Contact lens sensor for ocular inflammation monitoring

被引:5
|
作者
Shi, Yuqi [1 ]
Wang, Lin [1 ]
Hu, Yubing [1 ]
Zhang, Yihan [1 ]
Le, Wenhao [1 ]
Liu, Guohui [1 ]
Tomaschek, Michael [1 ]
Jiang, Nan [2 ,3 ]
Yetisen, Ali K. [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, London SW7 2BU, England
[2] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Peoples R China
[3] Jinfeng Lab, Chongqing 401329, Peoples R China
来源
基金
英国工程与自然科学研究理事会;
关键词
Ascorbic acid; Contact lens sensor; Inflammatory dry eye disease; Ocular analysis; Reversible fluorescent sensor; Point -of -care diagnosis; Smartphone devices; REDUCED GRAPHENE OXIDE; DRY EYE DISEASE; ASCORBIC-ACID; VITAMIN-C; URIC-ACID; SURFACE; NANOCLUSTERS; LACTOFERRIN; DEVICE; PROBE;
D O I
10.1016/j.bios.2024.116003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Contact lens sensors have been emerging as point-of-care devices in recent healthcare developments for ocular physiological condition monitoring and diagnosis. Fluorescence sensing technologies have been widely applied in contact lens sensors due to their accuracy, high sensitivity, and specificity. As ascorbic acid (AA) level in tears is closely related to ocular inflammation, a fluorescent contact lens sensor incorporating a BSA-Au nanocluster (NC) probe is developed for in situ tear AA detection. The NCs are firstly synthesized to obtain a fluorescent probe, which exhibits high reusability through the quench/recover (KMnO4/AA) process. The probe is then encapsulated with 15 wt% of poly(vinyl alcohol) (PVA) and 1.5 wt% of citric acid (CA) film, and implemented on a closed microfluidic contact lens sensing region. The laser-ablated microfluidic channel in contact lens sensors allows for tear fluid to flow through the sensing region, enabling an in-situ detection of AA. Meanwhile, a smartphone application accompanied by a customized 3D printed readout box is developed for image caption and algorism to quantitative analysis of AA levels. The contact lens sensor is tested within the readout box and the emission signal is collected through the smartphone camera at room temperature with an achieved LOD of 0.178 mmol L-1 (0.0-1.2 mmol L-1). The operational and storage lifetime is also evaluated to characterize the sensor properties and resulted in 20 h and 10 days, respectively. The reusable AA contact lens sensor is promising to lead to an alternative accessible diagnostic method for ocular inflammation in point-of-care settings.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring
    Chiou, Jin-Chern
    Huang, Yu-Chieh
    Yeh, Guan-Ting
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (01)
  • [42] Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
    Leonardi, Matteo
    Pitchon, Elie M.
    Bertsch, Arnaud
    Renaud, Philippe
    Mermoud, Andre
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 433 - 437
  • [43] Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure
    Dou, Zhiqiang
    Tang, Jun
    Liu, Zhiduo
    Sun, Qigong
    Wang, Yang
    Li, Yamin
    Yuan, Miao
    Wu, Huijuan
    Wang, Yijun
    Pei, Weihua
    Chen, Hongda
    MICROMACHINES, 2021, 12 (02) : 1 - 12
  • [44] A Contact Lens Sensor System with a Micro-Capacitor for Wireless Intraocular Pressure Monitoring
    Huang, Yu-Chieh
    Yeh, Guan-Ting
    Yang, Tzu-Sen
    Chiou, Jin-Chern
    2013 IEEE SENSORS, 2013, : 203 - 206
  • [45] Influence of Ocular Dimensional Change on 24-Hour Intraocular Pressure Measurement With Contact Lens Sensor
    Tojo, Naoki
    Hayashi, Atsushi
    JOURNAL OF GLAUCOMA, 2019, 28 (09) : 808 - 810
  • [46] A bandage contact lens prevents extrusion of ocular contents
    Ramjiani, Vipul
    Fearnley, Thomas
    Tan, Jennifer
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (01): : 78 - 79
  • [47] Ocular symptoms associated with digital device use in contact lens and non-contact lens groups
    Meyer, Dawn
    Rickert, Martin
    Kollbaum, Pete
    CONTACT LENS & ANTERIOR EYE, 2021, 44 (01): : 42 - 50
  • [48] Lactoferrin as a biomarker of ocular diseases and contact lens discomfort
    Ponzini, E.
    Scotti, L.
    Zambon, A.
    Santambrogio, C.
    Grandori, R.
    Borghesi, A.
    Zeri, F.
    Tavazzi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2023, 46 (05):
  • [49] Improving ocular surface comfort in contact lens wearers
    Fernandez-Jimenez, Elena
    Diz-Arias, Elena
    Peral, Assumpta
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (03):
  • [50] Ocular response to environmental variations in contact lens wearers
    Lopez-de la Rosa, Alberto
    Martin-Montanez, Vicente
    Lopez-Miguel, Alberto
    Fernandez, Itziar
    Calonge, Margarita
    Gonzalez-Meijome, Jose M.
    Gonzalez-Garcia, Maria J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (01) : 60 - 70