Smartphone-Based Quantitative Detection of Ochratoxin A in Wheat via a Lateral Flow Assay

被引:8
作者
Tian, Yunxin [1 ]
Hu, Xiaofeng [2 ,3 ]
Jiang, Jun [3 ]
Tang, Xiaoqian [3 ]
Tian, Zhiquan [1 ,4 ]
Zhang, Zhaowei [2 ,3 ]
Li, Peiwu [2 ,3 ]
机构
[1] Tibet Univ, Coll Ecol & Environm Sci, Lhasa 850000, Peoples R China
[2] Hubei Hongshan Lab, Wuhan 430070, Peoples R China
[3] Chinese Acad Agr Sci, Oil Crops Res Inst, Natl Reference Lab Agr Testing Biotoxin, Key Lab Detect Mycotoxins,Minist Agr & Rural Affai, Wuhan 430062, Peoples R China
[4] Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Ochratoxin A; smartphone; Europium nanospheres; fluorescent lateral flow test strip; wheat; quantitative detection; MYCOTOXINS; DEVICE;
D O I
10.3390/foods12030431
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Ochratoxin A (OTA) poses a severe health risk to livestock along the food chain. Moreover, according to the International Agency for Research on Cancer, it is also categorized as being possibly carcinogenic to humans. The lack of intelligent point-of-care test (POCT) methods restricts its early detection and prevention. This work establishes a smartphone-enabled point-of-care test for OTA detection via a fluorescent lateral flow assay within 6 min. By using a smartphone and portable reader, the assay allows for the recording and sharing of the detection results in a cloud database. This intelligent POCT provided (iPOCT) a linearity range of 0.1-3.0 ng/mL and a limit of detection (LOD) of 0.02 ng/mL (0.32 mu g/kg in wheat). By spiking OTA in blank wheat samples, the recoveries were 89.1-120.4%, with a relative standard deviation (RSD) between 3.9-9.1%. The repeatability and reproducibility were 94.2-101.7% and 94.6-103.4%, respectively. This work provides a promising intelligent POCT method for food safety.
引用
收藏
页数:10
相关论文
共 50 条
[21]   Smartphone detection of antibiotic resistance using convective PCR and a lateral flow assay [J].
Rajendran, Vinoth Kumar ;
Bakthavathsalam, Padmavathy ;
Bergquist, Peter L. ;
Sunna, Anwar .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 298
[22]   Smartphone-based competitive immunoassay for quantitative on-site detection of meat adulteration [J].
Seddaoui, Narjiss ;
Amine, Aziz .
TALANTA, 2021, 230 (230)
[23]   Smartphone-based fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of Zika virus nonstructural protein 1 [J].
Rong, Zhen ;
Wang, Qiong ;
Sun, Nanxi ;
Jia, Xiaofei ;
Wang, Keli ;
Xiao, Rui ;
Wang, Shengqi .
ANALYTICA CHIMICA ACTA, 2019, 1055 :140-147
[24]   Research Progress on Rapid Detection Technology Based on Smartphone and Lateral Flow Immunoassay [J].
Hui, Li ;
Ying, Ying ;
Zhen, Cao ;
Guang-Yang, Liu ;
Jing, Wang .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (01) :1-11
[25]   A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples [J].
Zhang, Guilan ;
Zhu, Chao ;
Huang, Yafei ;
Yan, Jiao ;
Chen, Ailiang .
MOLECULES, 2018, 23 (02)
[26]   Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection [J].
Carrio, Adrian ;
Sampedro, Carlos ;
Luis Sanchez-Lopez, Jose ;
Pimienta, Miguel ;
Campoy, Pascual .
SENSORS, 2015, 15 (11) :29569-29593
[27]   Detection of ochratoxin A by quantum dots-based fluorescent immunochromatographic assay [J].
Zhou, Jingming ;
Yang, Qingbao ;
Liang, Chao ;
Chen, Yumei ;
Zhang, Xiaoli ;
Liu, Zhanxiang ;
Wang, Aiping .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (01) :183-192
[28]   A smartphone-based quantitative detection device integrated with latex microsphere immunochromatography for on-site detection of zearalenone in cereals and feed [J].
Li, Xiangmei ;
Wang, Jin ;
Yi, Changqing ;
Jiang, Lelun ;
Wu, Jinxiao ;
Chen, Xiaomin ;
Shen, Xing ;
Sun, Yuanming ;
Lei, Hongtao .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 290 :170-179
[29]   Immunochromatographic Assay for Quantitative Detection of Ochratoxin A in Maize by Quantum Dot Beads [J].
Zhou Yao-Feng ;
Xiong Si-Cheng ;
Jiang Hu ;
Duan Hong ;
Xiong Yong-Hua ;
Wang, Andrew .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (12) :1837-1843
[30]   Barcode-style lateral flow immunochromatographic strip for the semi-quantitative detection of ochratoxin A in coffee samples [J].
Alvarez, Luis Alberto Contreras ;
Jara, Marcia Daniela Lazo ;
Campos, Fabiana Vasconcelos ;
de Oliveira, Jairo Pinto ;
Guimaraes, Marco Cesar Cunegundes .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2024, 41 (04) :424-437