lam, Cindy Lo-Kuen
    Ng, Chris Hung-Fai
    HABITAT INTERNATIONAL, 2009, 33 (04) : 463 - 471
  • [37] Field Measurements and Analysis of Indoor Environment, Occupant Satisfaction, and Sick Building Syndrome in University Buildings in Hot Summer and Cold Winter Regions in China
    Weng, Jiantao
    Zhang, Yuhan
    Chen, Zefeng
    Ying, Xiaoyu
    Zhu, Wei
    Sun, Yukai
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2023, 20 (01)
  • [38] The impact of building regulations on indoor environmental quality: the case of detached houses in Jordan
    Ali, Hikmat
    Abed, Amal
    Rababah, Alaa
    ARCHNET-IJAR INTERNATIONAL JOURNAL OF ARCHITECTURAL RESEARCH, 2024, 18 (01) : 102 - 120
  • [39] Impact of Indoor Environmental Quality on Students' Comfort in High School Buildings during the Summer Season in an Extreme Climate
    Amoatey, Patrick
    Al-Jabri, Khalifa
    Al-Saadi, Saleh
    Al-Harthy, Issa
    Al-Khuzairi, Mohammed
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2023, 29 (03)
  • [40] Influence of factors unrelated to environmental quality on occupant satisfaction in LEED and non-LEED certified buildings
    Schiavon, Stefano
    Altomonte, Sergio
    BUILDING AND ENVIRONMENT, 2014, 77 : 148 - 159