Simple high-performance liquid chromatography-ultraviolet method for simultaneous separation and detection of 14 bisphenol pollutants in building materials

被引:4
|
作者
Han, Xiaoxuan [1 ]
Zhao, Ruijie [1 ]
Tian, Yong [2 ,5 ]
Li, Yutong [1 ]
Chen, Xu-Wei [1 ]
Ma, Jiping [2 ]
Wang, Weiliang [2 ]
Zhang, Yanfeng [3 ,6 ]
Geng, Song [3 ]
Liu, Menglin [4 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Dept Chem, Shenyang, Peoples R China
[2] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[3] Intelligent Policing Key Lab Sichuan Prov, Luzhou, Peoples R China
[4] Rizhao Custom, Rizhao, Peoples R China
[5] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[6] Intelligent Policing Key Lab Sichuan Prov, Luzhou 646000, Peoples R China
基金
中国国家自然科学基金;
关键词
bisphenols; building material; high performance-liquid chromatography; separation; ultraviolet detector; SOLID-PHASE EXTRACTION; UNITED-STATES; WATER SAMPLES; INDOOR DUST; ANALOGS; EXPOSURE; JAPAN; KOREA;
D O I
10.1002/jssc.202300006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatography-ultraviolet method was developed for rapidly and simultaneously analyzing novel and typical bisphenols in building materials, including bisphenol S, diphenolic acid, bisphenol F, bisphenol E, bisphenol A, bisphenol B, bisphenol AF, bisphenol AP, bisphenol C, bisphenol FL, bisphenol Z, bisphenol BP, bisphenol M, and bisphenol P. By using a Kromasil 100-5 C18 column, these bisphenols were completely separated in 40 min via gradually increasing the concentration of methanol in the mobile phase from 45 to 80% during the elution process. In particular, this method achieved the synchronous analysis of bisphenol S, diphenolic acid, bisphenol FL, bisphenol BP, and bisphenol M through HPLC, which were difficult to separate and had to be identified and detected through mass spectrometry. The limits of detection of the method ranged from 0.002 to 0.040 mg/L for these 14 bisphenols, with a precision of less than 4.9% (n = 7, c = 0.05 mg/L). The analytical results for five types of building materials (phenolic, epoxy, polycarbonate, polyester, and polysulfone resins) indicated that the proposed method is appropriated for the rapid measurement of bisphenols in real samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A practical guide to the analysis of sirolimus using high-performance liquid chromatography with ultraviolet detection
    Napoli, KL
    CLINICAL THERAPEUTICS, 2000, 22 : B14 - B24
  • [42] Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method
    Klapkova, Eva
    Fortova, Magdalena
    Prusa, Richard
    Moravcova, Libuse
    Kotaska, Karel
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (06) : 1226 - 1231
  • [43] Determination of sirolimus in blood by high-performance liquid chromatography with ultraviolet detection - Experience and review
    Wu, FLL
    Chen, RRL
    Lee, SS
    Sun, SW
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2005, 13 (01) : 1 - 11
  • [44] A high-performance liquid chromatography method for the detection of diaminopimelic acid in urine
    Borruat, G
    Roten, CAH
    Fay, LB
    Karamata, D
    ANALYTICAL BIOCHEMISTRY, 2001, 291 (01) : 11 - 16
  • [45] A SIMPLE, RAPID METHOD FOR THE SIMULTANEOUS DETERMINATION OF MORPHINE AND ITS PRINCIPAL METABOLITES IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUOROMETRIC DETECTION
    GLARE, PA
    WALSH, TD
    PIPPENGER, CE
    THERAPEUTIC DRUG MONITORING, 1991, 13 (03) : 226 - 232
  • [46] Determination of meropenem levels in human serum by high-performance liquid chromatography with ultraviolet detection
    Roth, Thomas
    Fiedler, Stella
    Mihai, Sidonia
    Parsch, Hans
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (05)
  • [47] Far-ultraviolet absorbance detection of sugars and peptides by high-performance liquid chromatography
    Uchiho, Yuichi
    Goto, Yusuke
    Kamahori, Masao
    Aota, Toshimichi
    Morisaki, Atsuki
    Hosen, Yusuke
    Koda, Kimiyoshi
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1424 : 86 - 91
  • [48] Determination of lipoic acid in human plasma by high-performance liquid chromatography with ultraviolet detection
    Chwatko, Grazyna
    Krawczyk, Marta
    Iciek, Malgorzata
    Kaminska, Adrianna
    Bilska-Wilkosz, Anna
    Marcykiewicz, Bernadeta
    Glowacki, Rafal
    ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (08) : 4878 - 4886
  • [49] The Investigation of Bisphenol a Presence in Canned Tuna Fish using High-Performance Liquid Chromatography Method
    Er, Buket
    Sarimehmetoglu, Belgin
    JOURNAL OF ANIMAL AND VETERINARY ADVANCES, 2011, 10 (21): : 2859 - 2862
  • [50] Sugaring-Out Assisted Liquid-Liquid Extraction Combined with High-Performance Liquid Chromatography-Fluorescence Detection for the Determination of Bisphenol A and Bisphenol B in Royal Jelly
    Tu, Xijuan
    Wu, Siyuan
    Liu, Weiyi
    Gao, Zhaosheng
    Huang, Shaokang
    Chen, Wenbin
    FOOD ANALYTICAL METHODS, 2019, 12 (03) : 705 - 711