Impact of Personal Protective Equipment on Cardiopulmonary Resuscitation and Rescuer Safety

被引:0
作者
Cheng, Cheng-Hsin [1 ,2 ]
Cheng, Ya-Yun [3 ]
Yuan, Mei-Kang [4 ,5 ]
Juang, Yow-Jer [6 ]
Zeng, Xuan-Yu [6 ]
Chen, Chung-Yu [6 ,7 ]
Foo, Ning-Ping [8 ]
机构
[1] Chang Jung Christian Univ, Grad Inst Med Sci, Tainan, Taiwan
[2] China Med Univ, Nan Hosp, Dept Neurosurg, Tainan, Taiwan
[3] Natl Sun Yat Sen Univ, Coll Med, Sch Med, Kaohsiung, Taiwan
[4] China Med Univ, Nan Hosp, Dept Radiat Oncol, Tainan, Taiwan
[5] Shu Zen Jr Coll Med & Management, Dept Med Imaging & Radiol, Kaohsiung, Taiwan
[6] Chang Jung Christian Univ, Sch Safety & Hlth Sci, Dept Occupat Safety & Hlth, Tainan, Taiwan
[7] Chan Jung Christian Univ, Occupat Environm & Food Safety Res Ctr, Tainan, Taiwan
[8] China Med Univ, Nan Hosp, Dept Emergency Med, Tainan, Taiwan
关键词
QUALITY;
D O I
10.1155/2023/9697442
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. High-quality cardiopulmonary resuscitation (CPR) is a key element in the rescue of cardiac arrest patients but is difficult to achieve in circumstances involving aerosol transmission, such as the COVID-19 pandemic. Methods. This prospective randomized crossover trial included 30 experienced health care providers to evaluate the impact of personal protective equipment (PPE) on CPR quality and rescuer safety. Participants were asked to perform continuous CPR for 5 minutes on a manikin with three types of PPE: level D-PPE, level C-PPE, and PAPR. The primary outcome was effective chest compression per minute. Secondary outcomes were the fit factor by PortaCount, vital signs and fatigue scores before and after CPR, and perceptions related to wearing PPE. Repeated-measures ANOVA was used, and a two-tailed test value of 0.05 was considered statistically significant. Results. The rates of effective chest compressions for 5 minutes with level D-PPE, level C-PPE, and PAPRs were 82.0 +/- 0.2%, 78.4 +/- 0.2%, and 78.0 +/- 0.2%, respectively (). The fit-factor test values of level C-PPE and PAPRs were 182.9 +/- 39.9 vs. 198.9 +/- 9.2 (). The differences in vital signs before and after CPR were not significantly different among the groups. In addition, the fatigue and total perception scores of wearing PPE were significantly higher for level C-PPE than PAPRs: 3.8 +/- 1.6 vs. 3.0 +/- 1.6 () and 27.9 +/- 5.4 vs. 26.0 +/- 5.3 (), respectively. Conclusion. PAPRs are recommended when performing CPR in situations where aerosol transmission is suspected. When PAPRs are in short supply, individual fit-tested N95 masks are an alternative.
引用
收藏
页数:9
相关论文
共 50 条
[21]   Resuscitation of the patient with suspected//confirmed COVID-19 when wearing personal protective equipment: A randomized multicenter crossover simulation trial [J].
Malysz, Marek ;
Dabrowski, Marek ;
Boettiger, Bernd W. ;
Smereka, Jacek ;
Kulak, Klaudia ;
Szarpak, Agnieszka ;
Jaguszewski, Milosz ;
Filipiak, Krzysztof J. ;
Ladny, Jerzy R. ;
Ruetzler, Kurt ;
Szarpak, Lukasz .
CARDIOLOGY JOURNAL, 2020, 27 (05) :497-506
[22]   The Impact of Monitoring on the Initiation of Cardiopulmonary Resuscitation in Children: Friend or Foe? [J].
Hoerner, Elisabeth ;
Schebesta, Karl ;
Huepfl, Michael ;
Kimberger, Oliver ;
Roessler, Bernhard .
ANESTHESIA AND ANALGESIA, 2016, 122 (02) :490-496
[23]   An optimal chest compression technique using personal protective equipment during resuscitation in the COVID-19 pandemic: a randomized crossover simulation study [J].
Malysz, Marek ;
Smereka, Jacek ;
Jaguszewski, Milosz ;
Dabrowski, Marek ;
Nadolny, Klaudiusz ;
Ruetzler, Kurt ;
Ladny, Jerzy R. ;
Sterlinski, Maciej ;
Filipiak, Krzysztof J. ;
Szarpak, Lukasz .
KARDIOLOGIA POLSKA, 2020, 78 (12) :1254-1261
[24]   Two-Thumb or Two-Finger Technique in Infant Cardiopulmonary Resuscitation by a Single Rescuer? A Meta-Analysis with GOSH Analysis [J].
Chang, Chun-Yu ;
Hou, Yueh-Tseng ;
Chien, Yung-Jiun ;
Chen, Yu-Long ;
Lin, Po-Chen ;
Chen, Chien-Sheng ;
Wu, Meng-Yu .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (14) :1-19
[25]   Comparison of the over-the-head, lateral and alternating positions during cardiopulmonary resuscitation performed by a single rescuer with a bag-valve-mask device [J].
Maisch, Stefan ;
Gamon, Eike ;
Ilisch, Alexander ;
Goetz, Alwin E. ;
Schmidt, Gunter N. .
EMERGENCY MEDICINE JOURNAL, 2011, 28 (11) :974-978
[26]   CPR PRO® DEVICE REDUCES RESCUER FATIGUE DURING CONTINUOUS CHEST COMPRESSION CARDIOPULMONARY RESUSCITATION: A RANDOMIZED CROSSOVER TRIAL USING A MANIKIN MODEL [J].
Kovic, Ivor ;
Lulic, Dinka ;
Lulic, Ileana .
JOURNAL OF EMERGENCY MEDICINE, 2013, 45 (04) :570-577
[27]   Comparison of two infant chest compression techniques during simulated newborn cardiopulmonary resuscitation performed by a single rescuer: A randomized, crossover multicenter trial [J].
Smereka, Jacek ;
Madziala, Marcin ;
Szarpak, Lukasz .
CARDIOLOGY JOURNAL, 2019, 26 (06) :761-768
[28]   The impact of a step stool on cardiopulmonary resuscitation: A cross-over mannequin study [J].
Edelson, Dana P. ;
Call, Shawn L. ;
Yuen, Trevor C. ;
Vanden Hoek, Terry L. .
RESUSCITATION, 2012, 83 (07) :874-878
[29]   Rescuer-limited cardiopulmonary resuscitation as an alternative to 2-min switched CPR in the setting of inhospital cardiac arrest: a randomised cross-over study [J].
Jo, Choong Hyun ;
Cho, Gyu Chong ;
Ahn, Jung Hwan ;
Park, Yoo Seok ;
Lee, Chang Hee .
EMERGENCY MEDICINE JOURNAL, 2015, 32 (07) :539-543
[30]   Two-thumb-encircling hands technique is more advisable than 2-finger technique when lone rescuer performs cardiopulmonary resuscitation on infant manikin [J].
Jiang, Jie ;
Zou, Yaru ;
Shi, Wen ;
Zhu, Ying ;
Tao, Ranjun ;
Jiang, Ying ;
Lu, Yiming ;
Tong, Jianjing .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (04) :531-534