Wireless charging for cardiac pacemakers based on class-D power amplifier and a series-parallel spider-web coil

被引:5
作者
Mahmood, Amal Ibrahim [1 ,2 ]
Gharghan, Sadik Kamel [2 ]
Eldosoky, Mohamed A. [1 ]
Soliman, Ahmed M. [1 ]
机构
[1] Helwan Univ, Fac Engn, Biomed Engn Dept, Cairo 11792, Egypt
[2] Middle Tech Univ, Elect Engn Tech Coll, Baghdad, Iraq
关键词
cardiac pacemaker; implantable medical devices; magnetic-resonant coupling; near-field WPT; spider-web coil; TRANSFER SYSTEM; DESIGN; TOPOLOGIES; EFFICIENCY; LINK; WPT;
D O I
10.1002/cta.3420
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Biomedical implants (BMIs) and biomedical sensors (BMSs) help to improve quality of life, detect diseases, provide monitoring of vital signs, and take over the role of malfunctioning organs. These implants and sensors require continuous battery power to work effectively, but the batteries used are restricted by their limited capacity and lifetime. This research reported here involved the design and implementation of a wireless charging system based on a series-parallel spider-web coil (WPT-SP-SWC), specifically for cardiac pacemakers. The experimental design investigated several important parameters, including air gap, applied source voltage, coil size, and operating frequency. Performance metrics were evaluated in terms of output DC voltage, delivered output power, and power transfer efficiency. The target voltage was 5 V, which is adequate to charge a BMI such as a pacemaker, and three source voltages (5, 15, and 25 V) were tested. The design was examined at six operating frequencies, ranging from 1.78 MHz to 6.78 MHz. The most favorable results were achieved at 1.78 MHz. Power transfer efficiencies at a 10 mm air gap were 95.75% and 92.08% for applied voltages of 5 V and 15 V, respectively. The effectiveness of the proposed system was also validated by comparing the findings with previous articles.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 62 条
[1]  
Abatti Paulo J., 2015, J. Microw. Optoelectron. Electromagn. Appl., V14, P97
[2]   Magnetically Coupled Resonance WPT: Review of Compensation Topologies, Resonator Structures with Misalignment, and EMI Diagnostics [J].
Abou Houran, Mohamad ;
Yang, Xu ;
Chen, Wenjie .
ELECTRONICS, 2018, 7 (11)
[3]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[4]   Optimal Transmit Coil Design for Wirelessly Powered Biomedical Implants Considering Magnetic Field Safety Constraints [J].
Andersen, Erik ;
Casados, Curtis ;
Binh Duc Truong ;
Roundy, Shad .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (05) :1735-1747
[5]   On the Design of Miniature MedRadio Implantable Antennas [J].
Bakogianni, Sofia ;
Koulouridis, Stavros .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2017, 65 (07) :3447-3455
[6]   A power conversion chain with an internally-set voltage reference and reusing the power receiver coil for wireless bio-implants [J].
Barati, Mahdi ;
Yavari, Mohammad .
MICROELECTRONICS JOURNAL, 2018, 74 :69-78
[7]   A power efficient buck-boost converter by reusing the coil inductor for wireless bio-implants [J].
Barati, Mahdi ;
Yavari, Mohammad .
INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2017, 45 (11) :1673-1685
[8]   A review of wireless power transfer for electric vehicles: Prospects to enhance sustainable mobility [J].
Bi, Zicheng ;
Kan, Tianze ;
Mi, Chunting Chris ;
Zhang, Yiming ;
Zhao, Zhengming ;
Keoleian, Gregory A. .
APPLIED ENERGY, 2016, 179 :413-425
[9]   Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review [J].
Bocan, Kara N. ;
Sejdic, Ervin .
SENSORS, 2016, 16 (03)
[10]   Coil Design of a Wireless Power-Transfer Receiver Integrated into a Left Ventricular Assist Device [J].
Campi, Tommaso ;
Cruciani, Silvano ;
Maradei, Francesca ;
Feliziani, Mauro .
ELECTRONICS, 2021, 10 (08)