Tunicate Swarm Algorithm based Optimized PID controller for automatic generation control of two area hybrid power system

被引:3
作者
Memon, Abdul Sami [1 ]
Laghari, J. A. [1 ]
Bhayo, Muhammad Akram [1 ]
Khokhar, Suhail [1 ]
Chandio, Sadullah [1 ]
Memon, Muhammad Saleem [1 ]
机构
[1] Quaid e Awam Univ Engn Sci Technol, Dept Elect Engn, Nawabshah, Sindh, Pakistan
关键词
Tunicate Swarm based Automatic generation control; hybrid power system; TSA based Optimized PID controller; Interconnected power system; multi-area power system; LOAD-FREQUENCY CONTROL; WIND POWER; DESIGN; AGC; REQUIREMENTS; FILTER; PLANTS;
D O I
10.3233/JIFS-223227
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In the modern power system, the use of renewable energy sources is increasing rapidly, which makes the system more sensitive. Therefore, it requires effective controllers to operate within the allowable ranges. The existing techniques based on cascaded controllers implemented so far for load frequency control have the advantage of improving the system response. However, this makes the system a more complex and time-consuming process. This makes the system more straightforward, makes it easy to optimize PID parameters, and provides results in acceptable ranges. This paper attempts to solve the load frequency control (LFC) problem in an interconnected hybrid power system with a classical PID controller employing the tunicate swarm algorithm (TSA). This algorithm is used for two areas of an interconnected hybrid power system: thermal, hydro, nuclear, and wind. The PID controller parameters are optimized by tunicate swarm algorithm using integral time absolute error (ITAE) based objective function. To show the robustness of the proposed TSA algorithm, a sensitivity analysis is performed for four case studies ranging from 20% to 30% load increments and decrements. The performance of the proposed TSA algorithm has been compared with the well-known optimization algorithms, particle swarm optimization (PSO), artificial bee colony (ABC), and arithmetic optimization algorithm (AOA) in terms of overshoot, undershoot, and settling time. The simulation results show that the proposed TSA has better optimization capability than PSO, ABC, and AOA in terms of overshoot, undershoot, and settling time.
引用
收藏
页码:2565 / 2578
页数:14
相关论文
共 36 条
  • [1] Design of cascaded controller based on coyote optimizer for load frequency control in multi-area power systems with renewable sources
    Abou El-Ela, Adel A.
    El-Sehiemy, Ragab A.
    Shaheen, Abdullah M.
    Diab, Abd El-Gelil
    [J]. CONTROL ENGINEERING PRACTICE, 2022, 121
  • [2] BFOA based design of PID controller for two area Load Frequency Control with nonlinearities
    Ali, E. S.
    Abd-Elazim, S. M.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 51 : 224 - 231
  • [3] AGC of two-area electric power systems using optimized fuzzy PID with filter plus double integral controller
    Arya, Yogendra
    [J]. JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2018, 355 (11): : 4583 - 4617
  • [4] Ayodele TR, 2012, INT J RENEW ENERGY R, V2, P618
  • [5] Berwal S., 2019, LOAD FREQUENCY CONTR
  • [6] Bevrani H, 2011, INTELLIGENT AUTOMATIC GENERATION CONTROL, P1
  • [7] Bevrani H, 2009, POWER ELECTRON POWER, P1, DOI 10.1007/978-0-387-84878-5_1
  • [8] An Improved ACO Algorithm Optimized Fuzzy PID Controller for Load Frequency Control in Multi Area Interconnected Power Systems
    Chen, Gonggui
    Li, Zhijun
    Zhang, Zhizhong
    Li, Shuaiyong
    [J]. IEEE ACCESS, 2020, 8 : 6429 - 6447
  • [9] DeMarco C., 2014, RENEWABLE ENERGY INT, P369
  • [10] Participation of wind power plants in system frequency control: Review of grid code requirements and control methods
    Diaz-Gonzalez, Francisco
    Hau, Melanie
    Sumper, Andreas
    Gomis-Sellmunt, Oriol
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 34 : 551 - 564