Preclinical evaluation of semi-automated laser ablation for pulmonary vein isolation: A comparative study

被引:1
|
作者
Kuroki, Kenji [1 ]
Reddy, Vivek Y. [1 ]
Iwasawa, Jin [1 ]
Kawamura, Iwanari [1 ]
Neuzil, Petr [2 ]
Estabrook, Brian [3 ]
Melsky, Gerald [3 ]
Dukkipati, Srinivas R. [1 ]
Koruth, Jacob [1 ,4 ]
机构
[1] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, New York, NY USA
[2] Hosp Na Homolce, Dept Cardiol, Prague, Czech Republic
[3] CardioFocus Inc, Marlborough, MA USA
[4] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, One Gustave L Levy Pl,POB 1030, New York, NY 10029 USA
关键词
atrial fibrillation; automated; catheter ablation; endoscopic; laser balloon; POINT-BY-POINT; CATHETER ABLATION; PAROXYSMAL AF; MULTICENTER; BALLOON; TRIAL;
D O I
10.1111/jce.15777
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionVisually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. MethodsAcute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. ResultsAcute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 +/- 5.9, 33.7 +/- 10.0, and 28.0 +/- 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 +/- 17.4% vs.91.9 +/- 25.9%), and circumferentiality (95.8 +/- 6.6% vs. 94.8 +/- 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 +/- 12.7 vs. 21.8 +/- 3.8 min, p = .046 and 4.8 +/- 3.83 vs. 35.4 +/- 4.4, p < .001). ConclusionMotor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [21] Laser balloon in pulmonary vein isolation for atrial fibrillation: current status and future prospects
    Tohoku, Shota
    Bordignon, Stefano
    Bologna, Fabrizio
    Chen, Shaojie
    Urbanek, Lukas
    Operhalski, Felix
    Chun, K. R. Julian
    Schmidt, Boris
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (11) : 1083 - 1091
  • [22] Pulmonary vein isolation alone versus pulmonary vein isolation with additional extensive ablation for paroxysmal and persistent atrial fibrillation
    Junarta, Joey
    Dikdan, Sean J.
    Upadhyay, Naman
    Molin, Andrea
    Bodempudi, Sairamya
    Warner, Eric
    Joffe, Daniel
    Pang, Zachary
    Frisch, Daniel R.
    JOURNAL OF ARRHYTHMIA, 2022, 38 (04) : 589 - 597
  • [23] Comprehensive dose-response study of pulsed field ablation using a circular catheter compared with radiofrequency ablation for pulmonary vein isolation: A preclinical study
    Hsu, Jonathan C.
    Banker, Rajesh S.
    Gibson, Douglas N.
    Gomez, Tara
    Berman, Dror
    Datta, Keshava
    Chen, Qi
    Doshi, Shephal K.
    HEART RHYTHM O2, 2023, 4 (10): : 662 - 667
  • [24] Pulmonary vein isolation with a novel endoscopic ablation system using laser energy
    Schade, Anja
    Krug, Joachim
    Szoelloesi, Attila-Geza
    El Tarahony, Mohammed
    Deneke, Thomas
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2012, 10 (08) : 995 - 1000
  • [25] Ostial dimensional changes after pulmonary vein isolation: Pulsed field ablation vs radiofrequency ablation
    Kuroki, Kenji
    Whang, William
    Eggert, Charles
    Lam, Jeff
    Leavitt, Jonas
    Kawamura, Iwanari
    Reddy, Ananya
    Morrow, Blake
    Schneider, Christopher
    Petru, Jan
    Turagam, Mohit K.
    Koruth, Jacob S.
    Miller, Marc A.
    Choudry, Subbarao
    Ellsworth, Betsy
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Reddy, Vivek Y.
    HEART RHYTHM, 2020, 17 (09) : 1528 - 1535
  • [26] Pulmonary Vein Isolation Using the Visually Guided Laser Balloon: Results of the US Feasibility Study
    Dukkipati, Srinivas R.
    Woollett, Ian
    McElderry, H. Thomas
    Boehmer, Marie-Christine
    Doshi, Shephal K.
    Gerstenfeld, Edward P.
    Horton, Rodney
    D'Avila, Andre
    Haines, David E.
    Valderrabano, Miguel
    Mangrum, J. Michael
    Ruskin, Jeremy N.
    Natale, Andrea
    Reddy, Vivek Y.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (09) : 944 - 949
  • [27] Radiofrequency Catheter Ablation Targeting the Vein of Marshall in Difficult Mitral Isthmus Ablation or Pulmonary Vein Isolation
    Lee, Ji Hyun
    Nam, Gi-Byoung
    Kim, Minsu
    Hwang, You Mi
    Hwang, Jongmin
    Kim, Jun
    Choi, Kee-Joon
    Kim, You-Ho
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (04) : 386 - 393
  • [28] Pulmonary Vein Isolation With Ablation Index via Single Transseptal Crossing: Critical Role of Carina Isolation
    Rosso, Raphael
    Chorin, Ehud
    Schwartz, Arie Lorin
    Levi, Yuval
    Hochstadt, Aviram
    Viskin, Sami
    HEART LUNG AND CIRCULATION, 2021, 30 (09): : 1373 - 1378
  • [29] Reproducibility of acute pulmonary vein isolation guided by the ablation index
    Solimene, Francesco
    Lepillier, Antoine
    De Ruvo, Ermenegildo
    Scaglione, Marco
    Anselmino, Matteo
    Sebag, Frederic A.
    Pecora, Domenico
    Gallagher, Mark M.
    Rillo, Mariano
    Viola, Graziana
    Rossi, Luca
    De Santis, Valerio
    Landolina, Maurizio
    Castro, Antonello
    Grimaldi, Massimo
    Badenco, Nicolas
    Del Greco, Maurizio
    De Simone, Antonio
    Bertaglia, Emanuele
    Stabile, Giuseppe
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (07): : 874 - 881
  • [30] Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
    Reddy, Vivek Y.
    Neuzil, Petr
    Koruth, Jacob S.
    Petru, Jan
    Funosako, Moritoshi
    Cochet, Hubert
    Sediva, Lucie
    Chovanec, Milan
    Dukkipati, Srinivas R.
    Jais, Pierre