Techno-economic analysis of a combined heat and power system integrating hybrid photovoltaic-thermal collectors, a Stirling engine and energy storage

被引:20
作者
Zhu, Shunmin [1 ,2 ]
Wang, Kai [3 ]
Gonzalez-Pino, Iker [4 ]
Song, Jian [1 ]
Yu, Guoyao [2 ]
Luo, Ercang [2 ]
Markides, Christos N. [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, Clean Energy Proc CEP Lab, South Kensington Campus, London SW7 2AZ, England
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[3] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Peoples R China
[4] Univ Basque Country UPV EHU, Fac Engn Bilbao, Dept Energy Engn, ENEDI Res Grp, Plaza Torres Quevedo 1, Bilbao 48013, Spain
基金
英国工程与自然科学研究理事会;
关键词
Energy conversion; Energy storage; Combined heat and power; Photovoltaic-thermal collector; Stirling engine; MICRO-COMBINED HEAT; ECONOMIC-FEASIBILITY; SOLAR-SYSTEMS; CHP SYSTEMS; PVT SYSTEMS; BATTERY; ELECTRICITY; PROVISION; PERFORMANCE; BUILDINGS;
D O I
10.1016/j.enconman.2023.116968
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a comprehensive analysis of the energetic, economic and environmental performance of a micro-combined heat and power (CHP) system that comprises 29.5 m2 of hybrid photovoltaic-thermal (PVT) collectors, a 1-kWe Stirling engine (SE) and energy storage. First, a model for the solar micro-CHP system, which includes a validated transient model for the SE micro-CHP unit, is developed. Parametric analyses are performed throughout a year to evaluate the effects of key component sizes and operating parameters, including collector flow rate, storage tank size, SE micro-CHP flow rate, and battery capacity, on the energetic, economic and environmental performance of the proposed system using real hourly weather data, and thermal and electrical energy demand profiles of a detached house located in London (UK). The optimum component sizes and oper-ating parameters are determined accordingly. The daily and monthly operating characteristics of the system are evaluated, and its annual performance is compared to those of a reference system (gas boiler plus grid elec-tricity), as well as of other alternative solar-CHP systems including a PVT-assisted heat pump system and a standalone PVT system. The results indicate that the installation of such a system can achieve an annual elec-tricity self-sufficiency of 87% and an annual thermal energy demand coverage of 99%, along with annual pri-mary energy savings and carbon emission reduction rate of 35% and 37% relative to the reference system. Over 30 years of operation, the net present value (NPV) of the proposed system is 1990 pound and the discounted payback period is 28 years. The economics of the proposed system is very sensitive to utility prices, especially the electricity purchase price. Relative to the alternative solar systems, the proposed system offers greater envi-ronmental benefits but has a longer payback period. This implies that although the energy saving and emission reduction potential of the proposed system is significant, the initial/capital investment, especially of the SE CHP unit and the PVT collector array, are currently high, so efforts should focus on the cost reduction of these technologies.
引用
收藏
页数:19
相关论文
共 75 条
  • [1] [Anonymous], 2019, U.S
  • [2] Performance and CO2 emissions assessment of a novel combined solar photovoltaic and thermal, with a Stirling engine micro-CHP system for domestic environments
    Antonio Aunon-Hidalgo, Juan
    Sidrach-de-Cardona, Mariano
    Aunon-Rodriguez, Fernando
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 230
  • [3] Energy self-sufficiency, grid demand variability and consumer costs: Integrating solar PV, Stirling engine CHP and battery storage
    Balcombe, Paul
    Rigby, Dan
    Azapagic, Adisa
    [J]. APPLIED ENERGY, 2015, 155 : 393 - 408
  • [4] Environmental impacts of microgeneration: Integrating solar PV, Stirling engine CHP and battery storage
    Balcombe, Paul
    Rigby, Dan
    Azapagic, Adisa
    [J]. APPLIED ENERGY, 2015, 139 : 245 - 259
  • [5] Baldwin C, P IBPSA CAN ESIN C H, P1
  • [6] Validation of a single tank, multi-mode solar-assisted heat pump TRNSYS model
    Banister, Carsen J.
    Wagar, William R.
    Collins, Michael R.
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2013), 2014, 48 : 499 - 504
  • [7] Baxi Ecogen, 2011, BAXI ECOGEN DUAL ENE
  • [8] Bell M., 2016, Next steps for UK heat policy
  • [9] Guidelines for residential micro-CHP systems design
    Bianchi, Michele
    De Pascale, Andrea
    Spina, Pier Ruggero
    [J]. APPLIED ENERGY, 2012, 97 : 673 - 685
  • [10] Gas Stirling engine μCHP boiler experimental data driven model for building energy simulation
    Bouvenot, J. -B.
    Andlauer, B.
    Stabat, P.
    Marchio, D.
    Flament, B.
    Latour, B.
    Siroux, M.