A two-staged adsorption/thermal desorption GC/MS online system for monitoring volatile organic compounds

被引:2
作者
Wang, Wenjun [1 ]
Chen, Huan [2 ]
Zhu, Wei [3 ]
Gong, Zhengjun [4 ,5 ]
Yin, Hui [6 ]
Gao, Chao [7 ]
Zhu, Anni [1 ]
Wang, Dongmei [4 ]
机构
[1] Chengdu Agr Coll, Sch Leisure Tourism, Chengdu 611130, Peoples R China
[2] Clemson Univ, Biogeochem & Environm Qual Res Grp, Clemson, SC 29442 USA
[3] Shimadzu China Co LTD, Sichuan Branch, Chengdu 610031, Peoples R China
[4] Southwest Jiaotong Univ, Fac Geosci & Environm Engn, Chengdu 611756, Peoples R China
[5] State Prov Joint Engn Lab Spatial Informat Technol, Chengdu 610756, Peoples R China
[6] Sichuan Shengshi Technol Co LTD, Chengdu 610031, Peoples R China
[7] Hebei Sailhero Environm Protect High Tech Co LTD, Shijiazhuang 050035, Peoples R China
基金
中国国家自然科学基金;
关键词
VOCs; GC; MS; Online monitoring; Two-staged adsorption; thermal desorption; Thermoelectric coolers; Heart cutting; CHROMATOGRAPHY-MASS SPECTROMETRY; FLAME IONIZATION DETECTION; MULTIBED SORPTION TRAP; HEALTH-RISK ASSESSMENT; GAS-CHROMATOGRAPHY; COMPOUNDS VOCS; VALIDATION;
D O I
10.1007/s10661-023-11431-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Real-time online monitoring of volatile organic compounds (VOCs) in ambient air is crucial for timely and effective human health protection. Here, we developed an innovative, automated two-staged adsorption/thermal desorption gas chromatography/mass spectrometry (GC/MS) system for real-time online monitoring of 117 regulated volatile organic compounds (VOCs). This system comprised a sampling unit, water management trap, two-staged adsorption/thermal desorption unit, thermoelectric coolers (TECs), and a commercial GC/MS system. By implementing a micro-purge-and-trap (MP & T) step and a two-staged adsorption/thermal desorption unit, the presence of interfering substances was effectively minimized. The utilization of a heart-cutting GC, combined with a single MS detector, facilitated the precise separation and detection of 117 C-2-C-12 VOCs, while circumventing the identification and coelution challenges commonly associated with traditional GC-FID or GC-FID/MS methods. The performance of our newly developed online system was meticulously optimized and evaluated using standard gas mixtures. Under optimal conditions, we achieved impressive results, with R-2 values & GE; 0.9946 for the standard linear curves of all 117 VOCs, demonstrating a precision (RSD) ranging from 0.2% to 6.4%. When applied in the field monitoring, the concentration drifts for 10 ppbv standard gas mixtures were 0.01-5.64% within 24 h. Our study developed a system for online monitoring of 117 atmospheric VOCs with relatively high accuracy and robustness.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Determination of N,N-Dimethylformamide in Ambient Air Using Adsorption Sampling and Thermal Desorption with GC/MS Analysis
    Seo, Young-Kyo
    Hwang, Yoon-Jung
    Lee, Soon-Jin
    Lee', Min -Do
    Flan, Jin-Seok
    Baek, Sung-Ok
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2010, 26 (04) : 357 - 366
  • [42] Development and validation of a method for air-quality and nuisance odors monitoring of volatile organic compounds using multi-sorbent adsorption and gas chromatography/mass spectrometry thermal desorption system
    Ribes, Alejandra
    Carrera, Guillem
    Gallego, Eva
    Roca, Xavier
    Berenguer, Ma Jose
    Guardino, Xavier
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) : 44 - 55
  • [43] Real-Time and Online Monitoring of Hazardous Volatile Organic Compounds in Environmental Water by an Unmanned Shipborne Mass Spectrometer System
    Zhang, Jianfeng
    Huang, Wenjie
    Wu, Riwei
    Yan, Zhiqi
    Tan, Guobin
    Zhu, Chenghui
    Gao, Wei
    Hu, Bin
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (49) : 20864 - 20870
  • [44] Optimization of Headspace SPME GC x GC-TOF/MS Analysis of Volatile Organic Compounds in Edible Oils by Central Composite Design for Adulteration Detection of Edible Oil
    Sun, Yu
    Dou, Xinjing
    Yue, Xiaofeng
    Yu, Li
    Zhan, Liangxiao
    Li, Ji
    Li, Peiwu
    FOOD ANALYTICAL METHODS, 2020, 13 (06) : 1328 - 1336
  • [45] Determination of volatile organic compounds in wallpaper using headspace-spme and GC-MS
    Huang, YD
    Zhao, ST
    Hu, B
    Wang, D
    Ning, ZW
    Zhu, ZG
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2090 - 2093
  • [46] The application of isotopically labeled analogues for the determination of small organic compounds by GC/MS with selected ion monitoring
    Caban, Magda
    Stepnowski, Piotr
    ANALYTICAL METHODS, 2020, 12 (30) : 3854 - 3864
  • [47] Process sampling module coupled with purge and trap-GC-FID for in situ auto-monitoring of volatile organic compounds in wastewater
    Liu, Hsin-Wang
    Liu, Yung-Tsun
    Wu, Bei-Zen
    Nian, Hung-Chi
    Chen, Hsing-Jung
    Chiu, Kong-Hwa
    Lo, Jiunn-Guang
    TALANTA, 2009, 80 (02) : 903 - 908
  • [48] Comparison of the volatile organic compounds present in human odor using SPME-GC/MS
    Curran, AM
    Rabin, SI
    Prada, PA
    Furton, KG
    JOURNAL OF CHEMICAL ECOLOGY, 2005, 31 (07) : 1607 - 1619
  • [49] Comparison of the Volatile Organic Compounds Present in Human Odor Using Spme-GC/MS
    Allison M. Curran
    Scott I. Rabin
    Paola A. Prada
    Kenneth G. Furton
    Journal of Chemical Ecology, 2005, 31 : 1607 - 1619
  • [50] Development of a sensitive thermal desorption GC-MS method using selective ion monitoring for a wide range of VOCs
    Jia, C
    Batterman, S
    Chernyak, S
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2194 - 2199