Contact lens sensor for ocular inflammation monitoring

被引:5
|
作者
Shi, Yuqi [1 ]
Wang, Lin [1 ]
Hu, Yubing [1 ]
Zhang, Yihan [1 ]
Le, Wenhao [1 ]
Liu, Guohui [1 ]
Tomaschek, Michael [1 ]
Jiang, Nan [2 ,3 ]
Yetisen, Ali K. [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, London SW7 2BU, England
[2] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Peoples R China
[3] Jinfeng Lab, Chongqing 401329, Peoples R China
来源
基金
英国工程与自然科学研究理事会;
关键词
Ascorbic acid; Contact lens sensor; Inflammatory dry eye disease; Ocular analysis; Reversible fluorescent sensor; Point -of -care diagnosis; Smartphone devices; REDUCED GRAPHENE OXIDE; DRY EYE DISEASE; ASCORBIC-ACID; VITAMIN-C; URIC-ACID; SURFACE; NANOCLUSTERS; LACTOFERRIN; DEVICE; PROBE;
D O I
10.1016/j.bios.2024.116003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Contact lens sensors have been emerging as point-of-care devices in recent healthcare developments for ocular physiological condition monitoring and diagnosis. Fluorescence sensing technologies have been widely applied in contact lens sensors due to their accuracy, high sensitivity, and specificity. As ascorbic acid (AA) level in tears is closely related to ocular inflammation, a fluorescent contact lens sensor incorporating a BSA-Au nanocluster (NC) probe is developed for in situ tear AA detection. The NCs are firstly synthesized to obtain a fluorescent probe, which exhibits high reusability through the quench/recover (KMnO4/AA) process. The probe is then encapsulated with 15 wt% of poly(vinyl alcohol) (PVA) and 1.5 wt% of citric acid (CA) film, and implemented on a closed microfluidic contact lens sensing region. The laser-ablated microfluidic channel in contact lens sensors allows for tear fluid to flow through the sensing region, enabling an in-situ detection of AA. Meanwhile, a smartphone application accompanied by a customized 3D printed readout box is developed for image caption and algorism to quantitative analysis of AA levels. The contact lens sensor is tested within the readout box and the emission signal is collected through the smartphone camera at room temperature with an achieved LOD of 0.178 mmol L-1 (0.0-1.2 mmol L-1). The operational and storage lifetime is also evaluated to characterize the sensor properties and resulted in 20 h and 10 days, respectively. The reusable AA contact lens sensor is promising to lead to an alternative accessible diagnostic method for ocular inflammation in point-of-care settings.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Influence of Tear Film and Contact Lens Osmolality on Ocular Comfort in Contact Lens Wear
    Stahl, Ulrike
    Willcox, Mark D. P.
    Naduvilath, Thomas
    Stapleton, Fiona
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (07) : 857 - 867
  • [22] 'Assessment of the Triggerfish® contact lens sensor for measurement of intra-ocular pressure variations' Response
    Leonardi, Matteo
    ACTA OPHTHALMOLOGICA, 2016, 94 (01) : E79 - E79
  • [23] Is There a Role for Inflammation in Contact Lens Discomfort?
    Willcox, Mark D. P.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (01): : 5 - 16
  • [24] Ocular surface health with contact lens wear
    Shovlin, Joseph P.
    CONTACT LENS & ANTERIOR EYE, 2013, 36 : S14 - S21
  • [25] Contact lens care and ocular surface homeostasis
    Efron, Nathan
    CONTACT LENS & ANTERIOR EYE, 2013, 36 : S9 - S13
  • [26] Contact lens based therapy for ocular cystinosis
    Chauhan, Anuj
    Adams, Chris
    Waldek, Stephen
    Elgott, Sara
    MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S30 - S30
  • [27] Ocular Surface Response in Contact Lens Wearers
    Muselier, A., Jr.
    Souchier, M.
    Mathieu, B.
    Gregoire, S.
    Nicot, F.
    Baudouin, F.
    Bretillon, L.
    Bron, A. M.
    Creuzot-Garcher, C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [28] Assessing contact lens associated ocular discomfort
    Jessee, CB
    Beuerman, RW
    Thompson, HW
    Steinemann, T
    Meyers, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 5179 - 5179
  • [29] THE CONTACT-LENS PATIENT AND OCULAR ALLERGIES
    DONSHIK, PC
    EHLERS, WH
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 1991, 31 (02) : 133 - 145
  • [30] Monitoring ocular disease via optical nanostructures potentially applicable to corneal contact lens products
    AlQattan, Bader
    Elsherif, Mohamed
    Alam, Fahad
    Butt, Haider
    NPG ASIA MATERIALS, 2024, 16 (01)