Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses

被引:10
作者
Ma, Yun [1 ,2 ]
Guo, Yong-qing [3 ,4 ]
Jiang, Lei [1 ,2 ,3 ,4 ]
Yu, Hao [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Fujian Med Univ, Fujian Key Lab Oral Dis, Fuzhou, Peoples R China
[2] Fujian Med Univ, Sch & Hosp Stomatol, Fujian Prov Engn Res Ctr Oral Biomat & Stomatol Ke, Fujian Coll & Univ, Fuzhou, Peoples R China
[3] Fujian Med Univ, Dept Prosthodont, Fuzhou, Peoples R China
[4] Fujian Med Univ, Res Ctr Dent Esthet & Biomech, Fuzhou, Peoples R China
[5] Nagasaki Univ, Grad Sch Biomed Sci, Dept Appl Prosthodont, Nagasaki, Japan
[6] Fujian Med Univ, Sch & Hosp Stomatol, Dept Prosthodont, Yangqiao Zhong Rd 246, Fuzhou, Peoples R China
关键词
Accuracy; Intraoral conditions; Dental implant; Dental impression technique; Intraoral scanner; IN-VIVO PRECISION; 3-DIMENSIONAL ACCURACY; IMPACT; VITRO;
D O I
10.2186/jpr.JPR_D_22_00242
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the trueness and precision of different impression techniques for two-implant-supported fixed dental prostheses between extraoral and intraoral conditions at different locations.Methods: Six volunteers participated in this study. A resin block with two parallel analogs was fabricated as an implant site simulator (ISS). The ISS was bonded to a molded ethylene vinyl acetate sheet to create a reference model. For each participant, four reference models were prepared based on the locations of the ISSs: maxillary posterior/anterior region (MaxP/MaxA) and mandibular posterior/anterior region (ManP/ManA). Five impressions were taken extraorally using the open-tray (conventional implant impression technique, CIT) and intraoral scanning (digital implant impression technique, DIT) techniques. The reference models were positioned in the participants' mouths, and impressions were obtained intraorally using the CIT and DIT. The interanalog distance (d) and angulation (theta) were measured to calculate trueness (Delta d, Delta theta) and precision (dP, theta P). Two-way ANOVA and t tests were performed (alpha=0.05).Results: For the DIT, under intraoral conditions, the Delta d and Delta theta in MaxP and Delta theta in ManP were significantly higher than those under extraoral conditions. For the CIT, under intraoral conditions, the Delta d and Delta theta in ManA and ManP and Delta theta in MaxP were significantly lower than those under extraoral conditions. No significant differences in the dP and theta P of either DIT or CIT were observed between the two conditions.Conclusions: Intraoral conditions affected the trueness of DIT and CIT in different regions but had no influence on precision.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [1] Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch prostheses: An in vitro study
    Tohme, Hani
    Lawand, Ghida
    Chmielewska, Maja
    Makhzoume, Joseph
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (02) : 354 - 362
  • [2] Comparison of Accuracy Between a Conventional and Two Digital Intraoral Impression Techniques
    Malik, Junaid
    Rodriguez, Jose
    Weisbloom, Michael
    Petridis, Haralampos
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 107 - 113
  • [3] Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners
    Di Fiore, Adolfo
    Meneghello, Roberto
    Graiff, Lorenzo
    Savio, Gianpaolo
    Vigolo, Paolo
    Monaco, Carlo
    Stellini, Edoardo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 396 - 403
  • [4] Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses
    Takeuchi, Yoshimasa
    Koizumi, Hiroyasu
    Furuchi, Mika
    Sato, Yohei
    Ohkubo, Chikahiro
    Matsumura, Hideo
    JOURNAL OF ORAL SCIENCE, 2018, 60 (01) : 1 - 7
  • [5] Effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques
    Awad, Eman Mostafa
    ElSheikh, Mohamed Maamoun
    El-Segai, Azza Abd el moneim
    BMC ORAL HEALTH, 2024, 24 (01):
  • [6] Accuracy of Impression Techniques for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 715 - 721
  • [7] In Vitro Comparison of the Accuracy of Conventional Impression and Four Intraoral Scanners in Four Different Implant Impression Scenarios
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 39 - 48
  • [8] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02) : 135 - 139
  • [9] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [10] Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction
    Pereira, Ana Larisse Carneiro
    Medeiros, Vitoria Ramos
    Campos, Maria de Fatima Trindade Pinto
    de Medeiros, Annie Karoline Bezerra
    Yilmaz, Burak
    Carreiro, Adriana da Fonte Porto
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (04) : 212 - 222