Shaking table test of a 10-story self-centering tube building

被引:7
作者
Song, Zhaoyang [1 ]
Zhou, Ying [1 ]
Lu, Yiqiu [1 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
post-tensioned wall; precast concrete; resilience; rocking system; seismic performance; self-centering tube; shaking table test; slotted connection; very rare ground motion; PRECAST CONCRETE WALL; SEISMIC PERFORMANCE; BEHAVIOR; ROCKING; SYSTEMS; DESIGN; FRAMES; BARS;
D O I
10.1002/eqe.3827
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The severe damage of conventionally designed buildings and consequent socioeconomic impacts after major seismic events have spurred the development of self-centering systems with high seismic resilience. Post-tensioned (PT) walls with rocking interfaces allowed to open and close and unbonded PT bars that provide most of the re-centering ability have been developed extensively as a promising self-centering technology. Aiming at providing essential insights into the seismic performance of self-centering tube systems, a 1/6-scale ten-story self-centering tube building was designed, constructed, and tested on a shaking table subjected to a series of unidirectional and bidirectional ground motions with increasing intensities. The test building consisted of a self-centering tube that included four PT walls and provided the primary lateral force resistance in both directions, a perimeter rocking frame that was designed mainly to carry gravity loads, and particular connections with slots to accommodate the potential displacement incompatibility among the PT walls and surrounding components. The experimental results indicated the excellent seismic performance of the test building that had reliable structural integrity and experienced only confined damage even when subjected to extremely high intensities. The building also exhibited satisfactory re-centering ability with minimal residual deformations at the conclusion of testing. It was demonstrated that the self-centering tube system is a desirable low-damage alternative to traditional tube systems in earthquake-prone regions. The benchmark data from this test provided unique suggestions and support for further research on the design methods, numerical modeling, and experimental testing of self-centering tube systems.
引用
收藏
页码:1511 / 1535
页数:25
相关论文
共 50 条
  • [31] Shake Table Tests on RC Double-Column Bridge Piers with Self-Centering Energy Dissipation Braces
    Qin, Huailei
    Bi, Kaiming
    Dong, Huihui
    Han, Qiang
    Du, Xiuli
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (08)
  • [32] Shaking table investigation of pulse-type seismic behavior of a self-centering reinforced concrete frame structure
    Zhang, Hongmei
    Fang, Yi
    Cao, Lening
    Hu, Fan
    Duan, Yuanfeng
    ENGINEERING STRUCTURES, 2025, 325
  • [33] Shake-table testing of 2-story steel framed building with self-centering modular panels and slit steel plate walls
    Chu, Gongling
    Wang, Wei
    Zhang, Yunfeng
    ENGINEERING STRUCTURES, 2021, 247
  • [34] Seismic Performance Evaluation of Reinforced Concrete Building Structure Retrofitted with Self-Centering Disc-Slit Damper and Conventional Steel Slit Damper
    Naeem, Asad
    Koichi, Kusunoki
    Lee, Joohno
    BUILDINGS, 2024, 14 (03)
  • [35] Cyclic pushover analysis for seismic response evaluation of a full-scale 10-story steel building tested on the E-Defense shake-table
    Jin, Jialiang
    Nagae, Takuya
    Asai, Tatsuya
    Okazaki, Taichiro
    Li, Jionghui
    Lignos, Dimitrios G.
    Chung, Yu-Lin
    Fujiwara, Jun
    Kishida, Akiko
    Kajiwara, Koichi
    JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [36] Shake Table Tests of Self-Centering Steel Braced Frame with Pretensioned Basalt Fiber Reinforced Polymers
    Wang, Yongwei
    Zhou, Zhen
    Xie, Yazhou
    Huang, Linjie
    Zheng, Jule
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (11) : 3251 - 3268
  • [37] Self-centering companion spines with friction spring dampers: Validation test and direct displacement-based design
    Hu, Shuling
    Wang, Wei
    Qu, Bing
    ENGINEERING STRUCTURES, 2021, 238
  • [38] Shaking table test of a three-story frame with resilient variable friction braces
    Wang, Yongwei
    Zeng, Bin
    Zhou, Zhen
    Huang, Linjie
    Yao, Jiehua
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 192
  • [39] Development of a high-performance hybrid self-centering building for seismic resilience
    Shams, Amir Sina
    Ghobadi, Mohammad Soheil
    ENGINEERING STRUCTURES, 2021, 226
  • [40] Shaking table test and numerical analysis of a high-rise building with steel reinforce concrete column and reinforce concrete core tube
    Lu, Xilin
    Zhou, Bin
    Zhao, Bin
    Lu, Wensheng
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2015, 24 (18) : 1019 - 1038