Impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion in patients with suspected stroke

被引:0
|
作者
Rau, Alexander [1 ,2 ]
Reisert, Marco [3 ,4 ]
Stein, Thomas [2 ]
Mueller-Peltzer, Katharina [2 ]
Rau, Stephan [2 ]
Bamberg, Fabian [2 ]
Taschner, Christian A. [1 ]
Urbach, Horst [1 ]
Kellner, Elias [3 ]
机构
[1] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Neurol & Clin Neurosci, Freiburg, Germany
[2] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Freiburg, Germany
[3] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Med Phys, Freiburg, Germany
[4] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Stereotact & Funct Neurosurg, Freiburg, Germany
关键词
Perfusion; Stroke; Radiation dosage; Computed tomography; ACUTE ISCHEMIC-STROKE; VOLUME; PARAMETERS; SOFTWARE; EXPOSURE;
D O I
10.1007/s00234-024-03335-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeCT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke.MethodsWe retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared.ResultsThe agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4.ConclusionReducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.
引用
收藏
页码:749 / 759
页数:11
相关论文
共 50 条
  • [11] CT perfusion with increased temporal sampling interval to predict target mismatch status in patients with acute ischemic stroke
    Ma, Gao
    Cao, Yue-Zhou
    Shen, Guang-Chen
    Lu, Shan-Shan
    Zhang, Ya-Xi
    Zhang, Yu
    Shi, Hai-Bin
    Xu, Xiao-Quan
    Wu, Fei-Yun
    NEURORADIOLOGY, 2023, 65 (01) : 105 - 111
  • [12] Dose reduction in perfusion CT in stroke patients by lowering scan frequency does not affect automatically calculated infarct core volumes
    Karwacki, Grzegorz Marek
    Vogele, Stephan
    Blackham, Kristine Ann
    JOURNAL OF NEURORADIOLOGY, 2019, 46 (06) : 351 - 358
  • [13] Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke
    Othman, Ahmed E.
    Brockmann, Carolin
    Yang, Zepa
    Kim, Changwon
    Afat, Saif
    Pjontek, Rastislav
    Nikobashman, Omid
    Brockmann, Marc A.
    Kim, Jong Hyo
    Wiesmann, Martin
    EUROPEAN RADIOLOGY, 2015, 25 (12) : 3415 - 3422
  • [14] Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke
    Ahmed E. Othman
    Carolin Brockmann
    Zepa Yang
    Changwon Kim
    Saif Afat
    Rastislav Pjontek
    Omid Nikobashman
    Marc A. Brockmann
    Jong Hyo Kim
    Martin Wiesmann
    European Radiology, 2015, 25 : 3415 - 3422
  • [15] CT Perfusion in Acute Ischemic Stroke: A Comparison of 2-Second and 1-Second Temporal Resolution
    Abels, B.
    Klotz, E.
    Tomandl, B. F.
    Villablanca, J. P.
    Kloska, S. P.
    Lell, M. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) : 1632 - 1639
  • [16] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [17] CT brain perfusion: A static phantom study of contrast-to-noise ratio and radiation dose
    Midgley, Stewart M.
    Stella, Damien L.
    Campbell, Bruce C. V.
    Langenberg, Francesca
    Einsiedel, Paul F.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (03) : 361 - 366
  • [18] QUANTITATIVE DYNAMIC PERFUSION CT BRAIN IN PATIENTS WITH STROKE
    Chidambaram, Prem Kumar
    Kumar, Ram S.
    Vadanika, V.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (87): : 15147 - 15152
  • [19] Radiation dose reduction in computed tomography perfusion using spatial-temporal Bayesian methods
    Fang, Ruogu
    Raj, Ashish
    Chen, Tsuhan
    Sanelli, Pina C.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [20] Robust cranial cavity segmentation in CT and CT perfusion images of trauma and suspected stroke patients
    Patel, Ajay
    van Ginneken, Bram
    Meijer, Frederick J. A.
    van Dijk, Ewoud J.
    Prokop, Mathias
    Manniesing, Rashindra
    MEDICAL IMAGE ANALYSIS, 2017, 36 : 216 - 228