Contact lens sensor for ocular inflammation monitoring

被引:5
|
作者
Shi, Yuqi [1 ]
Wang, Lin [1 ]
Hu, Yubing [1 ]
Zhang, Yihan [1 ]
Le, Wenhao [1 ]
Liu, Guohui [1 ]
Tomaschek, Michael [1 ]
Jiang, Nan [2 ,3 ]
Yetisen, Ali K. [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, London SW7 2BU, England
[2] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Peoples R China
[3] Jinfeng Lab, Chongqing 401329, Peoples R China
来源
基金
英国工程与自然科学研究理事会;
关键词
Ascorbic acid; Contact lens sensor; Inflammatory dry eye disease; Ocular analysis; Reversible fluorescent sensor; Point -of -care diagnosis; Smartphone devices; REDUCED GRAPHENE OXIDE; DRY EYE DISEASE; ASCORBIC-ACID; VITAMIN-C; URIC-ACID; SURFACE; NANOCLUSTERS; LACTOFERRIN; DEVICE; PROBE;
D O I
10.1016/j.bios.2024.116003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Contact lens sensors have been emerging as point-of-care devices in recent healthcare developments for ocular physiological condition monitoring and diagnosis. Fluorescence sensing technologies have been widely applied in contact lens sensors due to their accuracy, high sensitivity, and specificity. As ascorbic acid (AA) level in tears is closely related to ocular inflammation, a fluorescent contact lens sensor incorporating a BSA-Au nanocluster (NC) probe is developed for in situ tear AA detection. The NCs are firstly synthesized to obtain a fluorescent probe, which exhibits high reusability through the quench/recover (KMnO4/AA) process. The probe is then encapsulated with 15 wt% of poly(vinyl alcohol) (PVA) and 1.5 wt% of citric acid (CA) film, and implemented on a closed microfluidic contact lens sensing region. The laser-ablated microfluidic channel in contact lens sensors allows for tear fluid to flow through the sensing region, enabling an in-situ detection of AA. Meanwhile, a smartphone application accompanied by a customized 3D printed readout box is developed for image caption and algorism to quantitative analysis of AA levels. The contact lens sensor is tested within the readout box and the emission signal is collected through the smartphone camera at room temperature with an achieved LOD of 0.178 mmol L-1 (0.0-1.2 mmol L-1). The operational and storage lifetime is also evaluated to characterize the sensor properties and resulted in 20 h and 10 days, respectively. The reusable AA contact lens sensor is promising to lead to an alternative accessible diagnostic method for ocular inflammation in point-of-care settings.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Dual-band loop antenna on soft contact lens for wireless ocular physiological monitoring
    Luo, C. H.
    Ting, Si Han
    Jeng, Bo Ming
    Chen, Wen Shan
    Chiou, J. C.
    INNOVATION, COMMUNICATION AND ENGINEERING, 2014, : 133 - 135
  • [32] Effect of material and care system combination on subclinical inflammation of the ocular surface in soft contact lens wear
    Saliman, Noor Haziq
    Maldonado-Codina, Carole
    Morgan, Philip B.
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (04):
  • [33] Compliance with soft contact lens replacement schedules and associated contact lens-related ocular complications: The UCLA Contact Lens Study
    Yeung, Karen K.
    Forister, Julie F. Y.
    Forister, Eric F.
    Chung, Marisa Y.
    Han, Silvia
    Weissman, Barry A.
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2010, 81 (11) : 598 - 607
  • [34] Validity of the Results of a Contact Lens Sensor?
    Faschinger, Christoph
    Mossboeck, Georg
    JAMA OPHTHALMOLOGY, 2013, 131 (05) : 696 - 697
  • [35] A contact lens with an integrated lactate sensor
    Thomas, N.
    Laehdesmaeki, I.
    Parviz, B. A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 162 (01) : 128 - 134
  • [36] High-sensitive microfluidic contact lens sensor for intraocular pressure visualized monitoring
    Yuan, Miao
    Liu, Zhiduo
    Wu, Xiaoting
    Gou, Haoyang
    Zhang, Yugui
    Ning, Xin
    Li, Weijun
    Yao, Zhaohui
    Wang, Yijun
    Pei, Weihua
    Chen, Hongda
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 354
  • [37] Structurally coloured contact lens sensor for point-of-care ophthalmic health monitoring
    Wang, Yunlong
    Zhao, Qilong
    Du, Xuemin
    JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (16) : 3519 - 3526
  • [38] Scleral Lens Sensor for Ocular Electrolyte Analysis
    Yetisen, Ali K.
    Jiang, Nan
    Gonzalez, Carmen M. Castaneda
    Erenoglu, Zeynep Izlen
    Dong, Jie
    Dong, Xingchen
    Stoesser, Simon
    Brischwein, Martin
    Butt, Haider
    Cordeiro, Maria F.
    Jakobi, Martin
    Hayden, Oliver
    Koch, Alexander W.
    ADVANCED MATERIALS, 2020, 32 (06)
  • [39] Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Lam, David C. C.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 : 112 - 118
  • [40] Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Tafreshi, Ali
    Weinreb, Robert N.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (12) : 1534 - 1539