Bleb morphology of glaucoma drainage devices on magnetic resonance imaging

被引:2
作者
Correia Barao, Rafael [1 ,2 ]
Berhanu, David [3 ,4 ]
Bernardo Matos, Diogo [1 ,2 ]
Barata, Andre Diogo [1 ,2 ]
Sousa, Rita [3 ]
Abegao Pinto, Luis [1 ,2 ]
机构
[1] Hosp Santa Maria, Dept Ophthalmol, CHULN, Lisbon, Portugal
[2] Univ Lisbon, Fac Med, Visual Sci Study Ctr, Lisbon, Portugal
[3] Hosp Santa Maria, Dept Neurol Imaging, CHULN, Lisbon, Portugal
[4] Univ Lisbon, Anat Inst, Fac Med, Lisbon, Portugal
关键词
aqueous shunt; glaucoma; glaucoma surgery; long tube; magnetic resonance imaging; orbit; TREATMENT OUTCOMES; BAERVELDT; SURGERY; IMPLANT; TRABECULECTOMY; TRENDS; TUBE; EYES;
D O I
10.1111/aos.15668
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate bleb morphology features of different glaucoma drainage devices (GDD) using magnetic resonance imaging (MRI). Materials and Methods: Prospective cohort study of GDD and bleb morphology in consecutive glaucoma patients implanted with Ahmed Glaucoma Valve (AGV), Paul Glaucoma Implant (PGI), Baerveldt Glaucoma Implant (BGI) and Ahmed ClearPath (ACP) devices. Thirty-six eyes from 30 consecutive patients underwent standardized GDD implantation followed by MRI at least 1 month after surgery. Main outcomes included bleb volume and endplate position relative to the optic nerve. Secondary outcomes included intraocular pressure (IOP), medication and surgical complications during a 12-month follow-up. Results: Seven eyes were implanted with the AGV (19%), 5 with BGI (14%), 16 with PGI (44%) and 8 with ACP (22%). MRI scans were obtained 85 +/- 66 days after surgery. Mean total bleb volume was 563 +/- 390 mm(3). This bleb volume was inversely correlated with early post-operative IOP (day 7; r(s) = - 0.3326, p = 0.0475) but positively correlated with IOP at 12 months (r(s) = 0.3592, p = 0.0341). No significant difference in total bleb volume was found between GDD types (p = 0.1223). A double-layered bleb was observed in 34 eyes (94%). The inferior bleb volume was significantly larger in PGI devices versus other GDD types (380 +/- 205 vs. 193 +/- 161 mm(3); p = 0.0043). Distance from the endplate to the optic nerve was 9.5 +/- 4.0 mm, similar across GDDs (p = 0.2519). Conclusions: Double-layered blebs are a common finding with GDDs. Bleb volume showed different correlations with IOP at distinct timepoints and the PGI device formed larger blebs. A standardized GDD implantation technique ensures a safe distance from the GDD endplate to the optic nerve.
引用
收藏
页码:789 / 796
页数:8
相关论文
共 50 条
  • [41] A Novel Study Quantifying Intrinsic Dimensional Variation Among Glaucoma Drainage Devices
    Terrell, Jesse A.
    Blake, Charles Richard
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [42] Glaucoma drainage devices: Indications, intraoperative management and postoperative follow-up
    Mercieca, Karl
    Weber, Constance
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2025, 242 (02) : 161 - 173
  • [43] Spontaneous drainage in syringomyelia: magnetic resonance imaging findings
    Bogdanov, EI
    Ibatullin, MM
    Mendelevich, EG
    NEURORADIOLOGY, 2000, 42 (09) : 676 - 678
  • [44] Surgical Management of Hypotony Owing to Overfiltration in Eyes Receiving Glaucoma Drainage Devices
    Stein, Joshua D.
    McCoy, Allison N.
    Asrani, Sanjay
    Herndon, Leon W.
    Lee, Paul P.
    McKinnon, Stuart J.
    Allingham, R. Rand
    Challa, Pratap
    JOURNAL OF GLAUCOMA, 2009, 18 (08) : 638 - 641
  • [45] Glaucoma drainage devices: Indications, intraoperative management and postoperative follow-up
    Mercieca, Karl
    Weber, Constance
    AUGENHEILKUNDE UP2DATE, 2024, 14 (04) : 305 - 319
  • [46] Efficacy of glaucoma drainage devices in uveitic glaucoma and a meta-analysis of the literature
    Wishal D. Ramdas
    Jan Pals
    Aniki Rothova
    Roger C. W. Wolfs
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 143 - 151
  • [47] Spontaneous drainage in syringomyelia: magnetic resonance imaging findings
    E. I. Bogdanov
    M. M. Ibatullin
    E. G. Mendelevich
    Neuroradiology, 2000, 42 : 676 - 678
  • [48] The Impact of Glaucoma Drainage Devices on the Cornea
    Eric Weinlander
    Tomas Meijome
    Manjool Shah
    Current Ophthalmology Reports, 2020, 8 : 159 - 164
  • [49] Magnetic Resonance Imaging in Patients with Implanted Devices
    Beinart, Roy
    Nazarian, Saman
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (09) : 1040 - 1042
  • [50] Outcomes of Trabeculectomy and Glaucoma Drainage Devices for Elevated Intraocular Pressure After Penetrating Keratoplasty
    Yakin, Mehmet
    Eksioglu, Umit
    Yalniz-Akkaya, Zuleyha
    Uzman, Selma
    Singar-Ozdemir, Evin
    Gultekin, Kemal
    Demirok, Gulizar
    Yalvac, Ilgaz
    Ornek, Firdevs
    Burcu, Ayse
    CORNEA, 2018, 37 (06) : 705 - 711