Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses

被引:10
作者
Ma, Yun [1 ,2 ]
Guo, Yong-qing [3 ,4 ]
Jiang, Lei [1 ,2 ,3 ,4 ]
Yu, Hao [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Fujian Med Univ, Fujian Key Lab Oral Dis, Fuzhou, Peoples R China
[2] Fujian Med Univ, Sch & Hosp Stomatol, Fujian Prov Engn Res Ctr Oral Biomat & Stomatol Ke, Fujian Coll & Univ, Fuzhou, Peoples R China
[3] Fujian Med Univ, Dept Prosthodont, Fuzhou, Peoples R China
[4] Fujian Med Univ, Res Ctr Dent Esthet & Biomech, Fuzhou, Peoples R China
[5] Nagasaki Univ, Grad Sch Biomed Sci, Dept Appl Prosthodont, Nagasaki, Japan
[6] Fujian Med Univ, Sch & Hosp Stomatol, Dept Prosthodont, Yangqiao Zhong Rd 246, Fuzhou, Peoples R China
关键词
Accuracy; Intraoral conditions; Dental implant; Dental impression technique; Intraoral scanner; IN-VIVO PRECISION; 3-DIMENSIONAL ACCURACY; IMPACT; VITRO;
D O I
10.2186/jpr.JPR_D_22_00242
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the trueness and precision of different impression techniques for two-implant-supported fixed dental prostheses between extraoral and intraoral conditions at different locations.Methods: Six volunteers participated in this study. A resin block with two parallel analogs was fabricated as an implant site simulator (ISS). The ISS was bonded to a molded ethylene vinyl acetate sheet to create a reference model. For each participant, four reference models were prepared based on the locations of the ISSs: maxillary posterior/anterior region (MaxP/MaxA) and mandibular posterior/anterior region (ManP/ManA). Five impressions were taken extraorally using the open-tray (conventional implant impression technique, CIT) and intraoral scanning (digital implant impression technique, DIT) techniques. The reference models were positioned in the participants' mouths, and impressions were obtained intraorally using the CIT and DIT. The interanalog distance (d) and angulation (theta) were measured to calculate trueness (Delta d, Delta theta) and precision (dP, theta P). Two-way ANOVA and t tests were performed (alpha=0.05).Results: For the DIT, under intraoral conditions, the Delta d and Delta theta in MaxP and Delta theta in ManP were significantly higher than those under extraoral conditions. For the CIT, under intraoral conditions, the Delta d and Delta theta in ManA and ManP and Delta theta in MaxP were significantly lower than those under extraoral conditions. No significant differences in the dP and theta P of either DIT or CIT were observed between the two conditions.Conclusions: Intraoral conditions affected the trueness of DIT and CIT in different regions but had no influence on precision.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [31] Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry
    Cheng, Jing
    Zhang, Haidong
    Liu, Hailin
    Li, Junying
    Wang, Hom-Lay
    Tao, Xian
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 560 - 572
  • [32] Accuracy of conventional impressions and digital scans for implant-supported fixed prostheses in maxillary free-ended partial edentulism: An in vitro study
    El Osta, Nada
    Drancourt, Noemie
    Auduc, Chantal
    Veyrune, Jean-Luc
    Nicolas, Emmanuel
    JOURNAL OF DENTISTRY, 2024, 143
  • [33] Investigation of the effects of arch size and implant angulation on the accuracy of digital impression using two intraoral scanners: An in vitro study
    Geramipanah, Farideh
    Sadighpour, Leyla
    Payaminia, Leila
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2023, 9 (06): : 983 - 992
  • [34] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Almeida e Silva, Junio S.
    Erdelt, Kurt
    Edelhoff, Daniel
    Araujo, Elito
    Stimmelmayr, Michael
    Cardoso Vieira, Luiz Clovis
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) : 515 - 523
  • [35] Influence of Loading and Use of Occlusal Splint in Implant-Supported Fixed Prostheses
    Teixeira, Fabiola Marchezini
    de Assis Claro, Cristiane Aparecida
    Claro Neves, Ana Christina
    Rode, Sigmar de Mello
    da Silva-Concilio, Lais Regiane
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (05) : E477 - E480
  • [36] Influence of intraoral scanning coverage on the accuracy of digital implant impressions - An in vitro study
    Wang, Zhen-yu
    Gong, Yu
    Liu, Fei
    Chen, Du
    Shen, Jie-fei
    JOURNAL OF DENTISTRY, 2024, 143
  • [37] Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows
    Sim, Ji-Young
    Jang, Yeon
    Kim, Woong-Chul
    Kim, Hae-Young
    Lee, Dong-Hwan
    Kim, Ji-Hwan
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (01) : 25 - 30
  • [38] Accuracy of the digital implant impression with splinted and non-splinted intraoral scan bodies: A systematic review
    Shetty, Pratiksha Shankar
    Gangurde, Arti P.
    Chauhan, Manish R.
    Jaiswal, Niraja V.
    Salian, Pradnya R.
    Singh, Vikram
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01) : 3 - 12
  • [39] Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners
    Siadat, Hakimeh
    Chitsaz, Foujan
    Zeighami, Somayeh
    Esmaeilzadeh, Alireza
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (02):
  • [40] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117