Accuracy of Intraocular Lens Power Calculation Based on Total Keratometry in Patients With Flat and Steep Corneas

被引:9
|
作者
Qin, Y. I. N. G. Y. A. N. [1 ,2 ]
Liu, L. I. A. N. G. P. I. N. G. [1 ,2 ]
Mao, Y. A. N. [1 ,2 ]
Ding, Y. U. J. I. E. [1 ,2 ]
Ye, S. H. A. O. B., I [1 ,2 ]
Sun, A. O. [1 ,2 ]
Wu, M. I. N. G. X. I. N. G. [1 ,2 ,3 ]
机构
[1] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Peoples R China
[3] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
ASTIGMATISM;
D O I
10.1016/j.ajo.2022.11.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To analyze the accuracy of the current in-traocular lens power calculation formulas using standard keratometry (K) and total keratometry (TK) data in pa-tients with fiat and steep corneas. center dot DESIGN: Retrospective consecutive cross-sectional study. center dot METHODS: An optical biometer with swept-source op-tical coherence tomography was used in this retrospective study. The standard deviation (SD), mean absolute error (MAE), median absolute error (MedAE), and the pro-portion of eyes with prediction error (PE) within +/- 0.25 diopter (D), +/- 0.5 D, +/- 0.75 D, and +/- 1.00 D were calcu-lated to evaluate the refractive outcomes of each formula. center dot RESULTS: A total of 231 eyes from 231 patients were included. In the entire study cohort, the Emmetropia Verifying Optical (EVO) formula using TK data showed the lowest SD (0.383) and MAE (0.30) and the highest percentage of cases with a PE within +/- 0.5 D (81.4%). In the fiat keratometry group, the EVO ( P = .042), Haigis ( P = .043), Hoffer Q ( P = .038) and Holladay 1 ( P = .013) formulas using TK data had significantly lower SD than using K data. The EVO formula using TK data showed the lowest SD (0.357) and MAE (0.28). In the steep keratometry group, the Hoffer Q ( P = .036) and SRK/T ( P = .029) formulas using TK data had sig-nificantly lower SD than using K data. The BUII TK formula showed the lowest SD (0.431), MedAE (0.26), and MAE (0.32). center dot CONCLUSION: The TK data set showed a better trend of refractive outcomes, especially in the fiat and steep ker-atometry groups. EVO (TK) and BUII TK formulas were suggested for eyes with K values lower than 42 D and K values higher than 46 D, respectively. (Am J Ophthal-mol 2023;247: 103-110. (c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:103 / 110
页数:8
相关论文
共 24 条
  • [11] Clinical application of bicylindric intraocular lens power calculation method
    Calvo-Sanz, Jorge A.
    Bonnin-Arias, Cristina
    Arias-Puente, Alfonso
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (06) : 1073 - 1078
  • [12] Predictability of Intraocular Lens Power Calculation for Cataract with Keratoconus: A Multicenter Study
    Kamiya, Kazutaka
    Iijima, Kei
    Nobuyuki, Shoji
    Mori, Yosai
    Miyata, Kazunori
    Yamaguchi, Takefumi
    Shimazaki, Jun
    Watanabe, Shinya
    Maeda, Naoyuki
    SCIENTIFIC REPORTS, 2018, 8
  • [13] Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method
    Kim, Mingue
    Eom, Youngsub
    Lee, Hwa
    Suh, Young-Woo
    Song, Jong Suk
    Kim, Hyo Myung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (02) : 1016 - 1024
  • [14] Predictability of Intraocular Lens Power Calculation After Simultaneous Pterygium Excision and Cataract Surgery
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Iijima, Kei
    Shoji, Nobuyuki
    Kobashi, Hidenaga
    MEDICINE, 2015, 94 (52)
  • [15] Effect of trabeculectomy on the accuracy of intraocular lens calculations in patients with open-angle glaucoma
    Bae, Hyoung Won
    Lee, Yun Ha
    Kim, Do Wook
    Lee, Taekjune
    Hong, Samin
    Seong, Gong Je
    Kim, Chan Yun
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 (06) : 465 - 471
  • [16] Comparison of measured corneal astigmatism and accuracy of intraocular lens power calculations using six different devices
    Ventura, Bruna
    Wang, Li
    Subramanyam, Sumitra
    Koch, Douglas D.
    Weikert, Mitchell P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [17] Cataract in keratoconus: Six-month results and a comparison of standard intraocular lens power calculation formulas
    Said, Reeda B.
    Farah, Chahid
    Chanbour, Wassef
    Jarade, Elias
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2022, 36 (02) : 201 - 206
  • [18] Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power
    Davison, James A.
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 1511 - 1517
  • [19] Accuracy of intraocular lens power calculation using three optical biometry measurement devices: the OA-2000, Lenstar-LS900 and IOLMaster-500
    Reitblat, Olga
    Levy, Adi
    Kleinmann, Guy
    Assia, Ehud, I
    EYE, 2018, 32 (07) : 1244 - 1252
  • [20] Effect of two different preoperative calculation schemes on visual outcomes of patients after toric intraocular lens implantation
    Yu, Xuewen
    Wang, Jingwen
    Lin, Xueqi
    Xu, Dejian
    Ni, Shuang
    Sheng, Siting
    Xu, Wen
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (02) : 491 - 501