Accura balloon dilatation catheter for percutaneous balloon pulmonary valvuloplasty among adult patients-its protean use

被引:0
作者
Sofi, Najeeb Ullah [1 ]
Sachan, Mohit [1 ]
Sinha, Santosh K. [1 ]
Jha, Mukesh J. [1 ]
Pandey, Umeshwar [1 ]
Razi, Mahmodullah [1 ]
Sharma, Awadhesh K. [1 ]
Shukla, Praveen [1 ]
Aggarwal, Puneet [2 ]
Himanshu, Kumar [1 ]
Sharma, Prachi [1 ]
Thakur, Ramesh [1 ]
机构
[1] GSVM Med Coll, LPS Inst Cardiol, Dept Cardiol, Kanpur, Uttar Pradesh, India
[2] ABVIMS & Dr RML Hosp, Dept Cardiol, New Delhi, India
来源
AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE | 2023年 / 13卷 / 03期
关键词
Pulmonary stenosis; Accura balloon; tyshak balloon; percutaneous balloon pulmonary valvuloplasty; cardiac perforation; tamponade; STENOSIS; TERM; ADOLESCENTS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Percutaneous balloon pulmonary valvuloplasty (PBPV) is the treatment of choice for hemody-namically significant pulmonary stenosis (PS). Currently, the Tyshak balloon is preferred but requires multiple dilata-tions because of its instability across the valve leading to a watermelon seeding effect. Accura balloon (Vascular Concept, UK) offers an advantage in its self-positioning configuration, variable diameter, and rapid inflation-deflation sequence which shortens the procedural time and valve injury. Method: 43 patients with severe pulmonary valve stenosis underwent PBPV using an Accura balloon at LPS Institute of Cardiology, GSVM Medical College, Kanpur, UP, India from March 2018 to February 2022. The procedure was carried out using the standard technique but the metallic straightener was removed when the catheter reached the right atrium to facilitate its delivery across the pulmonary valve. Patients were followed up by 2D echo at 24 hours and 6 months. Result: Successful BPV was done in all 43 patients [with mean age 21.9 (range 18-41); 31 males and 12 females] among which 5 patients had dysplastic valves. The mean diameter of the annulus was 18.5 (range 15-21) mm. Immediate hemodynamic improvement was observed in 38 patients (88%) as peak systolic gradient reduced from 84 & PLUSMN;13 to 22 & PLUSMN;12 mmHg (P<0.005) while 5 patients (12%) had <50% reduction of resting gradient, though it came down significantly at 6 months. Fluoroscopy and procedural time were 5.2 & PLUSMN;1.9 min and 22.6 & PLUSMN;3.4 min respectively. Major complications (death, cardiac perforation, tamponade, tricuspid regurgitation, requirement of blood transfusion) were none. Minor complications (transient hypotension, ventricular premature contraction, transient bradycardia) were reported in all patients. Accura balloon being bulky were delivered over left atrial and super stiff Amplatz wire in 36 and 7 patients respectively. Conclusion: PBPV using Accura balloon is safe and effective for both stenosed and dysplastic valves. In a few patients, maximal effect will be observed over a period of 6 months.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 16 条
  • [1] PERCUTANEOUS DOUBLE BALLOON PULMONARY VALVOTOMY IN ADULTS - ONE-YEAR TO 2-YEAR FOLLOW-UP
    ALKASAB, S
    RIBEIRO, PA
    ALZAIBAG, M
    HALIM, M
    HABBAB, MA
    SHAHID, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (10) : 822 - 824
  • [2] Versatility of Inoue balloon catheter
    Bahl, VK
    Chandra, S
    Goel, A
    Goswami, KC
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1997, 59 (01) : 75 - 83
  • [3] Percutaneous balloon valvuloplasty for pulmonic stenosis in adolescents and adults
    Chen, CR
    Cheng, TO
    Huang, T
    Zhou, UL
    Chen, JY
    Huang, YG
    Li, HJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (01) : 21 - 25
  • [4] Cooper J W, 1989, J Am Soc Echocardiogr, V2, P56
  • [5] Deora Surender, 2014, Indian Heart J, V66, P211, DOI 10.1016/j.ihj.2013.12.010
  • [6] Long-term results (up to 17 years) of pulmonary balloon valvuloplasty in adults and its effects on concomitant severe infundibular stenosis and tricuspid regurgitation
    Fawzy, Mohamed Eid
    Hassan, Walid
    Fadel, Bahaa M.
    Sergani, Hani
    El Shaer, Fayez
    El Widaa, Hassan
    Al Sanei, Aly
    [J]. AMERICAN HEART JOURNAL, 2007, 153 (03) : 433 - 438
  • [7] ANATOMIC FEATURES OF CONGENITAL PULMONARY VALVAR STENOSIS
    GIKONYO, BM
    LUCAS, RV
    EDWARDS, JE
    [J]. PEDIATRIC CARDIOLOGY, 1987, 8 (02) : 109 - 116
  • [8] Lanjewar C, 2017, INDIAN HEART J, V69, P176, DOI 10.1016/j.ihj.2016.11.316
  • [9] Comparison of Immediate and Long-term Results between the Single Balloon and Inoue Balloon Techniques for Percutaneous Pulmonary Valvuloplasty
    Liu, Suxuan
    Xu, Xudong
    Liu, Guanzhong
    Ding, Xueyan
    Zhao, Xianxian
    Qin, Yongwen
    [J]. HEART LUNG AND CIRCULATION, 2015, 24 (01) : 40 - 45
  • [10] Patel TM, 1996, J INVASIVE CARDIOL, V8, P374