Numerical investigation and optimization of a novel hybrid solar chimney for air pollution mitigation and clean electricity generation

被引:6
作者
Hachicha, Ahmed Amine [1 ,2 ]
Abo-Zahhad, Essam M. [2 ,3 ]
Oh, Sahuck [4 ]
Issa, Salah [2 ]
Rahman, S. M. A. [1 ,2 ]
机构
[1] Univ Sharjah, Sustainable & Renewable Energy Engn Dept, POB 27272, Sharjah, U Arab Emirates
[2] Univ Sharjah, Res Inst Sci & Engn, Sustainable Energy & Power Syst Res Ctr, Sharjah, U Arab Emirates
[3] Aswan Univ, Fac Energy Engn, Mech Power Engn Dept, Aswan 81528, Egypt
[4] Korea Aerosp Univ, Sch Aerosp & Mech Engn, Goyang, South Korea
基金
新加坡国家研究基金会;
关键词
Filter -equipped solar chimney; Air purification; Electricity generation; Air filter; Optimization; CFD; FRESH-WATER GENERATION; POWER-PLANT; HEAT-TRANSFER; COOLING-TOWER; UPDRAFT TOWER; DESIGN; FLOW; TEMPERATURE; STRATEGY; WALL;
D O I
10.1016/j.applthermaleng.2023.120271
中图分类号
O414.1 [热力学];
学科分类号
摘要
With the increasing energy demands and environmental concerns, more attention is paid to sustainable and renewable energy solutions. This work proposes a hybrid filter-equipped solar chimney power plant to purify the outdoor air and generate electricity simultaneously. A two-dimensional numerical model that incorporates the filter model, the turbine model, and a two-band radiation model is developed to study and optimize the per-formance of the novel system. Both chimney and filter models are validated with numerical and experimental data from the literature. The impact of the air filter on the thermal performance and fluid flow characteristics is investigated by varying the weather parameters. Moreover, multi-objective optimization of the filter position is carried out using response surface methodology. The findings indicated that placing the air filter closer to the collector inlet gives the best configuration. The results of a case study in Sharjah showed that the optimized hybrid filter-equipped solar chimney could produce around 28.3 kW of electricity while purifying the outdoor air at a rate of 447.6 m3/s. The proposed hybrid system has comparable capabilities to uncombined systems with only 6 % power reduction and less than 35 % of clean air at higher filter efficiency.
引用
收藏
页数:14
相关论文
共 56 条
[1]  
ANSYS, 2021, ANSYS FLUENT REL 202
[2]   Thermal and technical analyses of solar chimneys [J].
Bernardes, MAD ;
Voss, A ;
Weinrebe, G .
SOLAR ENERGY, 2003, 75 (06) :511-524
[3]   ON THE EXPERIMENTAL ATTAINMENT OF OPTIMUM CONDITIONS [J].
BOX, GEP ;
WILSON, KB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1951, 13 (01) :1-45
[4]   Urban-scale SALSCS, Part I: Experimental Evaluation and Numerical Modeling of a Demonstration Unit [J].
Cao, Qingfeng ;
Kuehn, Thomas H. ;
Shen, Lian ;
Chen, Sheng-Chieh ;
Zhang, Ningning ;
Huang, Yu ;
Cao, Junji ;
Pui, David Y. H. .
AEROSOL AND AIR QUALITY RESEARCH, 2018, 18 (11) :2865-2878
[5]   A Concept of a Novel Solar-Assisted Large-Scale Cleaning System (SALSCS) for Urban Air Remediation [J].
Cao, Qingfeng ;
Pui, David Y. H. ;
Lipinski, Wojciech .
AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (01) :1-10
[6]   A review of chemical heat pumps, thermodynamic cycles and thermal energy storage technologies for low grade heat utilisation [J].
Chan, C. W. ;
Ling-Chin, J. ;
Roskilly, A. P. .
APPLIED THERMAL ENGINEERING, 2013, 50 (01) :1257-1273
[7]   Numerical analysis of heat transfer in a passive solar composite wall with porous absorber [J].
Chen, Wei ;
Liu, Wei .
APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) :1251-1258
[8]   Analysis of heat transfer and flow in the solar chimney with the sieve-plate thermal storage beds packed with phase change capsules [J].
Chen, Wei ;
Chen, Wei .
RENEWABLE ENERGY, 2020, 157 (157) :491-501
[9]   Study on optimizing design of solar chimney for natural ventilation and smoke exhaustion [J].
Cheng, Xudong ;
Shi, Long ;
Dai, Peng ;
Zhang, Guomin ;
Yang, Hui ;
Li, Jie .
ENERGY AND BUILDINGS, 2018, 170 :145-156
[10]  
Dhari A., 2013, INT J ENG ADV TECHNO, V2, P1, DOI DOI 10.1016/J.RSER.2010.04.018