Outcomes of the Pin and Plate Technique in Complex Fractures and Nonunions of Distal Humerus

被引:1
|
作者
Komijani, Mehdi [1 ]
Shamabadi, Ahmad [1 ,2 ]
Zanjani, Leila Oryadi [1 ,3 ]
Nabian, Mohammad Hossein [1 ,3 ]
Panjavi, Behnam [1 ]
Kamrani, Reza Shahriar [1 ,4 ]
机构
[1] Univ Tehran Med Sci, Shariati Hosp, Dept Orthoped, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Med, Tehran, Iran
[3] Univ Tehran Med Sci, Ctr Orthoped Transdisciplinary Appl Res COTAR, Sch Med, Tehran, Iran
[4] Univ Tehran Med Sci, Shariati Hosp, Dept Orthoped & Trauma Surg, North Kargar St, Tehran, Iran
来源
ARCHIVES OF BONE AND JOINT SURGERY-ABJS | 2023年 / 11卷 / 08期
关键词
Fracture fixation; Humeral fractures; Humerus; Humerus nonunion; Orthopedic fixation devices; INTERNAL-FIXATION; OPEN REDUCTION; SURGICAL-TREATMENT; ULNAR NERVE;
D O I
10.22038/ABJS.2023.69446.3268
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study investigates outcomes and complications of the pin and plate fixation technique, which was suggested for distal humerus fractures. It also reports the results of its application in nonunions for the first time.Methods: Forty-nine fracture and 17 nonunion cases who underwent surgery using the technique and were followed for at least 18 months were assessed through the range of motion (ROM), Quick Disabilities of the Arm, Shoulder, and Hand Score (Quick-DASH), Mayo Elbow Performance Score (MEPS), four-category verbal rating scale (VRS-4), and complications.Results: At the last follow-up, the mean scores of flexion, extension deficit, supination, and pronation ranges in fracture cases were 116.7, 22.9, 90.0, and 90.0 degrees, respectively. These values in nonunion cases were 112.2, 26.4, 86.7, and 85.5 degrees, respectively. The average ROM in fracture cases was 93.8, while it was 85.8 degrees in nonunion cases. The mean Quick-DASH in fracture and nonunion patients were 25.2 and 31.1, respectively. According to the MEPS, 77.5% of fracture and 64.7% of nonunion patients had excellent and good results. In fracture cases, the mean scores of VRS-4 at rest, light activity, and hard activity were 1.3, 1.8, and 2.3, respectively. These values in nonunion cases were 1.8, 2.2, and 2.5, respectively. The most common complications were device prominence and ulnar neuropathy.Conclusion: An acceptable union rate and proper elbow function can be expected by using this technique. Owing to the promising results of this study, further high-quality studies are recommended. Hereby this technique is called Persian Fixation.
引用
收藏
页码:503 / 509
页数:7
相关论文
共 50 条
  • [1] Pin and plate fixation in complex distal humerus fractures: surgical technique and results
    Kamrani, Reza Shariar
    Mehrpour, Saeed Reza
    Aghamirsalim, Mohamad Reza
    Sorbi, Reza
    Bashi, Ramin Zargar
    Kaya, Alper
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (04) : 839 - 844
  • [2] Functional results of the parallel-plate technique or complex distal humerus fractures
    Atalar, Ata Can
    Demirhan, Mehmet
    Salduz, Ahmet
    Kilicoglu, Oender
    Seyahi, Aksel
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (01) : 21 - 27
  • [3] Double tension band osteosynthesis in transverse supracondylar distal humerus fractures and nonunions
    Allende, Christian
    Gutierrez, Natalia
    Savoy, Ignacio Fernandez
    Allende, Bartolome T.
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (12) : 2565 - 2569
  • [4] Temporary spanning plate across the elbow for complex fractures of the distal humerus
    Moharram, Ashraf N.
    Mahmoud, Mostafa
    Lymona, Ahmed
    Afifi, Ahmed
    Ezzat, Mostafa
    Abdel-Wahed, Mohamed
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [5] Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus
    Spitzer, Allison B.
    Davidovitch, Roy I.
    Egol, Kenneth A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (03): : 240 - 244
  • [6] Treatment of Distal Humerus Articular Fracture with Pin-and-Plate Technique
    Abdoli, Abbas
    Farhoud, Amir Reza
    Kamrani, Reza Shahryar
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (03): : 332 - 339
  • [7] Anti-sliding plate technique for coronal shear fractures of the distal humerus
    Song, Zhe
    Wang, Qian
    Ma, Teng
    Wang, Chen
    Yang, Na
    Xue, Hanzhong
    Li, Zhong
    Zhu, Yangjun
    Zhang, Kun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [8] Functional outcomes of locking plate fixation in complex proximal humerus fractures
    Shaikh, Saeed Ahmed
    Arain, Muhammad Arif
    Rehman, Muhammad Mansoor
    Ahmed, Nadeem
    Samejo, Muhammad Qasim Ali
    RAWAL MEDICAL JOURNAL, 2020, 45 (03): : 633 - 636
  • [9] Precontoured Parallel Plate Fixation of AO/OTA Type C Distal Humerus Fractures
    Athwal, George S.
    Hoxie, Samuel C.
    Rispoli, Damian M.
    Steinmann, Scott P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (08) : 575 - 580
  • [10] Treatment of supra- and intra-articular fractures of the distal humerus with the LCP Distal Humerus Plate: a 2-year follow-up
    Kaiser, Timm
    Brunner, Alexander
    Hohendorff, Bernd
    Ulmar, Benjamin
    Babst, Reto
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (02) : 206 - 212