TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS

被引:2
作者
Issever, Dilara Seyma Alpkilic [1 ,2 ]
Deger, Sabire isler [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Prof Dr Cavit Orhan Tutengil Sk 4, TR-34116 Istanbul, Turkiye
关键词
AMBIENT LIGHT; ACCURACY; PRECISION;
D O I
10.11607/ijp.7824
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the trueness of five intraoral scanners on a fully edentulous model with seven implants. Materials and Methods: The study model was created from gypsum with seven implant analogs that were placed with 2-mm gingival height and a 0-degree angle at tooth sites 47, 45, 43, 31, 33, 35, and 37 (FDI system). The study model was scanned 10 times (n = 10) with five intraoral scanners (CS 3600, Emerald S, Primescan, Trios 3, and Trios 4). The study model was digitized with a high-resolution industrial desktop scanner, and the data were imported into reverse-engineering software to be used as the reference model. The trueness assessment was performed digitally with superimposition using the software. Linear measurements were calculated as the differences between the centers of the scan bodies on the study models vs the reference model. Volumetric deviations were calculated with root mean square values. Data obtained in the study were analyzed statistically using one-way analysis of variance and Tukey tests. A value of P < .05 was accepted as statistically significant. Results: In linear measurements, Trios 4 showed the best trueness results, followed by Trios 3, Emerald S, Primescan, and CS 3600. Trios 4 showed statistically higher trueness results than CS 3600 (P = .029). However, no statistically significant differences were found between groups in volumetric measurements (P < .05). Conclusions: All of the intraoral scanners used in the study showed favorable deviation values for an edentulous model with seven implants. Trios 4 showed the best trueness values. The latest generation of intraoral scanners can be used in full-arch implant impressions.
引用
收藏
页码:e1 / e12
页数:12
相关论文
共 26 条
[1]  
Alikhasi Marzieh, 2015, J Dent (Tehran), V12, P774
[2]   Evaluating the influence of ambient light on scanning trueness, precision, and time of intra oral scanner [J].
Arakida, Toshio ;
Kanazawa, Manabu ;
Iwaki, Maiko ;
Suzuki, Tetsuya ;
Minakuchi, Shunsuke .
JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (03) :324-329
[3]   The effect different substrates have on the trueness and precision of eight different intraoral scanners [J].
Dutton, Ethan ;
Ludlow, Mark ;
Mennito, Anthony ;
Kelly, Abigail ;
Evans, Zachary ;
Culp, Alexander ;
Kessler, Raymond ;
Renne, Walter .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (02) :204-218
[4]  
Ender A, 2013, INT J COMPUT DENT, V16, P11
[5]   In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions [J].
Ender, Andreas ;
Attin, Thomas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (03) :313-320
[6]   The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis [J].
Fluegge, Tabea ;
van der Meer, Wicher Joerd ;
Gonzalez, Beatriz Gimenez ;
Vach, Kirstin ;
Wismeijer, Daniel ;
Wang, Ping .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 :374-392
[7]   Accuracy of a Digital Impression System Based on Active Wavefront Sampling Technology for Implants Considering Operator Experience, Implant Angulation, and Depth [J].
Gimenez, Beatriz ;
Oezcan, Mutlu ;
Martinez-Rus, Francisco ;
Pradies, Guillermo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 :E54-E64
[8]   Intraoral Digital Impression Technique Compared to Conventional Impression Technique. A Randomized Clinical Trial [J].
Gjelvold, Bjorn ;
Chrcanovic, Bruno Ramos ;
Korduner, Eva-Karin ;
Collin-Bagewitz, Ingrid ;
Kisch, Jeno .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (04) :282-287
[9]   Effect of Software Version on the Accuracy of an Intraoral Scanning Device [J].
Haddadi, Yasser ;
Bahrami, Golnosh ;
Isidor, Flemming .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (04) :375-376
[10]   Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study [J].
Imburgia, Mario ;
Logozzo, Silvia ;
Hauschild, Uli ;
Veronesi, Giovanni ;
Mangano, Carlo ;
Mangano, Francesco Guido .
BMC ORAL HEALTH, 2017, 17