Air-side fouling of finned heat exchangers: Part 1, review and proposed test protocol

被引:6
作者
Inamdar, Harshad, V [1 ]
Groll, Eckhard A. [2 ]
Weibel, Justin A. [2 ]
Garimella, Suresh, V [2 ]
机构
[1] Rheem Mfg Co, Ft Smith, AR 72908 USA
[2] Purdue Univ, Cooling Technol Res Ctr, Sch Mech Engn, W Lafayette, IN 47907 USA
关键词
Particulate fouling; Finned heat exchanger; Air-side fouling; Test protocol; PRESSURE-DROP; DEPOSITION; PERFORMANCE; IMPACT;
D O I
10.1016/j.ijrefrig.2023.02.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-side fouling of heat exchangers has received much attention in the literature through both experimental and modeling studies. However, no standards currently exist that define a test procedure to experimentally foul heat exchangers and evaluate their performance in a fouled condition. This is evidenced by the variation in test procedures, fouling agents, metrics, and operating conditions reported. Based on a detailed review of past experiments, a standardized, repeatable test procedure is proposed that allows cross-comparison of data acquired in different laboratory facilities. The procedure generates time-resolved information on foulant buildup on the finned heat exchanger and the consequent impact on heat exchanger performance. Various fouling agents used in the literature and fouling deposits observed on field-installed heat exchangers are compared, and a representative fouling agent is recommended. A method is proposed to quantify heat exchanger fouling and metrics identified to quantify heat exchanger performance before and after fouling. This is the first of two companion papers on an experimental investigation of air-side fouling of heat exchangers. The companion paper presents experimental data obtained by implementation of the proposed procedure to investigate fouling of a finned microchannel heat exchanger.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 33 条
[1]   Characteristics of air-side particulate fouling materials in finned-tube heat exchangers of air conditioners [J].
Ahn, YC ;
Lee, JK .
PARTICULATE SCIENCE AND TECHNOLOGY, 2005, 23 (03) :297-307
[2]   An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners [J].
Ahn, YC ;
Cho, JM ;
Shin, HS ;
Hwang, YJ ;
Lee, CG ;
Lee, JK ;
Lee, HU ;
Kang, TW .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 20 (05) :873-877
[3]   Evaporator air-side fouling: Effect on performance of room air conditioners and impact on indoor air quality [J].
Ali, Ahmed Hamza H. ;
Ismail, Ibrahim M. .
HVAC&R RESEARCH, 2008, 14 (02) :209-219
[4]  
[Anonymous], 2002, Doctoral dissertation
[5]  
[Anonymous], 2014, ISO Standard 5011
[6]  
[Anonymous], 2002, SAE International Standard J726
[7]  
ANSI/ASHRAE Standard, 2012, Method of Testing General Ventilation Air-Cleaning Devices For Removal Efficiency By Particle Size, V52, P2
[8]   Experimental Analysis of the Effects of Particulate Fouling on Heat Exchanger Heat Transfer and Air-Side Pressure Drop for a Hybrid Dry Cooler [J].
Bell, Ian H. ;
Groll, Eckhard A. ;
Koenig, Holger .
HEAT TRANSFER ENGINEERING, 2011, 32 (3-4) :264-271
[9]   Air-side particulate fouling of microchannel heat exchangers: Experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger [J].
Bell, Ian H. ;
Groll, Eckhard A. .
APPLIED THERMAL ENGINEERING, 2011, 31 (05) :742-749
[10]  
Boll R.H., 1961, Transactions of the American Society of Mechanical Engineers, Journal of Engineering for Power, series A, V83, P451, DOI DOI 10.1115/1.3673236