Real-time surface temperature measurement of steel continuous casting strand in the steam-filled spray chamber

被引:2
|
作者
Huang, Yunwei [1 ]
Pan, Yitong [3 ]
Li, Chuan [1 ]
Long, Mujun [2 ]
Chen, Dengfu [2 ]
Yang, Zhe [1 ]
Long, Jianyu [1 ]
机构
[1] Dongguan Univ Technol, Sch Mech Engn, Dongguan 523808, Peoples R China
[2] Chongqing Univ, Coll Mat Sci & Engn, Lab Met & Mat, Chongqing 400044, Peoples R China
[3] Shenzhen Univ, Dept Educ Technol, Shenzhen 518060, Peoples R China
关键词
Strand surface temperature measurement; Steam -filled spray chamber; Water spray; Radiation thermometry; Steel continuous casting; HEAT-TRANSFER; SYSTEM; FEATURES; MODEL;
D O I
10.1016/j.ijthermalsci.2024.108909
中图分类号
O414.1 [热力学];
学科分类号
摘要
Accurate measuring strand surface temperature inside the steam-filled spray chamber in steel continuous casting process is important to realize closed-loop control of secondary cooling water and minimize surface cracks. However, the accuracy of radiation temperature measurement is greatly affected by the harsh environment in the steam-filled spray chamber, such as highly concentrated water vapor, water spray, intermittent water film and oxide scale layers on the surface. In this paper, a real-time temperature measurement system was specifically designed for detailed, accurate and reliable monitoring the strand surface temperature in the steam-filled spray chamber and had been implemented on commercial casters. In this system, a linear extrapolation method was applied to correct the effect of highly concentrated water vapor. The optimal combination of air flowrate and distance of sighting tube away from strand surface was chosen to simultaneously achieve the purposes of completely purging water spray and avoiding the overcooling of strand surface. A peak-picking method was employed to mitigate the effects of discontinuous water film and oxide scale layers. Comparison of the measured temperatures with temperature predictions using continuous casting simulation models illustrated the high accuracy of temperature measurements using this system. The test results in steel factories demonstrated the proposed temperature measurement system could meet the requirement of strand surface temperature measurements. Reliability and accuracy of measurement results were discussed.
引用
收藏
页数:11
相关论文
共 32 条
  • [11] A new semi-analytical model for prediction of the strand surface temperature in the continuous casting of steel in the mold region
    Alizadeh, Mostafa
    Jahromi, Ahmad Jenabali
    Abouali, Omid
    ISIJ INTERNATIONAL, 2008, 48 (02) : 161 - 169
  • [12] Surface Temperature Measurement of In-Vessel Components and Its Real-Time Validation
    Herrmann, A.
    Sieglin, B.
    Faitsch, M.
    FUSION SCIENCE AND TECHNOLOGY, 2016, 69 (03) : 569 - 579
  • [13] Stabilized holographic setup for the real-time continuous measurement of surface vibrational mode patterns
    Frejlich, J
    deCarvalho, E
    Freschi, AA
    Andreeta, JP
    Hernandes, AC
    Carvalho, JF
    Gallo, NJH
    SECOND INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 1996, 2868 : 205 - 215
  • [14] Real-Time Thermal Tracking Model With Consideration of Dynamic Thermophysical Properties Loading in the Process of Steel Continuous Casting
    Xing Xia
    Cheng Ji
    Miaoyong Zhu
    Metallurgical and Materials Transactions B, 2023, 54 : 3130 - 3142
  • [15] Real-Time Thermal Tracking Model With Consideration of Dynamic Thermophysical Properties Loading in the Process of Steel Continuous Casting
    Xia, Xing
    Ji, Cheng
    Zhu, Miaoyong
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2023, 54 (06): : 3130 - 3142
  • [16] Real-Time Temperature Prediction Model for Online Continuous Casting Control Using Simplified Boundary Condition Computing Method
    Guo, Shengrong
    Sharif, Johan Mohamad
    PROCESSES, 2025, 13 (02)
  • [17] Real-time measurement of wall surface temperature subject to hot impinging gas flow in combustion
    Furukawa, T
    Kuo, CH
    Yang, WJ
    KAGAKU KOGAKU RONBUNSHU, 2000, 26 (02) : 169 - 173
  • [18] Real-time measurement of birefringence, weight, thickness, and surface temperature during drying of novel materials for capacitors
    Marszalek, Jolanta E.
    Offenbach, Ido
    Unsal, Emre
    Baldwin, Aaron
    Ma, Rui
    Sotzing, Gregory A.
    Cakmak, Mukerrem
    Weiss, Robert
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 246
  • [19] Real-time laser-based measurement of interface temperature during droplet impingement on a cold surface
    Chen, Q
    Li, Y
    Longtin, JP
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (05) : 879 - 888
  • [20] High-resolution, real-time simultaneous 3D surface geometry and temperature measurement
    An, Yatong
    Zhang, Song
    OPTICS EXPRESS, 2016, 24 (13): : 14552 - 14563