Relative biological effectiveness for epithermal neutron beam contaminated with fast neutrons in the linear accelerator-based boron neutron capture therapy system coupled to a solid-state lithium target

被引:6
|
作者
Nakamura, Satoshi [1 ,2 ,3 ]
Imamichi, Shoji [2 ,4 ,5 ]
Shimada, Kenzi [6 ]
Takemori, Mihiro [1 ,2 ,7 ]
Kanai, Yui [2 ,4 ,8 ]
Iijima, Kotaro [1 ]
Chiba, Takahito [1 ,7 ]
Nakayama, Hiroki [1 ,7 ]
Nakaichi, Tetsu [1 ,2 ]
Mikasa, Shohei [1 ]
Urago, Yuka [1 ,7 ]
Kashihara, Tairo [9 ]
Takahashi, Kana [9 ]
Nishio, Teiji [3 ]
Okamoto, Hiroyuki [1 ]
Itami, Jun [9 ]
Ishiai, Masamichi [4 ]
Suzuki, Minoru [10 ]
Igaki, Hiroshi [2 ,9 ,11 ]
Masutani, Mitsuko [2 ,4 ,5 ]
机构
[1] Natl Canc Ctr, Div Radiat Safety & Qual Assurance, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[2] Natl Canc Ctr, Exploratory Oncol Res & Clin Trial Ctr, Div Boron Neutron Capture Therapy, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[3] Osaka Univ, Grad Sch Med, Div Hlth Sci, Med Phys Lab, 1 7 Yamadaoka, Suita, Osaka 5650871, Japan
[4] Natl Canc Ctr, Cent Radioisotope Div, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[5] Nagasaki Univ, Dept Mol & Genom Biomed, Grad Sch Biomed Sci, 1 7 1 Sakamoto, Nagasaki 8528588, Japan
[6] Canc Intelligence Care Syst Inc, 3 5 7 Ariake,Koto ku, Tokyo 1350063, Japan
[7] Grad Sch Human Hlth Sci, Dept Radiol Sci, 7 2 10 Higashiogu,Arakawa ku, Tokyo 1168551, Japan
[8] Tokyo Inst Technol, Inst Innovat Res, Lab Zero Carbon Energy, 2 12 1 Ookayama,Meguro ku, Tokyo 1525880, Japan
[9] Natl Canc Ctr, Dept Radiat Oncol, 5 1 1 Tsukiji, Chuo ku, Tokyo 1040045, Japan
[10] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, 2 Asashiro Nishi, Kumatori cho, Osaka 5900494, Japan
[11] Tsukiji 5 1 1, Chuo ku, Tokyo 1040045, Japan
基金
日本学术振兴会;
关键词
neutron beam; solid-state Li target; relative biological effectiveness (RBE); accelerator-based BNCT system; boron neutron capture therapy (BNCT); RECURRENT HEAD; NECK-CANCER; B-10; BNCT; GLIOBLASTOMA; IRRADIATION; FACILITY; BRAIN;
D O I
10.1093/jrr/rrad037
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to quantify the relative biological effectiveness (RBE) for epithermal neutron beam contaminated with fast neutrons in the accelerator-based boron neutron capture therapy (BNCT) system coupled to a solid-state lithium target. The experiments were performed in National Cancer Center Hospital (NCCH), Tokyo, Japan. Neutron irradiation with the system provided by Cancer Intelligence Care Systems (CICS), Inc. was performed. X-ray irradiation, which was assigned as the reference group, was also performed using a medical linear accelerator (LINAC) equipped in NCCH. The four cell lines (SAS, SCCVII, U87-MG and NB1RGB) were utilized to quantify RBE value for the neutron beam. Before both of those irradiations, all cells were collected and dispensed into vials. The doses of 10% cell surviving fraction (SF) (D10) were calculated by LQ model fitting. All cell experiments were conducted in triplicate at least. Because the system provides not only neutrons, but gamma-rays, the contribution from the gamma-rays to the survival fraction were subtracted in this study. D10 value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was 4.26, 4.08, 5.81 and 2.72 Gy, respectively, while that acquired by the X-ray irradiation was 6.34, 7.21, 7.12 and 5.49 Gy, respectively. Comparison of both of the D10 values, RBE value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was calculated as 1.7, 2.2, 1.3 and 2.5, respectively, and the average RBE value was 1.9. This study investigated RBE of the epithermal neutron beam contaminated with fast neutrons in the accelerator-based BNCT system coupled to a solid-state lithium target.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 31 条
  • [11] Development of an online neutron beam monitoring system for accelerator-based boron neutron capture therapy in a hospital
    Takada, Masashi
    Yagi, Natsumi
    Nakamura, Satoshi
    Shimada, Kenzi
    Itami, Jyun
    Igaki, Hiroshi
    Nakamura, Masaru
    Nunomiya, Tomoya
    Endo, Satoru
    Kajimoto, Tsuyoshi
    Tanaka, Kenichi
    Aoyama, Kei
    Narita, Masakuni
    Nakamura, Takashi
    MEDICAL PHYSICS, 2024, : 605 - 618
  • [12] Long-term beam output stability of an accelerator-based boron neutron capture therapy system
    Komori, Shinya
    Takeuchi, Akihiko
    Kato, Ryohei
    Yamazaki, Yuhei
    Motoyanagi, Tomoaki
    Narita, Yuki
    Kato, Takahiro
    Takai, Yoshihiro
    MEDICAL PHYSICS, 2024, : 9250 - 9263
  • [13] Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study
    Cheon, Bo-Wi
    Yoo, Dohyeon
    Park, Hyojun
    Lee, Hyun Cheol
    Shin, Wook-Geun
    Choi, Hyun Joon
    Hong, Bong Hwan
    Chung, Heejun
    Min, Chul Hee
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (06) : 1970 - 1978
  • [14] Evaluation of radioactivity in the bodies of mice induced by neutron exposure from an epi-thermal neutron source of an accelerator-based boron neutron capture therapy system
    Nakamura, Satoshi
    Imamichi, Shoji
    Masumoto, Kazuyoshi
    Ito, Masashi
    Wakita, Akihisa
    Okamoto, Hiroyuki
    Nishioka, Shie
    Iijima, Kotaro
    Kobayashi, Kazuma
    Abe, Yoshihisa
    Igaki, Hiroshi
    Kurita, Kazuyoshi
    Nishio, Teiji
    Masutani, Mitsuko
    Itami, Jun
    PROCEEDINGS OF THE JAPAN ACADEMY SERIES B-PHYSICAL AND BIOLOGICAL SCIENCES, 2017, 93 (10): : 821 - 831
  • [15] Development of beryllium-based neutron target system with three-layer structure for accelerator-based neutron source for boron neutron capture therapy
    Kumada, Hiroaki
    Kurihara, Toshikazu
    Yoshioka, Masakazu
    Kobayashi, Hitoshi
    Matsumoto, Hiroshi
    Sugano, Tomei
    Sakurai, Hideyuki
    Sakae, Takeji
    Matsumura, Akira
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 78 - 83
  • [16] Scalp angiosarcoma treated with linear accelerator-based boron neutron capture therapy: A report of two patients
    Igaki, Hiroshi
    Murakami, Naoya
    Nakamura, Satoshi
    Yamazaki, Naoya
    Kashihara, Tairo
    Takahashi, Akira
    Namikawa, Kenjiro
    Takemori, Mihiro
    Okamoto, Hiroyuki
    Iijima, Kotaro
    Chiba, Takahito
    Nakayama, Hiroki
    Takahashi, Ayaka
    Kaneda, Tomoya
    Takahashi, Kana
    Inaba, Koji
    Okuma, Kae
    Nakayama, Yuko
    Shimada, Kazuaki
    Nakagama, Hitoshi
    Itami, Jun
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2022, 33 : 128 - 133
  • [17] Mixed-field dosimetry measurement of a target assembly for an accelerator-based neutron source for boron neutron capture therapy
    Reed, MK
    Dobelbower, MC
    Woollard, JE
    Blue, TE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (01) : 160 - 166
  • [18] Characterization of Be Deposits on Mo, W and Cu Substrates, to Implement in a Neutron Production Target for Accelerator-based Boron Neutron Capture Therapy
    Suarez Anzorena, M.
    Gagetti, L.
    del Grosso, M. F.
    Kreiner, A. J.
    INTERNATIONAL CONGRESS OF SCIENCE AND TECHNOLOGY OF METALLURGY AND MATERIALS, SAM - CONAMET 2013, 2015, 8 : 471 - 477
  • [19] Acral cutaneous malignant melanoma treated with linear accelerator-based boron neutron capture therapy system: a case report of first patient
    Igaki, Hiroshi
    Nakamura, Satoshi
    Yamazaki, Naoya
    Kaneda, Tomoya
    Takemori, Mihiro
    Kashihara, Tairo
    Murakami, Naoya
    Namikawa, Kenjiro
    Nakaichi, Tetsu
    Okamoto, Hiroyuki
    Iijima, Kotaro
    Chiba, Takahito
    Nakayama, Hiroki
    Nagao, Ayaka
    Sakuramachi, Madoka
    Takahashi, Kana
    Inaba, Koji
    Okuma, Kae
    Nakayama, Yuko
    Shimada, Kazuaki
    Nakagama, Hitoshi
    Itami, Jun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [20] Determining a methodology of dosimetric quality assurance for commercially available accelerator-based boron neutron capture therapy system
    Hirose, Katsumi
    Kato, Takahiro
    Harada, Takaomi
    Motoyanagi, Tomoaki
    Tanaka, Hiroki
    Takeuchi, Akihiko
    Kato, Ryohei
    Komori, Shinya
    Yamazaki, Yuhei
    Arai, Kazuhiro
    Kadoya, Noriyuki
    Sato, Mariko
    Takai, Yoshihiro
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (04) : 620 - 635