Impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion in patients with suspected stroke

被引:0
作者
Rau, Alexander [1 ,2 ]
Reisert, Marco [3 ,4 ]
Stein, Thomas [2 ]
Mueller-Peltzer, Katharina [2 ]
Rau, Stephan [2 ]
Bamberg, Fabian [2 ]
Taschner, Christian A. [1 ]
Urbach, Horst [1 ]
Kellner, Elias [3 ]
机构
[1] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Neurol & Clin Neurosci, Freiburg, Germany
[2] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Freiburg, Germany
[3] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Med Phys, Freiburg, Germany
[4] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Stereotact & Funct Neurosurg, Freiburg, Germany
关键词
Perfusion; Stroke; Radiation dosage; Computed tomography; ACUTE ISCHEMIC-STROKE; VOLUME; PARAMETERS; SOFTWARE; EXPOSURE;
D O I
10.1007/s00234-024-03335-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeCT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke.MethodsWe retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared.ResultsThe agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4.ConclusionReducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.
引用
收藏
页码:749 / 759
页数:11
相关论文
共 50 条
  • [41] 3D movement correction of CT brain perfusion image data of patients with acute ischemic stroke
    Fahmi Fahmi
    Henk A. Marquering
    Jordi Borst
    Geert J. Streekstra
    Ludo F. M. Beenen
    Joris M. Niesten
    Birgitta K. Velthuis
    Charles B. L. Majoie
    Ed vanBavel
    [J]. Neuroradiology, 2014, 56 : 445 - 452
  • [42] Reliability of Visual Assessment of Non-Contrast CT, CT Angiography Source Images and CT Perfusion in Patients with Suspected Ischemic Stroke
    van Seeters, Tom
    Biessels, Geert Jan
    Niesten, Joris M.
    van der Schaaf, Irene C.
    Dankbaar, Jan Willem
    Horsch, Alexander D.
    Mali, Willem P. T. M.
    Kappelle, L. Jaap
    van der Graaf, Yolanda
    Velthuis, Birgitta K.
    [J]. PLOS ONE, 2013, 8 (10):
  • [43] First-Pass CT Perfusion in Small Peripheral Lung Cancers: Effect of the Temporal Interval between Scan Acquisitions on the Radiation Dose and Quantitative Vascular Parameters
    Shan, Fei
    Xing, Wei
    Qiu, Jianguo
    Zhang, Zhiyong
    Yang, Shan
    [J]. ACADEMIC RADIOLOGY, 2013, 20 (08) : 972 - 979
  • [44] Validation of a novel CT perfusion software compared to RAPID in stroke patients receiving endovascular therapy
    Chen, Dan
    Chen, Wenhuo
    Nguyen, Thanh N.
    Yi, Tingyu
    Zhang, Luyun
    Guo, Xinze
    Chang, Yanting
    Bai, Xue
    Deng, Bowen
    Zhang, Yang
    Zhao, Yang
    Qiu, Tingting
    Wang, Yu
    Sui, Yi
    [J]. SCIENTIFIC REPORTS, 2025, 15 (01):
  • [45] Hepatic CT perfusion measurements: A feasibility study for radiation dose reduction using new image reconstruction method
    Negi, Noriyuki
    Yoshikawa, Takeshi
    Ohno, Yoshiharu
    Somiya, Yuichiro
    Sekitani, Toshinori
    Sugihara, Naoki
    Koyama, Hisanobu
    Kanda, Tomonori
    Kanata, Naoki
    Murakami, Tohru
    Kawamitsu, Hideaki
    Sugimura, Kazuro
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3048 - 3054
  • [46] Does Perfusion Computed Tomography Facilitate Clinical Decision Making for Thrombolysis in Unselected Acute Patients with Suspected Ischaemic Stroke?
    Agarwal, S.
    Jones, P. S.
    Alawneh, J. A.
    Antoun, N. M.
    Barry, P. J.
    Carrera, E.
    Cotter, P. E.
    O'Brien, E. W.
    Salih, I.
    Scoffings, D. J.
    Baron, J. -C.
    Warburton, E. A.
    [J]. CEREBROVASCULAR DISEASES, 2011, 32 (03) : 227 - 233
  • [47] Whole-Organ CT Perfusion of the Pancreas: Impact of Iterative Reconstruction on Image Quality, Perfusion Parameters and Radiation Dose in 256-Slice CT-Preliminary Findings
    Xie, Qian
    Wu, Juan
    Tang, Ying
    Dou, Yafang
    Hao, Sijie
    Xu, Feijia
    Feng, Xiaoyuan
    Liang, Zonghui
    [J]. PLOS ONE, 2013, 8 (11):
  • [48] In patients with suspected acute stroke, CT perfusion-based cerebral blood flow maps cannot substitute for DWI in measuring the ischemic core
    Copen, William A.
    Yoo, Albert J.
    Rost, Natalia S.
    Morais, Livia T.
    Schaefer, Pamela W.
    Gonzalez, R. Gilberto
    Wu, Ona
    [J]. PLOS ONE, 2017, 12 (11):
  • [49] Efficacy of Peripheral Interventional Radiologists Performing Endovascular Stroke Therapy Guided by CT Perfusion Triage of Patients
    Burkart, David J.
    Day, Jason S.
    Henderson, Kathleen
    Borsa, John J.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (09) : 1267 - 1272
  • [50] Noise Reduction and Image Quality Improvement of Low Dose and Ultra Low Dose Brain Perfusion CT by HYPR-LR Processing
    Krissak, Radko
    Mistretta, Charles A.
    Henzler, Thomas
    Chatzikonstantinou, Anastasios
    Scharf, Johann
    Schoenberg, Stefan O.
    Fink, Christian
    [J]. PLOS ONE, 2011, 6 (02):