Impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion in patients with suspected stroke

被引:0
作者
Rau, Alexander [1 ,2 ]
Reisert, Marco [3 ,4 ]
Stein, Thomas [2 ]
Mueller-Peltzer, Katharina [2 ]
Rau, Stephan [2 ]
Bamberg, Fabian [2 ]
Taschner, Christian A. [1 ]
Urbach, Horst [1 ]
Kellner, Elias [3 ]
机构
[1] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Neurol & Clin Neurosci, Freiburg, Germany
[2] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Freiburg, Germany
[3] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Med Phys, Freiburg, Germany
[4] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Stereotact & Funct Neurosurg, Freiburg, Germany
关键词
Perfusion; Stroke; Radiation dosage; Computed tomography; ACUTE ISCHEMIC-STROKE; VOLUME; PARAMETERS; SOFTWARE; EXPOSURE;
D O I
10.1007/s00234-024-03335-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeCT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke.MethodsWe retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared.ResultsThe agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4.ConclusionReducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.
引用
收藏
页码:749 / 759
页数:11
相关论文
共 50 条
  • [21] CT perfusion with increased temporal sampling interval to predict target mismatch status in patients with acute ischemic stroke
    Gao Ma
    Yue-Zhou Cao
    Guang-Chen Shen
    Shan-Shan Lu
    Ya-Xi Zhang
    Yu Zhang
    Hai-Bin Shi
    Xiao-Quan Xu
    Fei-Yun Wu
    Neuroradiology, 2023, 65 : 105 - 111
  • [22] Optimal Brain Perfusion CT Coverage in Patients with Acute Middle Cerebral Artery Stroke
    Furtado, A. D.
    Lau, B. C.
    Vittinghoff, E.
    Dillon, W. P.
    Smith, W. S.
    Rigby, T.
    Boussel, L.
    Wintermark, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (04) : 691 - 695
  • [23] Impact of dose reduction and iterative model reconstruction on multi-detector CT imaging of the brain in patients with suspected ischemic stroke
    Paprottka, Karolin J.
    Kupfer, Karina
    Riederer, Isabelle
    Zimmer, Claus
    Beer, Meinrad
    Noel, Peter B.
    Baum, Thomas
    Kirschke, Jan S.
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV)
    Li, Zhen-lin
    Li, Hang
    Zhang, Kai
    Li, Wang-jiang
    Chen, Xian
    Wu, Bin
    Song, Bin
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1906 - 1913
  • [25] Feasibility of radiation dose reduction using AIDR-3D in dynamic pulmonary CT perfusion
    Mirsadraee, S.
    Weir, N. W.
    Connolly, S.
    Murchison, J. T.
    Reid, J. H.
    Hirani, N.
    Connell, M.
    van Beek, E. J.
    CLINICAL RADIOLOGY, 2015, 70 (08) : 844 - 851
  • [26] Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network
    Moghari, Mahdieh Dashtbani
    Sanaat, Amirhossein
    Young, Noel
    Moore, Krystal
    Zaidi, Habib
    Evans, Andrew
    Fulton, Roger R.
    Kyme, Andre Z.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (16)
  • [27] Prediction of outcome in patients with suspected acute ischaemic stroke with CT perfusion and CT angiography: the Dutch acute stroke trial (DUST) study protocol
    van Seeters, Tom
    Biessels, Geert Jan
    van der Schaaf, Irene C.
    Dankbaar, Jan Willem
    Horsch, Alexander D.
    Luitse, Merel J. A.
    Niesten, Joris M.
    Mali, Willem P. T. M.
    Kappelle, L. Jaap
    van der Graaf, Yolanda
    Velthuis, Birgitta K.
    BMC NEUROLOGY, 2014, 14
  • [28] 3D movement correction of CT brain perfusion image data of patients with acute ischemic stroke
    Fahmi, Fahmi
    Marquering, Henk A.
    Borst, Jordi
    Streekstra, Geert J.
    Beenen, Ludo F. M.
    Niesten, Joris M.
    Velthuis, Birgitta K.
    Majoie, Charles B. L.
    vanBavel, Ed
    NEURORADIOLOGY, 2014, 56 (06) : 445 - 452
  • [29] Radiation Dose Reduction in CT Myocardial Perfusion Imaging Using SMART-RECON
    Li, Yinsheng
    Speidel, Michael A.
    Francois, Christopher J.
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (12) : 2557 - 2568
  • [30] Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study
    Fang, Xiao Kun
    Ni, Qian Qian
    Schoepf, U. Joseph
    Zhou, Chang Sheng
    Chen, Guo Zhong
    Luo, Song
    Fuller, Stephen R.
    De Cecco, Carlo N.
    Zhang, Long Jiang
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 4184 - 4193