Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses

被引:9
|
作者
Ma, Yun [1 ,2 ]
Guo, Yong-qing [3 ,4 ]
Jiang, Lei [1 ,2 ,3 ,4 ]
Yu, Hao [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Fujian Med Univ, Fujian Key Lab Oral Dis, Fuzhou, Peoples R China
[2] Fujian Med Univ, Sch & Hosp Stomatol, Fujian Prov Engn Res Ctr Oral Biomat & Stomatol Ke, Fujian Coll & Univ, Fuzhou, Peoples R China
[3] Fujian Med Univ, Dept Prosthodont, Fuzhou, Peoples R China
[4] Fujian Med Univ, Res Ctr Dent Esthet & Biomech, Fuzhou, Peoples R China
[5] Nagasaki Univ, Grad Sch Biomed Sci, Dept Appl Prosthodont, Nagasaki, Japan
[6] Fujian Med Univ, Sch & Hosp Stomatol, Dept Prosthodont, Yangqiao Zhong Rd 246, Fuzhou, Peoples R China
关键词
Accuracy; Intraoral conditions; Dental implant; Dental impression technique; Intraoral scanner; IN-VIVO PRECISION; 3-DIMENSIONAL ACCURACY; IMPACT; VITRO;
D O I
10.2186/jpr.JPR_D_22_00242
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the trueness and precision of different impression techniques for two-implant-supported fixed dental prostheses between extraoral and intraoral conditions at different locations.Methods: Six volunteers participated in this study. A resin block with two parallel analogs was fabricated as an implant site simulator (ISS). The ISS was bonded to a molded ethylene vinyl acetate sheet to create a reference model. For each participant, four reference models were prepared based on the locations of the ISSs: maxillary posterior/anterior region (MaxP/MaxA) and mandibular posterior/anterior region (ManP/ManA). Five impressions were taken extraorally using the open-tray (conventional implant impression technique, CIT) and intraoral scanning (digital implant impression technique, DIT) techniques. The reference models were positioned in the participants' mouths, and impressions were obtained intraorally using the CIT and DIT. The interanalog distance (d) and angulation (theta) were measured to calculate trueness (Delta d, Delta theta) and precision (dP, theta P). Two-way ANOVA and t tests were performed (alpha=0.05).Results: For the DIT, under intraoral conditions, the Delta d and Delta theta in MaxP and Delta theta in ManP were significantly higher than those under extraoral conditions. For the CIT, under intraoral conditions, the Delta d and Delta theta in ManA and ManP and Delta theta in MaxP were significantly lower than those under extraoral conditions. No significant differences in the dP and theta P of either DIT or CIT were observed between the two conditions.Conclusions: Intraoral conditions affected the trueness of DIT and CIT in different regions but had no influence on precision.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [1] The accuracy of conventional versus digital (intraoral scanner or photogrammetry) impression techniques in full-arch implant-supported prostheses: a systematic review
    Joensahakij, Nitchakul
    Serichetaphongse, Pravej
    Chengprapakorn, Wareeratn
    EVIDENCE-BASED DENTISTRY, 2024, 25 (04) : 216 - 217
  • [2] Digital Impressions for Implant-Supported Fixed Dental Prostheses
    Lee S.J.
    Lee J.D.
    Current Oral Health Reports, 2017, 4 (2) : 136 - 141
  • [3] Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations
    Moura, Renata Vasconcellos
    Kojima, Alberto Noriyuki
    Coury Saraceni, Cintia Helena
    Bassolli, Lucas
    Balducci, Ivan
    Ozcan, Mutlu
    Melo Mesquita, Alfredo Mikail
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E530 - E535
  • [4] Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch prostheses: An in vitro study
    Tohme, Hani
    Lawand, Ghida
    Chmielewska, Maja
    Makhzoume, Joseph
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (02): : 354 - 362
  • [5] Comparison of accuracy of two impression techniques for dental implant.
    Hsu, ML
    Huang, YF
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 461 - 461
  • [6] The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis
    Fluegge, Tabea
    van der Meer, Wicher Joerd
    Gonzalez, Beatriz Gimenez
    Vach, Kirstin
    Wismeijer, Daniel
    Wang, Ping
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 374 - 392
  • [7] Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses
    Karl, Matthias
    Graef, Friedrich
    Schubinski, Peter
    Taylor, Thomas
    QUINTESSENCE INTERNATIONAL, 2012, 43 (07): : 555 - 562
  • [8] Comparison of Accuracy Between a Conventional and Two Digital Intraoral Impression Techniques
    Malik, Junaid
    Rodriguez, Jose
    Weisbloom, Michael
    Petridis, Haralampos
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 107 - 113
  • [9] Comparative study of the accuracy of an implant intraoral scanner and that of a conventional intraoral scanner for-arch fixed dental
    Sallorenzo, Alessandro
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1009 - 1016
  • [10] Effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques
    Awad, Eman Mostafa
    ElSheikh, Mohamed Maamoun
    El-Segai, Azza Abd el moneim
    BMC ORAL HEALTH, 2024, 24 (01):