Review of sub-synchronous interaction in wind integrated power systems: classification, challenges, and mitigation techniques

被引:22
|
作者
Verma, Neevatika [1 ]
Kumar, Narendra [1 ]
Gupta, Saket [1 ,5 ]
Malik, Hasmat [2 ,4 ]
Garcia Marquez, Fausto Pedro [3 ]
机构
[1] Delhi Technol Univ, Dept Elect Engn, Delhi 110042, India
[2] UTM, Fac Elect Engn, Dept Elect Power Engn, Johor Baharu 81310, Malaysia
[3] Univ Castilla La Mancha, Ingenium Res Grp, Ciudad Real 13071, Spain
[4] Graphic Era Deemed Be Univ, Dept Elect Engn, Dehra Dun 248002, India
[5] Bharati Vidyapeeths Coll Engn, Instrumentat & Control Engn Dept, New Delhi 110056, India
关键词
Damping controller; Doubly fed induction generator (DFIG); Series compensations; Sub-synchronous interactions (SSI); Sub-synchronous resonance (SSR); FED INDUCTION GENERATOR; SUBSYNCHRONOUS CONTROL INTERACTION; FEEDBACK LINEARIZATION; TORSIONAL INTERACTION; SERIES COMPENSATION; TRANSFER CAPABILITY; RESONANCE ANALYSIS; CONTROLLER-DESIGN; DAMPING CONTROL; SSR MITIGATION;
D O I
10.1186/s41601-023-00291-0
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Emerging sub-synchronous interactions (SSI) in wind-integrated power systems have added intense attention after numerous incidents in the US and China due to the involvement of series compensated transmission lines and power electronics devices. SSI phenomenon occurs when two power system elements exchange energy below the synchronous frequency. SSI phenomenon related to wind power plants is one of the most significant challenges to maintaining stability, while SSI phenomenon in practical wind farms, which has been observed recently, has not yet been described on the source of conventional SSI literature. This paper first explains the traditional development of SSI and its classification as given by the IEEE, and then it proposes a classification of SSI according to the current research status, reviews several mitigation techniques and challenges, and discusses analysis techniques for SSI. The paper also describes the effect of the active damping controllers, control scheme parameters, degree of series compensation, and various techniques used in wind power plants (WPPs). In particular, a supplementary damping controller with converter controllers in Doubly Fed Induction Generator based WPPs is briefly pronounced. This paper provides a realistic viewpoint and a potential outlook for the readers to properly deal with SSI and its mitigation techniques, which can help power engineers for the planning, economical operation, and future expansion of sustainable development.
引用
收藏
页数:26
相关论文
共 50 条
  • [31] Case Study and Mechanism Analysis of Sub-Synchronous Oscillation in Wind Power Plants
    Li Yunhong
    Liu Hui
    Li Yu
    Xie Xiaorong
    Liu Shaoyu
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [32] Sub-synchronous control interaction in power grids including doubly fed induction generator based wind turbines
    Azizi, Amir Hossein
    Rahimi, Mohsen
    IET RENEWABLE POWER GENERATION, 2022, 16 (15) : 3197 - 3215
  • [33] Mitigation of Sub-synchronous Resonance in Doubly Fed Induction Generator Based Wind Energy System
    Ratna, Ankita
    Pachauri, Rupendra Kumar
    Chauhan, Yogesh K.
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [34] Designing a Robust Controller to Damp Sub-synchronous Oscillations in Power Systems
    Gamage, C. Mahawala
    Wadduwage, D. Prasad
    MERCON 2020: 6TH INTERNATIONAL MULTIDISCIPLINARY MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON), 2020, : 566 - 571
  • [35] Concept of Modal Repulsion for Examining the Sub-Synchronous Oscillations in Power Systems
    Du, Wenjuan
    Wang, Yang
    Wang, Haifeng
    Fu, Qiang
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (04) : 4614 - 4624
  • [36] Studies of Sub-Synchronous Oscillations in Large-Scale Wind Farm Integrated System
    Yue, Liu
    Hang, Mend
    2017 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION (ESMA2017), VOLS 1-4, 2018, 108
  • [37] Characteristics of sub-synchronous interaction among D-PMSG-based wind turbines
    Liu, Yuming
    Wang, Long
    Sun, Haishun
    Huang, Biyue
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1434 - 1438
  • [38] A Sub-Synchronous Oscillation Suppression Strategy for Doubly Fed Wind Power Generation System
    Meng, Fanyi
    Sun, Dongyang
    Zhou, Kai
    Wu, Jun
    Zhao, Fanqi
    Sun, Li
    IEEE ACCESS, 2021, 9 : 83482 - 83498
  • [39] A Study on The Impact of Wind Farm Spatial Distribution on Power System Sub-Synchronous Oscillations
    Wu, Meng
    Xie, Le
    Cheng, Lin
    Sun, Rongfu
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (03) : 2154 - 2162
  • [40] A review of recent studies on the mechanisms and analysis methods of sub-synchronous oscillation in wind farms
    Wang, Chenggen
    Zhou, Qian
    Gao, Shuning
    Luo, Jia
    Diao, Junchao
    Zhao, Haoran
    Bu, Jing
    2018 ASIA CONFERENCE ON ENERGY AND ENVIRONMENT ENGINEERING (ACEEE 18), 2018, 133