A time-resolved fluorescent microsphere-lateral flow immunoassay strip assay with image visual analysis for quantitative detection of Helicobacter pylori in saliva

被引:12
|
作者
Wang, Yilu [1 ]
Chen, Qiming [1 ]
Wang, Yingying [1 ]
Tu, Fangmin [1 ]
Chen, Xiaodi [1 ]
Li, Junhai [2 ,3 ]
Liu, Zhanmin [1 ,4 ]
机构
[1] Shanghai Univ, Sch Life Sci, Shanghai 200444, Peoples R China
[2] 215 Hosp Shaanxi Nucl Ind, Dept Oncol, Xianyang City 712000, Shaanxi Provinc, Peoples R China
[3] 215 Hosp Shaanxi Nucl Ind, Dept Oncol, 35 West Weiyang Rd, Xianyang City 712000, Shaanxi Provinc, Peoples R China
[4] Shanghai Univ, Sch Life Sci, 381 Nanchen Rd, Shanghai 200444, Peoples R China
关键词
Helicobacter pylori; Time-resolved fluorescent microsphere; Lateral flow immunoassay; Saliva; Self-test; GASTRIC BIOPSIES; ORAL SAMPLES; PCR; IDENTIFICATION; ERADICATION; INFECTION; DIAGNOSIS; DISEASE;
D O I
10.1016/j.talanta.2023.124317
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Helicobacter pylori (H. pylori) is a kind of microaerobic and food-borne pathogen. More than 4.4 billion in-dividuals have been infected by H. pylori and H. pylori was listed as Group I carcinogen by WHO in 1994. Considering the high infection rate of H. pylori and the limited medical resources, self-testing is helpful for diagnosis and timely treatment. Although the amount of H. pylori in human saliva is low, the sampling of saliva is simple and convenient compared with stomach, blood and stool samples. Therefore, H. pylori in human saliva can be an indicator for self-testing, and a sensitive and easy-to-use assay is necessary. In this study, we developed a time-resolved fluorescent microsphere-lateral flow immunoassay (TRFM-LFIA) strip assay with image visual analysis for detection of H. pylori in saliva. The detection of the TRFM-LFIA strip was easy to use and had a low dependency on equipment. With optimized preparation and detection parameters, the whole detection process could be finished in 8 min and the LOD by naked eyes was 102 CFU/mL. For quantitative analysis by image visual analysis, the LOD was as low as 1.05 CFU/mL in the linear range of 101-105 CFU/mL. Besides, the TRFM-LFIA strip also had good stability, reliability, repeatability and accuracy. All these advantages indicated that the TRFM-LFIA strips developed in this study had a good potential for self-testing for H. pylori infection.
引用
收藏
页数:9
相关论文
共 11 条
  • [1] A monoclonal antibody-based time-resolved fluorescence microsphere lateral flow immunoassay for paclobutrazol detection
    Cheng, Yongjian
    Xie, Bo
    Liang, Yifan
    Liu, Xinmei
    Chen, Haojie
    Li, Jiadong
    Lei, Hongtao
    Xiao, Zhili
    CURRENT RESEARCH IN FOOD SCIENCE, 2022, 5 : 1395 - 1402
  • [2] A time-resolved fluorescence lateral flow immunoassay for rapid and quantitative serodiagnosis of Brucella infection in humans
    Lu, Jinhui
    Wu, Ze
    Liu, Bochao
    Wang, Cong
    Wang, Qi
    Zhang, Ling
    Wang, Zhen
    Chen, Chuangfu
    Fu, Yongshui
    Li, Chengyao
    Li, Tingting
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 200
  • [3] Highly sensitive time-resolved fluorescent microspheres lateral flow immunoassay for the quantitative detection of triadimefon and its metabolite residues in fruits and vegetables
    Shi, San-Jun
    Ji, Mei-Qi
    Huang, Rong-Fu
    Fan, Zi-Yan
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [4] A visual denaturation bubble-mediated strand exchange amplification and RGB visual analysis-based assay for quantitative detection of Helicobacter pylori in saliva
    Yingying Wang
    Qiming Chen
    Yilu Wang
    Xiaodi Chen
    Fangmin Tu
    Junhai Li
    Zhanmin Liu
    Analytical Sciences, 2023, 39 : 483 - 491
  • [5] Development and evaluation of a time-resolved fluorescence labelled immunochromatographic strip assay for rapid and quantitative detection of bovine herpesvirus 1
    Liu, Wenxiao
    Zhang, Kun
    Cheng, Jing
    Yu, Shiqiang
    Cheng, Chunjie
    Jiang, Bo
    Zhou, Linyi
    Li, Yongqing
    FRONTIERS IN MICROBIOLOGY, 2024, 15
  • [6] A visual denaturation bubble-mediated strand exchange amplification and RGB visual analysis-based assay for quantitative detection of Helicobacter pylori in saliva
    Wang, Yingying
    Chen, Qiming
    Wang, Yilu
    Chen, Xiaodi
    Tu, Fangmin
    Li, Junhai
    Liu, Zhanmin
    ANALYTICAL SCIENCES, 2023, 39 (04) : 483 - 491
  • [7] Lateral Flow Immunoassay Based on Time-Resolved Fluorescence Microspheres for Rapid and Quantitative Screening CA199 in Human Serum
    Jiao, Xueshima
    Peng, Tao
    Liang, Zhanwei
    Hu, Yalin
    Meng, Bo
    Zhao, Yang
    Xie, Jie
    Gong, Xiaoyun
    Jiang, You
    Fang, Xiang
    Yu, Xiaoping
    Dai, Xinhua
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (17)
  • [8] Rapid and sensitive detection of interleukin-6 in serum via time-resolved lateral flow immunoassay
    Huang, Dezhi
    Ying, Haojun
    Jiang, Dongneng
    Liu, Fei
    Tian, Ye
    Du, Chunlan
    Zhang, Liqun
    Pu, Xiaoyun
    ANALYTICAL BIOCHEMISTRY, 2020, 588
  • [9] Development and evaluation of time-resolved fluorescent immunochromatographic assay for quantitative detection of SARS-CoV-2 spike antigen
    Xu, Buzhou
    Tang, Hao
    Weng, Yiming
    Jones, Valerie Sloane
    Luo, Shuhong
    Cho, Chih Yun
    Lin, Yongping
    Fang, Jianmin
    Song, Xuedong
    Huang, Ruo-Pan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (07)
  • [10] A highly sensitive and quantitative time resolved fluorescent microspheres lateral flow immunoassay for streptomycin and dihydrostreptomycin in milk, honey, muscle, liver, and kidney
    Jiang, Jiali
    Luo, Pengjie
    Liang, Jinxuan
    Shen, Xing
    Lei, Hongtao
    Li, Xiangmei
    ANALYTICA CHIMICA ACTA, 2022, 1192