Accuracy of Intraocular Lens Power Calculation Based on Total Keratometry in Patients With Flat and Steep Corneas

被引:8
|
作者
Qin, Y. I. N. G. Y. A. N. [1 ,2 ]
Liu, L. I. A. N. G. P. I. N. G. [1 ,2 ]
Mao, Y. A. N. [1 ,2 ]
Ding, Y. U. J. I. E. [1 ,2 ]
Ye, S. H. A. O. B., I [1 ,2 ]
Sun, A. O. [1 ,2 ]
Wu, M. I. N. G. X. I. N. G. [1 ,2 ,3 ]
机构
[1] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Peoples R China
[3] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
ASTIGMATISM;
D O I
10.1016/j.ajo.2022.11.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To analyze the accuracy of the current in-traocular lens power calculation formulas using standard keratometry (K) and total keratometry (TK) data in pa-tients with fiat and steep corneas. center dot DESIGN: Retrospective consecutive cross-sectional study. center dot METHODS: An optical biometer with swept-source op-tical coherence tomography was used in this retrospective study. The standard deviation (SD), mean absolute error (MAE), median absolute error (MedAE), and the pro-portion of eyes with prediction error (PE) within +/- 0.25 diopter (D), +/- 0.5 D, +/- 0.75 D, and +/- 1.00 D were calcu-lated to evaluate the refractive outcomes of each formula. center dot RESULTS: A total of 231 eyes from 231 patients were included. In the entire study cohort, the Emmetropia Verifying Optical (EVO) formula using TK data showed the lowest SD (0.383) and MAE (0.30) and the highest percentage of cases with a PE within +/- 0.5 D (81.4%). In the fiat keratometry group, the EVO ( P = .042), Haigis ( P = .043), Hoffer Q ( P = .038) and Holladay 1 ( P = .013) formulas using TK data had significantly lower SD than using K data. The EVO formula using TK data showed the lowest SD (0.357) and MAE (0.28). In the steep keratometry group, the Hoffer Q ( P = .036) and SRK/T ( P = .029) formulas using TK data had sig-nificantly lower SD than using K data. The BUII TK formula showed the lowest SD (0.431), MedAE (0.26), and MAE (0.32). center dot CONCLUSION: The TK data set showed a better trend of refractive outcomes, especially in the fiat and steep ker-atometry groups. EVO (TK) and BUII TK formulas were suggested for eyes with K values lower than 42 D and K values higher than 46 D, respectively. (Am J Ophthal-mol 2023;247: 103-110. (c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [11] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Hun Lee
    Jae Lim Chung
    Young Jun Kim
    Jae Yong Kim
    Hungwon Tchah
    Scientific Reports, 11
  • [12] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Lee, Hun
    Chung, Jae Lim
    Kim, Young Jun
    Kim, Jae Yong
    Tchah, Hungwon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [13] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Ling Wei
    Kaiwen Cheng
    Wenwen He
    Xiangjia Zhu
    Yi Lu
    Eye and Vision, 9
  • [14] Intraocular lens bicylindric power calculation method: Using both flat and steep K readings to improve intraocular lens power prediction
    Calvo-Sanz, Jorge A.
    Ruiz-Alcocer, Javier
    Sanchez-Tena, Miguel A.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (05) : 559 - 565
  • [15] Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (09): : 1140 - 1148
  • [16] Standard vs total keratometry for intraocular lens power calculation in cataract surgery combined with DMEK
    Khan, Asher
    Rangu, Neal
    Murphy, David A.
    Cooke, David L.
    Siatkowski, Rhea L.
    Mittal, Aman
    Wendelstein, Jascha A.
    Riaz, Kamran M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (03): : 239 - 245
  • [17] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Wei, Ling
    Cheng, Kaiwen
    He, Wenwen
    Zhu, Xiangjia
    Lu, Yi
    EYE AND VISION, 2022, 9 (01)
  • [18] Accuracy of intraocular lens calculation formulas in cataract patients with steep corneal curvature
    Zhang, Chenguang
    Dai, Guangzheng
    Pazo, Emmanuel Eric
    Xu, Ling
    Wu, Xianwei
    Zhang, Hongda
    Lin, Tiezhu
    He, Wei
    PLOS ONE, 2020, 15 (11):
  • [19] Simulated Keratometry Versus Total Corneal Power by Ray Tracing: A Comparison in Prediction Accuracy of Intraocular Lens Power
    Savini, Giacomo
    Hoffer, Kenneth J.
    Lomoriello, Domenico Schiano
    Ducoli, Pietro
    CORNEA, 2017, 36 (11) : 1368 - 1372
  • [20] Comparison of intraocular lens power calculation formulas with and without total keratometry and ray tracing in patients with previous myopic SMILE
    Elotmani, Anouar Meziane
    Messerschmidt-Roth, Anke
    Nehme, Alexandra
    Mueller, Hans-Helge
    Sekundo, Walter
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (05): : 467 - 473