Finite element analysis of braided dense-mesh stents for carotid artery stenosis

被引:1
作者
Zhao, Yunchuan [1 ]
Cui, Haipo [1 ]
机构
[1] Univ Shanghai Sci & Technol, Shanghai Inst Minimally Invas Therapy, Shanghai, Peoples R China
关键词
Braided dense-mesh stent; carotid artery stenosis; fluid-solid coupling; finite element analysis; FLUID-STRUCTURE INTERACTION; CASPER STENT; BLOOD-FLOW; PLAQUE; RUPTURE; TRIAL; RISK;
D O I
10.1080/10255842.2023.2196597
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
When braided dense-mesh stents are used to treat carotid stenosis, the structural mechanics of vascular stents, the contact mechanics with blood vessels, and the fluid mechanics in the blood environment need to be studied in depth to reduce the damage of stents to blood vessels and the incidence of in-stent restenosis. Three types of braided stents with 8, 16, and 24 strands and laser-cut stents with the corresponding size parameters were designed, and the bending behavior of each of these types of stent, deployment, and fluid dynamic analysis of the 24-strand braided stent were simulated. The results show that the bending stress of the 8-, 16-, and 24-strand braided stents is 46.33%, 50.24%, and 31.86% of that of their laser-cut counterparts. In addition, higher strand density of the braided stents was associated with greater bending stress; after the 24-strand braided stent was expanded within the stented carotid artery, the carotid stenosis rate was reduced from 81.52% to 46.33%. After stent implantation, the maximum stress on the vessel wall in a zero-pressure diastolic environment decreased from 0.34 to 0.20 MPa, the maximum pressure on the intravascular wall surface decreased from 4.89 to 3.98 kPa, the area of high-pressure region decreased, the wall shear force of the stenotic segment throat decreased, and blood flow increased in the stenosis segments. The braided stent had less bending stress and better flexibility than the laser-cut stent under the same stent size parameters; after the 24-strand braided stent was implanted into the stented vessel, it could effectively dilate the vessel, and the blood flow status was improved.
引用
收藏
页码:609 / 619
页数:11
相关论文
共 29 条
  • [1] ANSYS, 2018, ANSYS Fluent 19.2 Theory Guide
  • [2] Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography
    Beller, Ebba
    Klopp, David
    Goettler, Jens
    Kaesmacher, Johannes
    Zimmer, Claus
    Kirschke, Jan S.
    Prothmann, Sascha
    [J]. PLOS ONE, 2016, 11 (04):
  • [3] Restenosis and risk of stroke after stenting or endarterectomy for symptomatic carotid stenosis in the International Carotid Stenting Study (ICSS): secondary analysis of a randomised trial
    Bonati, Leo H.
    Gregson, John
    Dobson, Joanna
    McCabe, Dominick J. H.
    Nederkoorn, Paul J.
    van der Worp, H. Bart
    de Borst, Gert J.
    Richards, Toby
    Cleveland, Trevor
    Mueller, Mandy D.
    Wolff, Thomas
    Engelter, Stefan T.
    Lyrer, Philippe A.
    Brown, Martin M.
    [J]. LANCET NEUROLOGY, 2018, 17 (07) : 587 - 596
  • [4] Cai Y., 2020, MED NOV TECHNOL DEVI, V5, P100031, DOI [10.1016/j.medntd.2020.100031, DOI 10.1016/J.MEDNTD.2020.100031]
  • [5] [Chen Xi 陈曦], 2010, [航天医学与医学工程, Space Medicine & Medical Engineering], V23, P440
  • [6] Effects of Disturbed Flow on Vascular Endothelium: Pathophysiological Basis and Clinical Perspectives
    Chiu, Jeng-Jiann
    Chien, Shu
    [J]. PHYSIOLOGICAL REVIEWS, 2011, 91 (01) : 327 - 387
  • [7] Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion
    Chua, SND
    MacDonald, BJ
    Hashmi, MSJ
    [J]. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2004, 155 : 1772 - 1779
  • [8] Overview of evidence on risk factors and early management of acute carotid stent thrombosis during the last two decades
    Coelho, Andreia Pires
    Lobo, Miguel
    Nogueira, Clara
    Gouveia, Ricardo
    Campos, Jacinta
    Augusto, Rita
    Coelho, Nuno
    Semiao, Ana Carolina
    Canedo, Alexandra
    [J]. JOURNAL OF VASCULAR SURGERY, 2019, 69 (03) : 952 - 964
  • [9] Rupture of the atherosclerotic plaque -: Does a good animal model exist?
    Cullen, P
    Baetta, R
    Bellosta, S
    Bernini, F
    Chinetti, G
    Cignarella, A
    von Eckardstein, A
    Exley, A
    Goddard, M
    Hofker, M
    Hurt-Camejo, E
    Kanters, E
    Kovanen, P
    Lorkowski, S
    McPheat, W
    Pentikäinen, M
    Rauterberg, J
    Ritchie, A
    Staels, B
    Weitkamp, B
    de Winther, M
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2003, 23 (04) : 535 - 542
  • [10] Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy
    Halliday, Alison
    Bulbulia, Richard
    Bonati, Leo H.
    Chester, Johanna
    Cradduck-Bamford, Andrea
    Peto, Richard
    Pan, Hongchao
    [J]. LANCET, 2021, 398 (10305) : 1065 - 1073