摘要
An understanding of the biomechanical characteristics and configuration of flexible and locked plating in order to provide balance stability and flexibility of implant fixation will help to construct and promote fast bone healing. The relationship between applied loading and implantation configuration for best bone healing is still under debate. This study aims to investigate the relationship between implant strength, working length, and interfragmentary strain (eIFM) on implant stability for femoral midshaft transverse fractures. The transverse fracture was fixed with a fragment locking compression plate (LCP) system. Finite element analysis was performed and subsequently characterised based on compression loading (600 N up to 900 N) and screw designs (conventional and locking) with different penetration depths (unicortical and bicortical). Strain theory was used to evaluate the stability of the model. The correlation of screw configuration with screw type shows a unicortical depth for both types (p < 0.01) for 700 N and 800 N loads and (p < 0.05) for configurations 134 and 124. Interfragmentary strain affected only the 600 N load (p < 0.01) for the bicortical conventional type (group BC), and the screw configurations that were influenced were 1234 and 123 (p < 0.05). The low steepness of the slope indicates the least eIFM for the corresponding biomechanical characteristic in good-quality stability. A strain value of =2% promotes callus formation and is classified as absolute stability, which is the minimum required value for the induction of callus and the maximum value that allows bony bridging. The outcomes have provided the correlation of screw configuration in femoral midshaft transverse fracture implantation which is important to promote essential primary stability.
引用
收藏
页数:21
相关论文
共 55 条
[11]   A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests [J].
Eberle, S. ;
Gerber, C. ;
von Oldenburg, G. ;
Hoegel, F. ;
Augat, P. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H10) :1141-1152
[12]   Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[13]   Achievable accuracy of hip screw holding power estimation by insertion torque measurement [J].
Erani, Paolo ;
Baleani, Massimiliano .
CLINICAL BIOMECHANICS, 2018, 52 :57-65
[14]  
Fernandes MG, 2016, International Journal of Materials Engineering Innovation, V7, P130, DOI [10.1504/ijmatei.2016.079556, 10.1504/IJMATEI.2016.079556, DOI 10.1504/IJMATEI.2016.079556]
[15]   Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis [J].
Fitzpatrick, Daniel C. ;
Doornink, Josef ;
Madey, Steven M. ;
Bottlang, Michael .
CLINICAL BIOMECHANICS, 2009, 24 (02) :203-209
[16]   Effects of the bone-plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone [J].
Fouad, H. .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) :783-789
[17]   Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws [J].
Gautschi, Oliver P. ;
Schatlo, Bawarjan ;
Schaller, Karl ;
Tessitore, Enrico .
NEUROSURGICAL FOCUS, 2011, 31 (04)
[18]   Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws [J].
Gefen, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (03) :311-322
[19]   Biocompatibility of Ti-alloys for long-term implantation [J].
Gepreel, Mohamed Abdel-Hady ;
Niinomi, Mitsuo .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 20 :407-415
[20]   A comparative study of orthotropic and isotropic bone adaptation in the femur [J].
Geraldes, Diogo M. ;
Phillips, Andrew T. M. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (09) :873-889