Seismic Response Comparisons of Prefabricated and Cast In Situ Subway Station Structures in Liquefiable Site

被引:4
作者
An, Junhai [1 ]
Liu, Qiaofeng [1 ]
Zhang, Yanhua [1 ]
Zhang, Xuehui [1 ]
机构
[1] Hebei Univ Sci & Technol, Sch Civil Engn, Shijiazhuang 050018, Peoples R China
关键词
prefabricated subway station structure; liquefaction; seismic response; adaptability to deformation; numerical simulation;
D O I
10.3390/buildings13123071
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on the engineering practice of the first prefabricated subway station (Shuangfeng Station) in Changchun, China, the applicability of prefabricated subway station structures (PSSSs) in liquefiable sites in seismically defended areas is investigated. In this paper, the finite difference software FLAC3D 5.0 is used to carry out the seismic response analysis of the PSSS in liquefiable ground, and the calculation results of the PSSS are compared with those of the same type of cast-in-place subway station condition. The results show that the trend of foundation excess pore pressure ratio (EPPR) in the PSSS condition is similar to that of the cast-in-place condition. For different ground vibration inputs, there is not much difference between the PSSS and the cast-in-place structure on the pore pressure (PP) of the surrounding liquefiable soil. The acceleration response of the PSSS is slightly smaller than that of the cast-in-place structure, and it has a better ability to adapt to ground deformation. The deformation of the upper part of the PSSS is slightly larger than that of the lower part, which is an important part of its deformation control, and the middle part is the key part of its strength control due to the presence of the center plate, which results in a significant increase in stiffness and stress. The flexible connection of the PSSS is easier to adapt to a larger vertical deformation than rigid connection, and its ability to resist overturning is better. Under the premise of ensuring static waterproofing, the PSSS can be constructed in liquefiable sites in earthquake-proof areas.
引用
收藏
页数:15
相关论文
共 19 条
  • [1] An J., 2022, Sci. Technol. Eng, V22, P7080
  • [2] Quantification of seismic performance index limits and evaluation of seismic fragility for a new rectangular prefabricated subway station structure
    Chen, Jinnan
    Xu, Chengshun
    El Naggar, Hesham M.
    Du, Xiuli
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 138
  • [3] Physical and numerical modeling of seismic soil-structure interaction of prefabricated subway station structure
    Chen, Jinnan
    Xu, Chengshun
    Du, Xiuli
    Han, Runbo
    El Naggar, Hesham M.
    [J]. ENGINEERING STRUCTURES, 2023, 290
  • [4] [程科 Cheng Ke], 2020, [华中科技大学学报. 自然科学版, Journal of Huazhong University of Science and Technology. Nature Science], V48, P83
  • [5] Three-dimensional dynamic response analysis of a single-ring structure in a prefabricated subway station
    Ding, Peng
    Tao, Lianjin
    Yang, Xiuren
    Zhao, Ji
    Shi, Cheng
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2019, 45 : 271 - 286
  • [6] [杜修力 Du Xiuli], 2017, [土木工程学报, China Civil Engineering Journal], V50, P38
  • [7] Jiang Z.W., 2023, Eng. Mech, P1, DOI [10.6052/j.issn.1000-4750.2022.10.0904, DOI 10.6052/J.ISSN.1000-4750.2022.10.0904]
  • [8] Lingvay I, 2018, REV CHIM-BUCHAREST, V69, P3593
  • [9] Shaking Table Test on Influence of Liquefiable Soil Distribution on Seismic Response of Soil and Subway Underground Structures
    Liu C.
    [J]. Zhongguo Tiedao Kexue/China Railway Science, 2021, 42 (05): : 30 - 40
  • [10] The seismic behaviour of precast concrete interior joints with different connection methods in assembled monolithic subway station
    Liu, Hongtao
    Wang, Zhenyu
    Du, Xiuli
    Shen, Geoffrey Q. P.
    [J]. ENGINEERING STRUCTURES, 2021, 232