Contribution of Soft Tissue Passive Forces in Thumb Carpometacarpal Joint Distraction

被引:0
作者
Hafiz, Hamed [1 ]
Yousefsani, Seyed Abdolmajid [1 ]
Moradi, Ali [2 ]
Akbarzadeh, Alireza [3 ]
Jirofti, Nafiseh [2 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, POB 9177948974, Mashhad, Iran
[2] Mashhad Univ Med Sci, Orthoped Res Ctr, Dept Orthoped Surg, Mashhad, Iran
[3] Ferdowsi Univ Mashhad, FUM Ctr Adv Rehabil & Robot Res FUM CARE, Dept Mech Engn, Mashhad, Iran
关键词
Thumb carpometacarpal joint; Passive force; Joint distraction; Musculoskeletal modeling; Tendon; Ligament; CLINICAL BENEFIT; DYNAMIC-MODEL; OSTEOARTHRITIS; MUSCLE; HAND; PARAMETERS; STIFFNESS; BEHAVIOR; FINGER; MOMENT;
D O I
10.1007/s10439-024-03492-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thumb carpometacarpal joint space changes when the surrounding soft tissues including the capsule, ligaments, and tendons are stretched or pulled away. When at rest, joint forces originate from passive contraction of muscles and the involvement of joint capsule and ligaments. Previous biomechanical models of hand and finger joints have mostly focused on the assessment of joint properties when muscles were active. This study aims to present an experimental-numerical biomechanical model of thumb carpometacarpal joint to explore the contribution of tendons, ligaments, and other soft tissues in the passive forces during distraction. Five fresh cadaveric specimens were tested using a distractor device to measure the applied forces upon gradual distraction of the intact joint. The subsequent step involved inserting a minuscule sensor into the joint capsule through a small incision, while preserving the integrity of tendons and ligaments, in order to accurately measure the fundamental intra-articular forces. A numerical model was also used to calculate the passive forces of tendons and ligaments. Before the separation of bones, the forces exerted by tendons and ligaments were relatively small compared to the capsule force, which accounted for approximately 92% of the total applied force. Contribution of tendons and ligaments, however, increased by further distraction. The passive force contribution by tendons at 2-mm distraction was determined less than 11%, whereas it reached up to 74% for the ligaments. The present study demonstrated that the ligament-capsule complex plays significant contribution in passive forces of thumb carpometacarpal joint during distraction.
引用
收藏
页码:1693 / 1705
页数:13
相关论文
共 44 条
[1]  
[Anonymous], 1993, Biomechanics: Mechanical Properties of Living Tissues
[2]   CONTACT AREAS IN THE THUMB CARPOMETACARPAL JOINT [J].
ATESHIAN, GA ;
ARK, JW ;
ROSENWASSER, MP ;
PAWLUK, RJ ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (03) :450-458
[3]  
BE V. G. F., 2015, THUMB CMC JOINT BIOM
[4]   A kinematic thumb model for the ACT hand [J].
Chang, Lillian Y. ;
Matsuoka, Yoky .
2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, :1000-1005
[5]   BIOMECHANICAL ANALYSIS OF STATIC FORCES IN THUMB DURING HAND FUNCTION [J].
COONEY, WP ;
CHAO, EYS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (01) :27-36
[6]   In vivo biomechanical behavior of the trapeziometacarpal joint in healthy and osteoarthritic subjects [J].
D'Agostino, Priscilla ;
Dourthe, Benjamin ;
Kerkhof, Faes ;
Van Lenthe, G. Harry ;
Stockmans, Filip ;
Vereecke, Evie E. .
CLINICAL BIOMECHANICS, 2017, 49 :119-127
[7]   A dynamic model of the hand with application in functional neuromuscular stimulation [J].
Esteki, A ;
Mansour, JM .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (03) :440-451
[8]   Estimation of joint contact pressure in the index finger using a hybrid finite element musculoskeletal approach [J].
Faudot, Barthelemy ;
Milan, Jean-Louis ;
Goislard de Monsabert, Benjamin ;
Le Corroller, Thomas ;
Vigouroux, Laurent .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (15) :1225-1235
[9]  
Fischer K. J., 2011, MRI BASED MODELING R
[10]   A method of examining the magnitude and origin of ''soft'' and ''hard'' tissue forces resisting limb lengthening [J].
Gardner, TN ;
Evans, M ;
Simpson, AHRW ;
Kyberd, PJ ;
Kenwright, J .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (05) :405-411