Correlation of Ocular Biometry with Axial Length in Elderly Japanese

被引:1
|
作者
Tanaka, Takahiro [1 ]
Nishitsuka, Koichi [1 ,2 ]
Obata, Hiroto [1 ]
机构
[1] Saitama Med Univ, Saitama Med Ctr, Dept Ophthalmol, Kawagoe, Saitama, Japan
[2] Saitama Med Univ, Saitama Med Ctr, Dept Otolaryngol, 1981 Kamoda, Kawagoe, Saitama, Japan
来源
CLINICAL OPHTHALMOLOGY | 2024年 / 18卷
关键词
preoperative cataract patients; central corneal thickness; average anterior corneal radius of curvature; white-to-white; anterior chamber depth; lens thickness; ANTERIOR-CHAMBER DEPTH; CENTRAL CORNEAL THICKNESS; CATARACT-SURGERY CANDIDATES; LENS THICKNESS; POPULATION; MYOPIA; DETERMINANTS; ASSOCIATIONS; ASTIGMATISM; PREVALENCE;
D O I
10.2147/OPTH.S446031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Ocular parameters are not only useful for diagnosing diseases but also for guiding treatment approaches. A lot of previous studies have reported ocular parameters and its relations before cataract surgery. However, despite ethnic differences in ocular biometry, few reports have dealt with Japanese. Hence, this retrospective cross-sectional study aimed to measure parameters of preoperative cataract patients and examines the correlations between each parameter in Japanese elderly people. Patients and Methods: The 210 subjects had their ocular axial lengths measured with OA-2000. The endpoints were ocular axial length (AL), central corneal thickness (CCT), average anterior corneal radius of curvature (CR), white-to-white (WTW), anterior chamber depth (ACD), and lens thickness (LT). Our analyses utilized the eye with the longer AL in each person. Each parameter was analyzed for correlations in a round -robin manner. Regression analyses were performed on parameters correlated with AL. Results: The parameters correlated with AL were CR (r = 0.33, P < 0.0001), WTW (r = 0.29, P < 0.0001), ACD (r = 0.59, P < 0.0001), and LT (r = -0.30, P < 0.0001). These parameters related to AL in all simple regression equations (CR (P < 0.0001), WTW (P = 0.0002), ACD (P < 0.0001), LT (P = 0.0001)). In multiple regression analyses, CR, ACD, and LT might relate to AL (CR (P = 0.0002), ACD (P < 0.0001), LT (P = 0.018)). LT tended to be thinner as AL increased, while CR, WTW, and ACD tended to increase. Conclusion: This information may be useful in developing strategies for ophthalmic surgery, as it provides information on the location of intraocular tissues. Various parameters have been used in intraocular lens (IOL) power calculations in recent years and knowledge of the interrelationship among parameters may be useful in determining IOL power according to ethnicity in the future.
引用
收藏
页码:351 / 360
页数:10
相关论文
共 50 条
  • [31] Correlation of Central Corneal Thickness and Axial Length in Myopes, Emmetropes, and Hypermetropes
    Solu, Trupti
    Baravaliya, Pathik
    Patel, Isha
    Kamble, Santosh
    Savaliya, Chetan
    Golakiya, Bhavesh
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 3 (12) : 202 - 205
  • [32] The Bigaussian Nature of Ocular Biometry
    Rozema, Jos J.
    Tassignon, Marie-Jose
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (07) : 713 - 722
  • [33] Evaluation of the agreement of optical biometry and Scheimpflug corneal topography with different axial lengths
    Gurlevik, U.
    Yasar, E.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (10): : 1576 - 1583
  • [34] Relationship between retinal artery trajectory and axial length in Japanese school students
    Yamashita, Takehiro
    Terasaki, Hiroto
    Yoshihara, Naoya
    Kii, Yuya
    Uchino, Eisuke
    Sakamoto, Taiji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (03) : 315 - 320
  • [35] Estimation of ocular axial length from conventional optometric measures
    Morgan, Philip B.
    McCullough, Sara J.
    Saunders, Kathryn J.
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (01) : 18 - 20
  • [36] Interocular Difference of Axial Length, Anterior Chamber Depth, Keratometry, Corneal Astigmatism According to Axial Length
    Lee, Moon Hyung
    Kim, Hong Kyu
    Kim, Sung Soo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (01): : 83 - 88
  • [37] Relationship of Ocular Biometry and Retinal Vascular Caliber in Preschoolers
    Li, Ling-Jun
    Cheung, Carol Yim-Lui
    Gazzard, Gus
    Chang, Lan
    Mitchell, Paul
    Wong, Tien-Yin
    Saw, Seang-Mei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (13) : 9561 - 9566
  • [38] Estimation of ocular volume from axial length
    Nagra, Manbir
    Gilmartin, Bernard
    Logan, Nicola S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (12) : 1697 - 1701
  • [39] Impact of Ethnicity on the Correlation of Retinal Parameters with Axial Length
    Tariq, Yasser M.
    Samarawickrama, Chameen
    Pai, Amy
    Burlutsky, George
    Mitchell, Paul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (10) : 4977 - 4982
  • [40] Axial length and anterior chamber indices in elderly population: Tehran Geriatric Eye Study
    Hashemi, Hassan
    Heydarian, Samira
    Hashemi, Alireza
    Khabazkhoob, Mehdi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2023, 16 (11) : 1876 - 1882