Stability Analysis of Plate-Screw Fixation for Femoral Midshaft Fractures

被引:3
作者
Basirom, Izzawati [1 ]
Daud, Ruslizam [1 ]
Ijaz, Muhammad Farzik [2 ]
Rojan, Mohd Afendi [1 ]
Basaruddin, Khairul Salleh [1 ]
机构
[1] Univ Malaysia Perlis, Fac Mech Engn Technol, Fracture & Damage Mech FDM, Arau 02600, Perlis, Malaysia
[2] King Saud Univ, Coll Engn, Mech Engn Dept, POB 800, Riyadh 11421, Saudi Arabia
关键词
Implant stability; interfragmentary strain; transverse fracture; screw configuration; COMPRESSION PLATE; DENTAL IMPLANT; BONE; TITANIUM; GAP; OPTIMIZATION; BIOMECHANICS; INTERFACE; EVOLUTION; ALLOYS;
D O I
10.3390/ma16175958
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An understanding of the biomechanical characteristics and configuration of flexible and locked plating in order to provide balance stability and flexibility of implant fixation will help to construct and promote fast bone healing. The relationship between applied loading and implantation configuration for best bone healing is still under debate. This study aims to investigate the relationship between implant strength, working length, and interfragmentary strain (eIFM) on implant stability for femoral midshaft transverse fractures. The transverse fracture was fixed with a fragment locking compression plate (LCP) system. Finite element analysis was performed and subsequently characterised based on compression loading (600 N up to 900 N) and screw designs (conventional and locking) with different penetration depths (unicortical and bicortical). Strain theory was used to evaluate the stability of the model. The correlation of screw configuration with screw type shows a unicortical depth for both types (p < 0.01) for 700 N and 800 N loads and (p < 0.05) for configurations 134 and 124. Interfragmentary strain affected only the 600 N load (p < 0.01) for the bicortical conventional type (group BC), and the screw configurations that were influenced were 1234 and 123 (p < 0.05). The low steepness of the slope indicates the least eIFM for the corresponding biomechanical characteristic in good-quality stability. A strain value of =2% promotes callus formation and is classified as absolute stability, which is the minimum required value for the induction of callus and the maximum value that allows bony bridging. The outcomes have provided the correlation of screw configuration in femoral midshaft transverse fracture implantation which is important to promote essential primary stability.
引用
收藏
页数:21
相关论文
共 55 条
[1]   Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[2]  
Alemdar C, 2015, ACTA ORTHOP BELG, V81, P523
[3]  
Bagheri ZS, 2017, EXPERIMENTAL METHODS IN ORTHOPAEDIC BIOMECHANICS, P49, DOI 10.1016/B978-0-12-803802-4.00004-4
[4]   Unlocked and locked elastic stable intramedullary nailing in an ovine tibia fracture model: A biomechanical study [J].
Berger, Leopold ;
Fischerauer, Stefan ;
Weiss, Barbara ;
Celarek, Anna ;
Castellani, Christoph ;
Weinberg, Annelie-Martina ;
Tschegg, Elmar .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 40 :267-274
[5]   Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants [J].
Bitter, Thom ;
Khan, Imran ;
Marriott, Tim ;
Lovelady, Elaine ;
Verdonschot, Nico ;
Janssen, Dennis .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 :616-623
[6]   Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate [J].
Chao, Peini ;
Conrad, Bryan P. ;
Lewis, Daniel D. ;
Horodyski, MaryBeth ;
Pozzi, Antonio .
BMC VETERINARY RESEARCH, 2013, 9
[7]   Influence of Deformation and Stress between Bone and Implant from Various Bite Forces by Numerical Simulation Analysis [J].
Cheng, Hsin-Chung ;
Peng, Boe-Yu ;
Chen, May-Show ;
Huang, Chiung-Fang ;
Lin, Yi ;
Shen, Yung-Kang .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[8]   A simplified application (APP) for the parametric design of screw-plate fixation of bone fractures [J].
Chung, Chen-Yuan .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 :642-648
[9]   Bioactive materials driven primary stability on titanium biocomposites [J].
Dantas, T. A. ;
Abreu, C. S. ;
Costa, M. M. ;
Miranda, G. ;
Silva, F. S. ;
Dourado, N. ;
Gomes, J. R. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 77 :1104-1110
[10]   Mechanical stability of custom-made implants: Numerical study of anatomical device and low elastic Young's modulus alloy [J].
Didier, P. ;
Piotrowski, B. ;
Fischer, M. ;
Laheurte, P. .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 74 :399-409