Study the corrosion issues on galvanized steel induced in water tanks

被引:5
作者
Gaber, Ghalia A. [1 ]
Mohamed, Lamiaa Z. [2 ]
Abdelfatah, Aliaa [2 ]
机构
[1] Al Azhar Univ, Fac Sci Girls, Dept Chem, Yousef Abbas Str,POB 11754, Nasr City, Cairo, Egypt
[2] Cairo Univ, Fac Engn, Min Petr & Met Engn Dept, Giza 12613, Egypt
关键词
Corrosion; Corrosion measurements; Galvanized steel; Environmental impact; Biocide hypochlorite; SODIUM-HYPOCHLORITE; BIOFILM CONTROL; CARBON-STEEL; BEHAVIOR; SEAWATER; BIOCIDE; ALLOY; LAYER; ZN;
D O I
10.1007/s11696-023-03043-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Weight loss, potentiodynamic polarization, and cyclic voltammetry tests were employed to assess the effects of sodium hypochlorite concentration and pH on the corrosion characteristics of galvanized steel in water tanks. Pitting corrosion appeared on the galvanized steel concurrently in neutral drinkable water. Passivation developed after exposure to 70 mg/L sodium hypochlorite solutions. The results demonstrated that adding NaClO to wastewater solutions reduced the corrosion rate. The corrosion rate of wastewater is 568.7 m/y, which can be reduced by adding NaClO to a lower value of 22.94 m/y at 70 mg/L. NaClO has the maximum efficiency at 70 mg/L, with a value of 95.96%. It was discovered that the galvanized steel in potable water was sensitive to passivation dissolution when hypochlorite solutions with concentrations ranging from 30 to 70 mg/L were added. However, hypochlorite solutions with concentrations greater than 150 mg/L cause significant corrosion on galvanized steel. The PDP and cyclic voltammetry findings revealed that the galvanized steel had good passivation properties under high 70 mg/L sodium hypochlorite concentrations. Only the sodium hypochlorite decreased the amounts of all sessile microorganism families. The scanning electron microscope was employed to check the corroded samples' morphology. Pitting corrosion was discovered alongside galvanic corrosion and uniform corrosion.Kindly check and confirm whether the corresponding author mail ID is correctly identified.Confirmed
引用
收藏
页码:7539 / 7549
页数:11
相关论文
共 34 条
[11]   A new approach to testing the efficacy of drinking water disinfectants [J].
Grunert, Andreas ;
Frohnert, Anne ;
Selinka, Hans-Christoph ;
Szewzyk, Regine .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2018, 221 (08) :1124-1132
[12]   Effect of additives and electrode roughness on the production of hypochlorite sanitizer by the electrolysis of NaCl solution in a batch recycle reactor [J].
Kamel, M. ;
El-Ashtoukhy, E. S. Z. ;
Abdel-Aziz, M. H. ;
Zahran, R. R. ;
Sedahmed, G. H. ;
El Gheriany, I. .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2022, 176
[13]   Incorporation of ceramic nanocontainers into epoxy coatings for the corrosion protection of hot dip galvanized steel [J].
Kartsonakis, I. A. ;
Balaskas, A. C. ;
Koumoulos, E. P. ;
Charitidis, C. A. ;
Kordas, G. .
CORROSION SCIENCE, 2012, 57 :30-41
[14]   Microbiologically Influenced Corrosion Mechanism of Ferrous Alloys in Marine Environment [J].
Khan, M. Saleem ;
Liang, Tao ;
Liu, Yuzhi ;
Shi, Yunzhu ;
Zhang, Huanhuan ;
Li, Hongyu ;
Guo, Shifeng ;
Pan, Haobo ;
Yang, Ke ;
Zhao, Ying .
METALS, 2022, 12 (09)
[15]   A novel cyclic voltammetric determination of free chlorine generated by ozone disinfection in seawater aquariums [J].
Ko, Kye Hak ;
Kim, Gang Hyok ;
Song, Jong Gu ;
Kim, Song Guk .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (04)
[16]  
LECHEVALLIER MW, 1993, J AM WATER WORKS ASS, V85, P111
[17]   Effects of pH and Cl- concentration on corrosion behavior of the galvanized steel in simulated rust layer solution [J].
Liu, Shuan ;
Sun, Huyuan ;
Sun, Lijuan ;
Fan, Huiji .
CORROSION SCIENCE, 2012, 65 :520-527
[18]   Iron pipe corrosion in distribution systems [J].
McNeill, LS ;
Edwards, M .
JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2001, 93 (07) :88-+
[19]   The corrosion behaviour of galvanized steel in cooling tower water containing a biocide and a corrosion inhibitor [J].
Minnos, Bihter ;
Ilhan-Sungur, Esra ;
Cotuk, Aysin ;
Gungor, Nihal Dogruoz ;
Cansever, Nurhan .
BIOFOULING, 2013, 29 (03) :223-235
[20]   Biofilm control for plate heat exchangers using surface seawater from the open ocean for the OTEC power plant [J].
Murthy, PS ;
Venkatesan, R ;
Nair, KVK ;
Ravindran, M .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2004, 53 (02) :133-140