Outcomes of the Pin and Plate Technique in Complex Fractures and Nonunions of Distal Humerus

被引:1
|
作者
Komijani, Mehdi [1 ]
Shamabadi, Ahmad [1 ,2 ]
Zanjani, Leila Oryadi [1 ,3 ]
Nabian, Mohammad Hossein [1 ,3 ]
Panjavi, Behnam [1 ]
Kamrani, Reza Shahriar [1 ,4 ]
机构
[1] Univ Tehran Med Sci, Shariati Hosp, Dept Orthoped, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Med, Tehran, Iran
[3] Univ Tehran Med Sci, Ctr Orthoped Transdisciplinary Appl Res COTAR, Sch Med, Tehran, Iran
[4] Univ Tehran Med Sci, Shariati Hosp, Dept Orthoped & Trauma Surg, North Kargar St, Tehran, Iran
来源
ARCHIVES OF BONE AND JOINT SURGERY-ABJS | 2023年 / 11卷 / 08期
关键词
Fracture fixation; Humeral fractures; Humerus; Humerus nonunion; Orthopedic fixation devices; INTERNAL-FIXATION; OPEN REDUCTION; SURGICAL-TREATMENT; ULNAR NERVE;
D O I
10.22038/ABJS.2023.69446.3268
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study investigates outcomes and complications of the pin and plate fixation technique, which was suggested for distal humerus fractures. It also reports the results of its application in nonunions for the first time.Methods: Forty-nine fracture and 17 nonunion cases who underwent surgery using the technique and were followed for at least 18 months were assessed through the range of motion (ROM), Quick Disabilities of the Arm, Shoulder, and Hand Score (Quick-DASH), Mayo Elbow Performance Score (MEPS), four-category verbal rating scale (VRS-4), and complications.Results: At the last follow-up, the mean scores of flexion, extension deficit, supination, and pronation ranges in fracture cases were 116.7, 22.9, 90.0, and 90.0 degrees, respectively. These values in nonunion cases were 112.2, 26.4, 86.7, and 85.5 degrees, respectively. The average ROM in fracture cases was 93.8, while it was 85.8 degrees in nonunion cases. The mean Quick-DASH in fracture and nonunion patients were 25.2 and 31.1, respectively. According to the MEPS, 77.5% of fracture and 64.7% of nonunion patients had excellent and good results. In fracture cases, the mean scores of VRS-4 at rest, light activity, and hard activity were 1.3, 1.8, and 2.3, respectively. These values in nonunion cases were 1.8, 2.2, and 2.5, respectively. The most common complications were device prominence and ulnar neuropathy.Conclusion: An acceptable union rate and proper elbow function can be expected by using this technique. Owing to the promising results of this study, further high-quality studies are recommended. Hereby this technique is called Persian Fixation.
引用
收藏
页码:503 / 509
页数:7
相关论文
共 50 条
  • [21] Distal Humerus Fractures Evolution of Management
    Stevens, Nicole M.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2021, 79 (01): : 43 - 50
  • [22] Posterolateral Locked Plate and Percutaneous Medial Screw Fixation for Distal Humerus Fractures in Elderly
    Kuwahara, Yutaro
    Hara, Tatsuya
    Kurahashi, Toshikazu
    Tatebe, Masahiro
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2024, 29 (04) : 321 - 327
  • [23] Stabilisation of articular fractures of the distal humerus: Early experience with a novel perpendicular plate system
    Reising, K.
    Hauschild, O.
    Strohm, P. C.
    Suedkamp, N. P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (06): : 611 - 617
  • [24] Anatomical plate configuration affects mechanical performance in distal humerus fractures
    Penzkofer, Rainer
    Hungerer, Sven
    Wipf, Felix
    von Oldenburg, Geert
    Augat, Peter
    CLINICAL BIOMECHANICS, 2010, 25 (10) : 972 - 978
  • [25] A biomechanical comparison of plate configuration in distal humerus fractures
    Arnander, Magnus W. T.
    Reeves, Alexander
    MacLeod, Iain A. R.
    Pinto, Thomas M.
    Khaleel, Arshad
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) : 332 - 336
  • [26] Distal humerus fractures nonunion with elbow stiffness in working adults: Can triple tension band technique and Lambda Plate® be a standby solution?
    Ayoub, Mostafa A.
    Khalil, Ayman E.
    Seleem, Osama A.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (02) : 147 - 153
  • [27] Management of distal humerus fractures
    Lauder, Alexander
    Richard, Marc J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (05) : 745 - 762
  • [28] Elbow Fractures: Distal Humerus
    Wong, Andrew S.
    Baratz, Mark E.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (01): : 176 - 190
  • [29] Fractures of the distal humerus operated on using the Lambda® plate: Report of 75 cases at 9.5 years follow-up
    Saragaglia, D.
    Rouchy, R. -C.
    Mercier, N.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (06) : 707 - 712
  • [30] Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate
    Capo, John T.
    Debkowska, Monika P.
    Liporace, Frank
    Beutel, Bryan G.
    Melamed, Eitan
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (05) : 1037 - 1043