Preclinical evaluation of semi-automated laser ablation for pulmonary vein isolation: A comparative study

被引:1
|
作者
Kuroki, Kenji [1 ]
Reddy, Vivek Y. [1 ]
Iwasawa, Jin [1 ]
Kawamura, Iwanari [1 ]
Neuzil, Petr [2 ]
Estabrook, Brian [3 ]
Melsky, Gerald [3 ]
Dukkipati, Srinivas R. [1 ]
Koruth, Jacob [1 ,4 ]
机构
[1] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, New York, NY USA
[2] Hosp Na Homolce, Dept Cardiol, Prague, Czech Republic
[3] CardioFocus Inc, Marlborough, MA USA
[4] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, One Gustave L Levy Pl,POB 1030, New York, NY 10029 USA
关键词
atrial fibrillation; automated; catheter ablation; endoscopic; laser balloon; POINT-BY-POINT; CATHETER ABLATION; PAROXYSMAL AF; MULTICENTER; BALLOON; TRIAL;
D O I
10.1111/jce.15777
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionVisually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. MethodsAcute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. ResultsAcute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 +/- 5.9, 33.7 +/- 10.0, and 28.0 +/- 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 +/- 17.4% vs.91.9 +/- 25.9%), and circumferentiality (95.8 +/- 6.6% vs. 94.8 +/- 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 +/- 12.7 vs. 21.8 +/- 3.8 min, p = .046 and 4.8 +/- 3.83 vs. 35.4 +/- 4.4, p < .001). ConclusionMotor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [31] Comparison Between Pulmonary Vein Isolation Versus Combination Therapy of Pulmonary Vein Isolation and Ganglionated Plexus Ablation for Atrial Fibrillation
    Naito, Masaki
    Hirai, Kaeko
    Dote, Yoko
    Hashimoto, Yukihiro
    Goryo, Yutaka
    Isojima, Takuya
    Suzuki, Megumi
    Iwama, Hajime
    Nakai, Takehito
    Doi, Naofumi
    Hashimoto, Toshio
    Fujimoto, Hajime
    CIRCULATION, 2013, 128 (22)
  • [32] Laser-based therapy: Is the right answer for pulmonary vein isolation?
    Tondo, Claudio
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (02) : 325 - 326
  • [33] Ablation guided by STAR-mapping in addition to pulmonary vein isolation is superior to pulmonary vein isolation alone or in combination with CFAE/linear ablation for persistent AF
    Honarbakhsh, Shohreh
    Schilling, Richard J.
    Providencia, Rui
    Dhillon, Gurpreet
    Bajomo, Omotomilola
    Keating, Emily
    Finlay, Malcolm
    Hunter, Ross J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 200 - 209
  • [34] The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolation
    Yuji Wakamatsu
    Koichi Nagashima
    Ichiro Watanabe
    Ryuta Watanabe
    Masaru Arai
    Naoto Otsuka
    Seina Yagyu
    Sayaka Kurokawa
    Kimie Ohkubo
    Toshiko Nakai
    Yasuo Okumura
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 277 - 285
  • [35] The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolation
    Wakamatsu, Yuji
    Nagashima, Koichi
    Watanabe, Ichiro
    Watanabe, Ryuta
    Arai, Masaru
    Otsuka, Naoto
    Yagyu, Seina
    Kurokawa, Sayaka
    Ohkubo, Kimie
    Nakai, Toshiko
    Okumura, Yasuo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 55 (03) : 277 - 285
  • [36] Pulmonary vein isolation combined with superior vena cava isolation for atrial fibrillation ablation: a prospective randomized study
    Wang, Xin-Hua
    Liu, Xu
    Sun, Yu-Min
    Shi, Hai-Feng
    Zhou, Li
    Gu, Jia-Ning
    EUROPACE, 2008, 10 (05): : 600 - 605
  • [37] Temperature-Controlled Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation
    Iwasawa, Jin
    Koruth, Jacob S.
    Petru, Jan
    Dujka, Libor
    Kralovec, Stepan
    Mzourkova, Katerina
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Reddy, Vivek Y.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (05) : 542 - 553
  • [38] Outcome of Circumferential Pulmonary Vein Isolation for Ablation of Atrial Fibrillation: A Single Center Experience
    Chen, Jien-Jiun
    Chiu, Fu-Chun
    Chua, Su-Kiat
    Yu, Chieh-Cheh
    Lin, Lian-Yu
    Tsai, Chia-Ti
    Lai, Ling-Ping
    Lin, Jiunn-Lee
    ACTA CARDIOLOGICA SINICA, 2013, 29 (05) : 457 - 461
  • [39] Preclinical evaluation of a novel single-shot pulsed field ablation system for pulmonary vein and atrial ablation
    Aryana, Arash
    Ji, Sang Yong
    Hata, Cary
    de la Rama, Alan
    Nguyen, Ken
    Panescu, Dorin
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (11) : 2203 - 2212
  • [40] Substrate Ablation Without Pulmonary Vein Isolation A Reasonable Proposition for Atrial Fibrillation Ablation?
    Hummel, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (03) : 322 - 324