FMB: Dual-view fusion and registration of 2D DSA images and 3D MRA images for neurointerventional-based procedures

被引:0
|
作者
Zhang, Chenyu [1 ]
Liu, Jiaxin [1 ]
Bian, Lisong [2 ]
Xiang, Sishi [3 ]
Liu, Jun [1 ]
Guan, Wenxue [4 ]
机构
[1] Beihang Univ, Coll Elect Informat Engn, Beijing 100191, Peoples R China
[2] Haidian Hosp, Neurosurg Dept, Beijing 100080, Peoples R China
[3] Capital Med Univ, Xuanwu Hosp, Neurosurg Dept, Beijing 100053, Peoples R China
[4] Jilin Univ, Coll Comp Sci & Technol, Changchun 130012, Peoples R China
基金
中国国家自然科学基金;
关键词
Rigid registration; 2D/3D registration; Pose estimation; Correspondence determination; Global rotation search; ANGIOGRAMS; ALGORITHMS;
D O I
10.1016/j.compbiomed.2024.107987
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: Alignment between preoperative images (high-resolution magnetic resonance imaging, magnetic resonance angiography) and intraoperative medical images (digital subtraction angiography) is currently required in neurointerventional surgery. Treating a lesion is usually guided by a 2D DSA silhouette image. DSA silhouette images increase procedure time and radiation exposure time due to the lack of anatomical information, but information from MRA images can be utilized to compensate for this in order to improve procedure efficiency. In this paper, we abstract this into the problem of relative pose and correspondence between a 3D point and its 2D projection. Multimodal images have a large amount of noise and anomalies that are difficult to resolve using conventional methods. According to our research, there are fewer multimodal fusion methods to perform the full procedure. Approach: Therefore, the paper introduces a registration pipeline for multimodal images with fused dual views is presented. Deep learning methods are introduced to accomplish feature extraction of multimodal images to automate the process. Besides, the paper proposes a registration method based on the Factor of Maximum Bounds (FMB). The key insights are to relax the constraints on the lower bound, enhance the constraints on the upper bounds, and mine more local consensus information in the point set using a second perspective to generate accurate pose estimation. Main results: Compared to existing 2D/3D point set registration methods, this method utilizes a different problem formulation, searches the rotation and translation space more efficiently, and improves registration speed. Significance: Experiments with synthesized and real data show that the proposed method was achieved in accuracy, robustness, and time efficiency.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] FMB: Dual-view fusion and registration of 2D DSA images and 3D MRA images for neurointerventional-based procedures
    Zhang, Chenyu
    Liu, Jiaxin
    Bian, Lisong
    Xiang, Sishi
    Liu, Jun
    Guan, Wenxue
    Computers in Biology and Medicine, 2024, 171
  • [2] Registration, matching, and data fusion in 2D/3D medical imaging: Application to DSA and MRA
    Vermandel, M
    Betrouni, N
    Palos, G
    Gauvrit, JY
    Vasseur, C
    Rousseau, J
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 778 - 785
  • [3] Vascular Structures Registration in 2D MRA Images
    Hermassi, Marwa
    Jelassi, Hejer
    Hamrouni, Kamel
    DIGITAL INFORMATION AND COMMUNICATION TECHNOLOGY AND ITS APPLICATIONS, PT I, 2011, 166 : 146 - +
  • [4] 2D/3D registration of neonatal brain images
    Vansteenkiste, Ewout
    Vandemeulebroucke, Jef
    Philips, Wilfried
    BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS, 2006, 4057 : 272 - 279
  • [5] Comparison of simultaneous and sequential two-view registration for 3D/2D registration of vascular images
    Pathak, C
    Van Horn, M
    Weeks, S
    Bullitt, E
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 239 - 246
  • [6] Model-based 3D/2D Deformable Registration of MR Images
    Marami, Bahram
    Sirouspour, Shahin
    Capson, David W.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4880 - 4883
  • [7] A method for registration and visualization of 3D MR images and 2D thermographic images for clinical application
    Gariba, MA
    Sanches, IJ
    Pardal, FC
    Bichinho, GL
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1280 - 1280
  • [8] Recovering 3D tumor locations from 2D bioluminescence images and registration with CT images
    Huang, Xiaolei
    Metaxas, Dimitris N.
    Menon, Lata G.
    Mayer-Kuckuk, Philipp
    Bertino, Joseph R.
    Banerjee, Debabrata
    MULTIMODAL BIOMEDICAL IMAGING, 2006, 6081
  • [9] Transfer Learning for Nonrigid 2D/3D Cardiovascular Images Registration
    Guan, Shaoya
    Wang, Tianmiao
    Sun, Kai
    Meng, Cai
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (09) : 3300 - 3309
  • [10] Evaluation of 3D-2D Registration Methods for Registration of 3D-DSA and 2D-DSA Cerebral Images
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669