Impact of Personal Protective Equipment on Cardiopulmonary Resuscitation and Rescuer Safety

被引:0
|
作者
Cheng, Cheng-Hsin [1 ,2 ]
Cheng, Ya-Yun [3 ]
Yuan, Mei-Kang [4 ,5 ]
Juang, Yow-Jer [6 ]
Zeng, Xuan-Yu [6 ]
Chen, Chung-Yu [6 ,7 ]
Foo, Ning-Ping [8 ]
机构
[1] Chang Jung Christian Univ, Grad Inst Med Sci, Tainan, Taiwan
[2] China Med Univ, Nan Hosp, Dept Neurosurg, Tainan, Taiwan
[3] Natl Sun Yat Sen Univ, Coll Med, Sch Med, Kaohsiung, Taiwan
[4] China Med Univ, Nan Hosp, Dept Radiat Oncol, Tainan, Taiwan
[5] Shu Zen Jr Coll Med & Management, Dept Med Imaging & Radiol, Kaohsiung, Taiwan
[6] Chang Jung Christian Univ, Sch Safety & Hlth Sci, Dept Occupat Safety & Hlth, Tainan, Taiwan
[7] Chan Jung Christian Univ, Occupat Environm & Food Safety Res Ctr, Tainan, Taiwan
[8] China Med Univ, Nan Hosp, Dept Emergency Med, Tainan, Taiwan
关键词
QUALITY;
D O I
10.1155/2023/9697442
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. High-quality cardiopulmonary resuscitation (CPR) is a key element in the rescue of cardiac arrest patients but is difficult to achieve in circumstances involving aerosol transmission, such as the COVID-19 pandemic. Methods. This prospective randomized crossover trial included 30 experienced health care providers to evaluate the impact of personal protective equipment (PPE) on CPR quality and rescuer safety. Participants were asked to perform continuous CPR for 5 minutes on a manikin with three types of PPE: level D-PPE, level C-PPE, and PAPR. The primary outcome was effective chest compression per minute. Secondary outcomes were the fit factor by PortaCount, vital signs and fatigue scores before and after CPR, and perceptions related to wearing PPE. Repeated-measures ANOVA was used, and a two-tailed test value of 0.05 was considered statistically significant. Results. The rates of effective chest compressions for 5 minutes with level D-PPE, level C-PPE, and PAPRs were 82.0 +/- 0.2%, 78.4 +/- 0.2%, and 78.0 +/- 0.2%, respectively (). The fit-factor test values of level C-PPE and PAPRs were 182.9 +/- 39.9 vs. 198.9 +/- 9.2 (). The differences in vital signs before and after CPR were not significantly different among the groups. In addition, the fatigue and total perception scores of wearing PPE were significantly higher for level C-PPE than PAPRs: 3.8 +/- 1.6 vs. 3.0 +/- 1.6 () and 27.9 +/- 5.4 vs. 26.0 +/- 5.3 (), respectively. Conclusion. PAPRs are recommended when performing CPR in situations where aerosol transmission is suspected. When PAPRs are in short supply, individual fit-tested N95 masks are an alternative.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Impact of Personal Protective Equipment on Pediatric Cardiopulmonary Resuscitation Performance A Controlled Trial
    Donoghue, Aaron J.
    Kou, Maybelle
    Good, Grace L.
    Eiger, Carmel
    Nash, Mark
    Henretig, Fred M.
    Stacks, Helen
    Kochman, Adam
    Debski, Julie
    Chen, Jia-Yuh
    Sharma, Gaurav
    Hornik, Christoph P.
    Gosnell, Leigh
    Siegel, David
    Krug, Steven
    Adler, Mark D.
    PEDIATRIC EMERGENCY CARE, 2020, 36 (06) : 267 - 273
  • [2] The intention of healthcare workers to apply personal protective equipment during cardiopulmonary resuscitation
    Lo, S. Y.
    Chow, C. M.
    Chan, C. W.
    INTERNATIONAL JOURNAL OF NURSING PRACTICE, 2012, 18 : 88 - 88
  • [3] Effects of personal protective equipment on cardiopulmonary resuscitation quality and outcomes: A systematic review
    Chung, Sung Phil
    Nehme, Ziad
    Johnson, Nicholas J.
    Lagina, Anthony
    Bray, Janet
    RESUSCITATION PLUS, 2023, 14
  • [4] CARDIOPULMONARY RESUSCITATION - PHYSICAL STRESS ON THE RESCUER
    LONERGAN, JH
    YOUNGBERG, JZ
    KAPLAN, JA
    CRITICAL CARE MEDICINE, 1981, 9 (11) : 793 - 795
  • [5] Chest Compression With Personal Protective Equipment During Cardiopulmonary Resuscitation A Randomized Crossover Simulation Study
    Chen, Jie
    Lu, Kai-Zhi
    Yi, Bin
    Chen, Yan
    MEDICINE, 2016, 95 (14)
  • [6] Analysis of Physiological Response during Cardiopulmonary Resuscitation with Personal Protective Equipment: A Randomized Crossover Study
    Fernandez-Mendez, Maria
    Otero-Agra, Martin
    Fernandez-Mendez, Felipe
    Martinez-Isasi, Santiago
    Santos-Folgar, Myriam
    Barcala-Furelos, Roberto
    Rodriguez-Nunez, Antonio
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [7] Metabolic demands on the rescuer during cardiopulmonary resuscitation
    Reynolds, Stacy L.
    Rittenberger, Jon
    Suyama, Joe
    Hostler, David
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A104 - A104
  • [8] Sports safety matting diminishes cardiopulmonary resuscitation quality and increases rescuer perceived exertion
    Kingston, Thomas
    Tiller, Nicholas B.
    Partington, Elle
    Ahmed, Mukhtar
    Jones, Gareth
    Johnson, Mark I.
    Callender, Nigel A.
    PLOS ONE, 2021, 16 (07):
  • [9] Rescuer fatigue during simulated neonatal cardiopulmonary resuscitation
    E S Li
    P-Y Cheung
    M O'Reilly
    K Aziz
    G M Schmölzer
    Journal of Perinatology, 2015, 35 : 142 - 145
  • [10] Does level D personal protective equipment guard against hazardous biologic agents during cardiopulmonary resuscitation?
    Martin Rodriguez, Francisco
    Fernandez Perez, Cristina
    Castro Villamor, Miguel
    Martin Conty, Jose Luis
    Arnillas Gomez, Pedro
    Casado Vicente, Veronica
    EMERGENCIAS, 2018, 30 (02): : 119 - 122