摘要
Purpose: To evaluate the trueness of five intraoral scanners on a fully edentulous model with seven implants. Materials and Methods: The study model was created from gypsum with seven implant analogs that were placed with 2-mm gingival height and a 0-degree angle at tooth sites 47, 45, 43, 31, 33, 35, and 37 (FDI system). The study model was scanned 10 times (n = 10) with five intraoral scanners (CS 3600, Emerald S, Primescan, Trios 3, and Trios 4). The study model was digitized with a high-resolution industrial desktop scanner, and the data were imported into reverse-engineering software to be used as the reference model. The trueness assessment was performed digitally with superimposition using the software. Linear measurements were calculated as the differences between the centers of the scan bodies on the study models vs the reference model. Volumetric deviations were calculated with root mean square values. Data obtained in the study were analyzed statistically using one-way analysis of variance and Tukey tests. A value of P < .05 was accepted as statistically significant. Results: In linear measurements, Trios 4 showed the best trueness results, followed by Trios 3, Emerald S, Primescan, and CS 3600. Trios 4 showed statistically higher trueness results than CS 3600 (P = .029). However, no statistically significant differences were found between groups in volumetric measurements (P < .05). Conclusions: All of the intraoral scanners used in the study showed favorable deviation values for an edentulous model with seven implants. Trios 4 showed the best trueness values. The latest generation of intraoral scanners can be used in full-arch implant impressions.
引用
收藏
页码:e1 / e12
页数:12
相关论文
共 26 条
  • [11] Izadi Alireza, 2018, J Contemp Dent Pract, V19, P974
  • [12] Jemt T, 1996, Int J Oral Maxillofac Implants, V11, P620
  • [13] In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques
    Kamimura, Emi
    Tanaka, Shinpei
    Takaba, Masayuki
    Tachi, Keita
    Baba, Kazuyoshi
    [J]. PLOS ONE, 2017, 12 (06):
  • [14] Kim S, 2006, INT J ORAL MAX IMPL, V21, P747
  • [15] Digital evaluation of the accuracy of impression techniques and materials in angulated implants
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    Ozcelik, Tuncer Burak
    Yagiz, Ayberk
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (12) : 1551 - 1559
  • [16] Effect of scan pattern on complete-arch scans with 4 digital scanners
    Latham, Jason
    Ludlow, Mark
    Mennito, Anthony
    Kelly, Abigail
    Evans, Zachary
    Renne, Walter
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01) : 85 - 95
  • [17] Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study
    Mangano, Francesco G.
    Veronesi, Giovanni
    Hauschild, Uli
    Mijiritsky, Eitan
    Mangano, Carlo
    [J]. PLOS ONE, 2016, 11 (09):
  • [18] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    [J]. BMC ORAL HEALTH, 2020, 20 (01)
  • [19] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Mangano, Francesco Guido
    Hauschild, Uli
    Veronesi, Giovanni
    Imburgia, Mario
    Mangano, Carlo
    Admakin, Oleg
    [J]. BMC ORAL HEALTH, 2019, 19 (1)
  • [20] Evaluation of the effect scan pattern has on the trueness and precision of six intraoral digital impression systems
    Mennito, Anthony S.
    Evans, Zachary P.
    Lauer, Abigail W.
    Patel, Ravi B.
    Ludlow, Mark E.
    Renne, Walter G.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2018, 30 (02) : 113 - 118