Factors Influencing the Time of Intubation Using C-MAC D-Blade? Video Laryngoscope: An Observational Cross-Sectional Study

被引:1
作者
Gayathri, Balasubramaniam [1 ]
Mani, Karthik [1 ]
Vishak, Manoj [1 ]
John, Joy [2 ]
Srinivasan, Raghul G. [3 ]
Mirunalini, Gunaseelan [1 ]
机构
[1] SRM Med Coll Hosp & Res Ctr, Anaesthesiol, Chennai, India
[2] Dr Rela Inst & Med Ctr, Anaesthesiol, Chennai, India
[3] SRM Inst Sci & Technol, Ctr Stat, Chennai, India
关键词
c -mac d -blade; video laryngoscope; intubation; resident; competency; curvature; ENDOTRACHEAL INTUBATION;
D O I
10.7759/cureus.34050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeC-MAC D-Blade (R) (Karl Storz, Tuttlingen, Germany) video laryngoscope (VL) has proved to be of immense utility in difficult intubation. But unfortunately, in an urgent situation, the predictable correct curvature of the endotracheal tube for effortless intubation is not met. We hypothesized that expertise is the most important variable in intubation and that novice students will be unable to intubate if the angle of curvature is incorrect.MethodsAn observational cross-sectional study was planned with 30 anesthesia residents, categorized into three groups based on their expertise in laryngoscopy. Students had to intubate an airway mannequin using the C-MAC D-Blade (R) VL with three different stylet angulations. The curvatures were 80, 100, and 120 degrees, which are commonly encountered in routine day-to-day practice. The time to get a stable glottic view, time to intubate, and ease of intubation were measured.ResultsThe mean time to intubate was the least with 100-degree angulation in group C (19.60 +/- 0.97) while the maximum time was in group A with 80-degree angulation (61.49 +/- 3.69). A significant difference was noted in time to get a stable glottic view when compared between the groups. There was no difference in time to intubate with different stylet angulations when compared between groups.ConclusionsNovices and experts could intubate even if the angle of curvature was incorrect taking more time. The time to laryngoscopy is significantly dependent on experience, but the time to intubate is influenced by the angle of curvature of the stylet.
引用
收藏
页数:6
相关论文
共 15 条
  • [1] Impact of Videolaryngoscopy Expertise on First-Attempt Intubation Success in Critically Ill Patients
    Amalric, Matthieu
    Larcher, Romaric
    Brunot, Vincent
    Garnier, Fanny
    De Jong, Audrey
    Moulaire Rigollet, Valerie
    Corne, Philippe
    Klouche, Kada
    Jung, Boris
    [J]. CRITICAL CARE MEDICINE, 2020, 48 (10) : E889 - E896
  • [2] Role of video-based learning on competency level of direct laryngoscopic skills of novice anaesthesiologists - A randomised clinical trial
    Bakshi, Sumitra G.
    Singh, Pankaj
    Bhosale, Shil
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (10) : 712 - 718
  • [3] McGrath MAC video laryngoscope versus direct laryngoscopy for the placement of double-lumen tubes: A randomised control trial
    Bakshi, Sumitra G.
    Gawri, Ajay
    Divatia, Jigeeshu, V
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (06) : 456 - 461
  • [4] Defining the learning curve for endotracheal intubation using direct laryngoscopy: A systematic review
    Buis, Maria L.
    Maissan, Iscander M.
    Hoeks, Sanne E.
    Klimek, Markus
    Stolker, Robert J.
    [J]. RESUSCITATION, 2016, 99 : 63 - 71
  • [5] Improvement in glottic visualisation by using the C-MAC PM video laryngoscope as a first-line device for out-of-hospital emergency tracheal intubation An observational study
    Hossfeld, Bjoern
    Frey, Kristina
    Doerges, Volker
    Lampl, Lorenz
    Helm, Matthias
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (06) : 425 - 431
  • [6] Jain D, 2014, REV BRAS ANESTESIOL, V64, P269, DOI [10.1016/j.bjane.2013.06.005, 10.1016/j.bjan.2013.06.006]
  • [7] Seeing is believing: getting the best out of videolaryngoscopy
    Kelly, F. E.
    Cook, T. M.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 : 9 - +
  • [8] Comparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways
    Kilicaslan, Alper
    Topal, Ahmet
    Erol, Atilla
    Uzun, Sema Tuncer
    [J]. TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2014, 42 (04) : 182 - 189
  • [9] Comparing the McGrath Mac Video Laryngoscope and Direct Laryngoscopy for Prehospital Emergency Intubation in Air Rescue Patients: A Multicenter, Randomized, Controlled Trial*
    Kreutziger, Janett
    Hornung, Sonja
    Harrer, Clemens
    Urschl, Wilhelm
    Doppler, Reinhard
    Voelckel, Wolfgang G.
    Trimmel, Helmut
    [J]. CRITICAL CARE MEDICINE, 2019, 47 (10) : 1362 - 1370
  • [10] Videolaryngoscopy and Direct Laryngoscopy Equal for Air Medical Intubation? The Operator Matters
    Long, Micah T.
    Kory, Pierre D.
    Steuerwald, Michael T.
    Joffe, Aaron M.
    Galgon, Richard E.
    [J]. CRITICAL CARE MEDICINE, 2020, 48 (03) : E254 - E255