In Situ Deposition of Gold Nanoparticles and L-Cysteine on Screen-Printed Carbon Electrode for Rapid Electrochemical Determination of As(III) in Water and Tea

被引:11
作者
Wang, Wenjing [1 ]
Yi, Zhijian [1 ]
Liang, Qiongxin [1 ]
Zhen, Junjie [2 ]
Wang, Rui [3 ]
Li, Mei [1 ]
Zeng, Lingwen [1 ,4 ]
Li, Yongfang [1 ]
机构
[1] Foshan Univ, Sch Food Sci & Engn, Foshan 528231, Peoples R China
[2] Guangdong Langyuan Biotechnol Co Ltd, Foshan 528313, Peoples R China
[3] Fudan Univ, Human Phenome Inst, State Key Lab Genet Engn, Shanghai 200438, Peoples R China
[4] Wuhan Zhongkezhikang Biotechnol Co Ltd, Wuhan 430223, Peoples R China
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 01期
基金
中国国家自然科学基金;
关键词
As(III); L-cysteine; in situ deposition; screen-printed carbon electrodes; linear sweep anodic stripping voltammetry;
D O I
10.3390/bios13010130
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a screen-printed carbon electrode (SPCE) based on in situ deposition modification was developed for the sensitive, rapid, easy and convenient determination of As(III) in water and tea by linear sweep anodic stripping voltammetry (LSASV). The screen-printed carbon electrodes were placed in a solution consisting of As(III) solution, chlorauric acid and L-cysteine. Under certain electrical potential, the chloroauric acid was reduced to gold nanoparticles (AuNPs) on the SPCE. L-cysteine was self-assembled onto AuNPs and promoted the enrichment of As(III), thus enhancing the determination specificity and sensitivity of As(III). The method achieved a limit of determination (LOD) of 0.91 ppb (mu g L-1), a linear range of 1 similar to 200 mu g L-1, an inter-assay coefficient of variation of 5.3% and good specificity. The developed method was successfully applied to the determination of As(III) in tap water and tea samples, with a recovery rate of 93.8%similar to 105.4%, and further validated by inductively coupled plasma mass spectrometry (ICP-MS). The developed method is rapid, convenient and accurate, holding great promise in the on-site determination of As(III) in tap water and tea leaves, and it can be extended to the detection of other samples.
引用
收藏
页数:12
相关论文
共 48 条
  • [41] Voltammetric determination of meloxicam in pharmaceutical formulation and human serum at glassy carbon electrode modified by cysteic acid formed by electrochemical oxidation of L-cysteine
    Wang, Cheng Yin
    Wang, Zhi Xian
    Guan, Jun
    Hu, Xiao Ya
    [J]. SENSORS, 2006, 6 (09) : 1139 - 1152
  • [42] A sensitive electrochemical sensor based on aluminium doped copper selenide nanoparticles-modified screen printed carbon electrode for determination of L-tyrosine in pharmaceutical samples
    Murtada, Khaled
    Salghi, Rachid
    Rios, Angel
    Zougagh, Mohammed
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 874
  • [43] Voltammetric behaviour of DNA bases at a screen-printed carbon electrode and its application to a simple and rapid voltammetric method for the determination of oxidative damage in double stranded DNA
    Honeychurch, Kevin C.
    O'Donovan, Michael R.
    Hart, John P.
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) : 2057 - 2064
  • [44] Highly selective and sensitive electrochemical sensor for L-cysteine detection based on graphene oxide/multiwalled carbon nanotube/manganese dioxide/gold nanoparticles composite
    Wang, Xiaojiao
    Luo, Chuannan
    Li, Leilei
    Duan, Huimin
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 757 : 100 - 106
  • [45] Simultaneous determination of L-cysteine and L-tyrosine using Au-nanoparticles/poly-eriochrome black T film modified glassy carbon electrode
    Liu, Xiao
    Luo, Liqiang
    Ding, Yaping
    Kang, Zhangping
    Ye, Daixin
    [J]. BIOELECTROCHEMISTRY, 2012, 86 : 38 - 45
  • [46] Differential pulse voltammetric determination of nimesulide in pharmaceutical formulation and human serum at glassy carbon electrode modified by cysteic acid/CNTs based on electrochemical oxidation of L-cysteine
    Wang, Chengyin
    Shao, Xiaoqiu
    Liu, Qingxiu
    Qu, Qishu
    Yang, Gongjun
    Hu, Xiaoya
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (02) : 237 - 244
  • [47] Simple, rapid and enzyme-free assay for potentiometric determination of L-cysteine based on meso-2,3-dimercaptosuccinic acid self-assembled gold electrode
    Wu, Yuan-Qing
    Xiao, Hong-Shu
    Peng, Yu-Yu
    Wu, Bo-Wen
    Li, Bin
    Ding, Yi-Chao
    Li, Dan
    Wu, Ling
    Yu, Donghong
    Cao, Zhong
    [J]. MICROCHEMICAL JOURNAL, 2024, 206
  • [48] Electrocatalytic simultaneous determination of ascorbic acid, uric acid and L-Cysteine in real samples using quercetin silver nanoparticles-graphene nanosheets modified glassy carbon electrode
    Zare, Hamid R.
    Jahangiri-Dehaghani, Fahime
    Shekari, Zahra
    Benvidi, Ali
    [J]. APPLIED SURFACE SCIENCE, 2016, 375 : 169 - 178