Performance characterization of an adaptive-controlled air handling unit to achieve thermal comfort in Dubai climate

被引:4
|
作者
Salins, Sampath Suranjan [1 ]
Kumar, Sreejith Sanal [1 ]
Thommana, Antony John Jose [1 ]
Vincent, Vivian Christo [1 ]
Tejero-Gonzalez, Ana [2 ]
Kumar, Shiva [3 ]
机构
[1] Manipal Acad Higher Educ, Sch Engn & IT, Dubai Campus,PO 345050, Dubai, U Arab Emirates
[2] Univ Valladolid, Dept Energy Engn & Fluid Mech, Valladolid, Castilla & Leon, Spain
[3] Manipal Acad Higher Educ, Manipal Inst Technol, Dept Mech & Mfg Engn, Manipal 576104, India
关键词
Air handling unit; Thermal comfort; Humidification; Dehumidification; Bypass factor; Adaptive control; ENERGY; STRATEGIES; SYSTEMS;
D O I
10.1016/j.energy.2023.127186
中图分类号
O414.1 [热力学];
学科分类号
摘要
Recent technological advancements in the HVAC industry enable optimized occupant thermal satisfaction and system efficiency, thanks to better control of the comfort parameter. Current work aims to automatically control the thermal comfort parameters: dry bulb temperature, air-velocity, and relative humidity. This is achieved using an air handling unit (AHU) equipped with a fresh air control for air quality control, a chiller unit that runs on a VCR cycle for cooling and dehumidification, an ultrasonic mist humidification system, and an air volume control system installed in the ductwork for temperature control. These systems are automatically controlled based on the feedback from various sensors installed in the target space to fit to the ASHRAE Standard 55. Experiments are conducted for varying air velocity at different daytime periods in Dubai. Air temperature and humidity are measured at each stage of the AHU. Total time for achieving thermal comfort is recorded. Results indicated that maximum coefficient of performance (COP), dehumidification effectiveness (DE), humidification effectiveness (HE), predicted mean vote (PMV) and bypass factor were 8.60, 0.96, 36%,-0.62 and 0.48 respectively when outdoor conditions reached 42 degrees C and 50% RH. The operational efficiency of the current adaptive-controlled system is found to be 21.50% more efficient than a conventional system.
引用
收藏
页数:15
相关论文
共 7 条
  • [1] A study of adaptive thermal comfort in a well-controlled climate chamber
    Yang, Yu
    Li, Baizhan
    Liu, Hong
    Tan, Meilan
    Yao, Runming
    APPLIED THERMAL ENGINEERING, 2015, 76 : 283 - 291
  • [2] Thermal comfort and energy performance of a dedicated outdoor air system with ceiling fans in hot and humid climate
    Mihara, Kuniaki
    Sekhar, Chandra
    Takemasa, Yuichi
    Lasternas, Bertrand
    Tham, Kwok Wai
    ENERGY AND BUILDINGS, 2019, 203
  • [3] Experimental investigation of TABS and all air system in tropical savanna climate: A thermal comfort and energy performance study
    Pai, Ananth
    Kumar, Balaji
    ENERGY AND BUILDINGS, 2023, 299
  • [4] Thermal comfort, perceived air quality, and cognitive performance when personally controlled air movement is used by tropically acclimatized persons
    Schiavon, S.
    Yang, B.
    Donner, Y.
    Chang, V. W. -C.
    Nazaroff, W. W.
    INDOOR AIR, 2017, 27 (03) : 690 - 702
  • [5] The role of adaptive thermal comfort in the prediction of the thermal performance of a modern mixed-mode office building in the UK under climate change
    de Wilde, Pieter
    Tian, Wei
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2010, 3 (02) : 87 - 101
  • [6] Objective and Subjective Indoor Air Quality and Thermal Comfort Indices: Characterization of Mediterranean Climate Archetypal Schools After the COVID-19 Pandemic
    Llanos-Jimenez, Jesus
    Suarez, Rafael
    Alonso, Alicia
    Sendra, Juan Jose
    INDOOR AIR, 2024, 2024
  • [7] Validation of Dynamic Natural Ventilation Protocols for Optimal Indoor Air Quality and Thermal Adaptive Comfort during the Winter Season in Subtropical-Climate School Buildings
    Cordero, Antonio Sanchez
    Melgar, Sergio Gomez
    Marquez, Jose Manuel Andujar
    APPLIED SCIENCES-BASEL, 2024, 14 (11):