Carbon Dioxide Concentration Estimation in Nonuniform Temperature Fields Based on Single-Pass Tunable Diode Laser Absorption Spectroscopy

被引:4
|
作者
Choi, Junggon [1 ]
Bong, Cheolwoo [1 ]
Yoo, Jihyung [2 ]
Bak, Moon Soo [1 ,3 ,4 ]
机构
[1] Sungkyunkwan Univ, Sch Mech Engn, Suwon 16419, Gyeonggi Do, South Korea
[2] Hanyang Univ, Dept Automot Engn, Seoul, South Korea
[3] Sungkyunkwan Univ, Dept Smart Fab Technol, Suwon 16419, Gyeonggi Do, South Korea
[4] Sungkyunkwan Univ, Nat Sci Campus Engn Bldg 1,Room 21313,2066 Seobu R, Suwon 16419, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Carbon dioxide; tunable diode laser absorption spectroscopy; TDLAS; carbon emission; machine learning; digital twin; EMISSION CHARACTERISTICS; GAS; CO2; COMBUSTION; TDLAS; SENSOR; RECONSTRUCTION; TECHNOLOGIES; PERFORMANCE; SEPARATION;
D O I
10.1177/00037028231191782
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We propose a novel technique to accurately predict carbon dioxide (CO2) concentrations even in flow fields with temperature gradients based on a single laser path absorption spectrum measurement and machine learning. Concentration measurements in typical tunable diode laser absorption spectroscopy are based on a ratio of two integrated absorbances, each from a spectral line with different temperature dependence. However, the inferred concentrations can deviate significantly from the actual concentrations in the presence of temperature gradients. Furthermore, it is also difficult to find an analytical expression to compensate for the effect of nonuniform temperature profiles on concentration measurements. In this study, the entire absorption feature was considered since its shape and peak intensities vary with temperature and concentration. Specifically, a predictive model is obtained in a data-driven manner that can identify and compensate for the effect of a non -uniform temperature field on the spectrum. Despite a very detailed understanding of the CO2 absorption spectrum, it is nearly impossible to collect sufficient spectra for model acquisition by varying all temperature gradient conditions. Therefore, the model was obtained using only simulated data, much like the concept of a "digital twin". Finally, the predictive performance of the acquired model was verified using experimental data. In all test cases, the predictive performance of the model was superior to that of the two-line method. Additionally, a gradient-weighted regression activation mapping analysis confirmed that the model utilizes both the peak intensities as well as the change in the shape of absorption lines for prediction.
引用
收藏
页码:1194 / 1205
页数:12
相关论文
共 50 条
  • [1] OXYGEN CONCENTRATION AND TEMPERATURE SIMULTANEOUS MEASUREMENT BASED ON TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY
    Zhang, Chun-Xiao
    Wang, Fei
    Zheng, Qi-Ming
    Yan, Jianhua
    Chi, Yong
    Cen, Ke-fa
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 2, 2009, : 147 - 150
  • [2] Tunable Diode Laser Absorption Spectroscopy Based Temperature Measurement with a Single Diode Laser Near 1.4 μm
    Liu, Xiaonan
    Ma, Yufei
    SENSORS, 2022, 22 (16)
  • [3] Temperature measurements based on tunable diode laser absorption spectroscopy
    Xu Zhen-Yu
    Liu Wen-Qing
    Liu Jian-Guo
    He Jun-Feng
    Yao Lu
    Ruan Jun
    Chen Jiu-Ying
    Li Han
    Yuan Song
    Geng Hui
    Kan Rui-Feng
    ACTA PHYSICA SINICA, 2012, 61 (23)
  • [4] Carbon Monoxide Measurement at Elevated Temperature Based on Tunable Diode Laser Absorption Spectroscopy
    Guo Yan-Lin
    Huang Xiao
    Hong Yi
    Dong Jun-Guo
    Gao Wei
    Li Mei
    Huang Zheng-Xu
    Fu Zhong
    Cheng Ping
    Zhou Zhen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (08) : 1247 - 1254
  • [5] Monitoring the Flux of Carbon Dioxide Gas with Tunable Diode Laser Absorption Spectroscopy
    Song Xue-mei
    Liu Jian-guo
    Zhang Yu-jun
    Zeng Zong-yong
    He Ying
    Cui Yi-ben
    Chen Yin
    Tian Yong-zhi
    Zhang Liang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (01) : 184 - 187
  • [6] Monitoring of Oxygen Concentration Based on Tunable Diode Laser Absorption Spectroscopy
    Zhang Shuai
    Dong Feng-zhong
    Zhang Zhi-rong
    Wang Yu
    Kan Rui-feng
    Zhang Yu-jun
    Liu Jian-guo
    Liu Wen-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2593 - 2596
  • [7] Effect of temperature on methane gas concentration by tunable diode laser absorption spectroscopy
    Zhao, Yanjie
    Wei, Yubin
    Li, Yanfang
    Zhang, Tingting
    Wang, Chang
    Liu, Tongyu
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [8] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Yu, Xilong
    Li, Fei
    Chen, Lihong
    Zhang, Xinyu
    ACTA MECHANICA SINICA, 2010, 26 (01) : 147 - 149
  • [9] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong YuFei LiLihong ChenXinyu Zhang Key Laboratory of High Temperature Gas Dynamics Institute of MechanicsChinese Academy of Sciences BeijingChina
    Acta Mechanica Sinica, 2010, 26 (01) : 147 - 149
  • [10] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong Yu
    Fei Li
    Lihong Chen
    Xinyu Zhang
    Acta Mechanica Sinica, 2010, 26 : 147 - 149