Simple high-performance liquid chromatography-ultraviolet method for simultaneous separation and detection of 14 bisphenol pollutants in building materials

被引:4
|
作者
Han, Xiaoxuan [1 ]
Zhao, Ruijie [1 ]
Tian, Yong [2 ,5 ]
Li, Yutong [1 ]
Chen, Xu-Wei [1 ]
Ma, Jiping [2 ]
Wang, Weiliang [2 ]
Zhang, Yanfeng [3 ,6 ]
Geng, Song [3 ]
Liu, Menglin [4 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Dept Chem, Shenyang, Peoples R China
[2] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[3] Intelligent Policing Key Lab Sichuan Prov, Luzhou, Peoples R China
[4] Rizhao Custom, Rizhao, Peoples R China
[5] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[6] Intelligent Policing Key Lab Sichuan Prov, Luzhou 646000, Peoples R China
基金
中国国家自然科学基金;
关键词
bisphenols; building material; high performance-liquid chromatography; separation; ultraviolet detector; SOLID-PHASE EXTRACTION; UNITED-STATES; WATER SAMPLES; INDOOR DUST; ANALOGS; EXPOSURE; JAPAN; KOREA;
D O I
10.1002/jssc.202300006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatography-ultraviolet method was developed for rapidly and simultaneously analyzing novel and typical bisphenols in building materials, including bisphenol S, diphenolic acid, bisphenol F, bisphenol E, bisphenol A, bisphenol B, bisphenol AF, bisphenol AP, bisphenol C, bisphenol FL, bisphenol Z, bisphenol BP, bisphenol M, and bisphenol P. By using a Kromasil 100-5 C18 column, these bisphenols were completely separated in 40 min via gradually increasing the concentration of methanol in the mobile phase from 45 to 80% during the elution process. In particular, this method achieved the synchronous analysis of bisphenol S, diphenolic acid, bisphenol FL, bisphenol BP, and bisphenol M through HPLC, which were difficult to separate and had to be identified and detected through mass spectrometry. The limits of detection of the method ranged from 0.002 to 0.040 mg/L for these 14 bisphenols, with a precision of less than 4.9% (n = 7, c = 0.05 mg/L). The analytical results for five types of building materials (phenolic, epoxy, polycarbonate, polyester, and polysulfone resins) indicated that the proposed method is appropriated for the rapid measurement of bisphenols in real samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A simple and economic method for simultaneous determination of 11 antibiotics in manure by solid-phase extraction and high-performance liquid chromatography
    Feng, Yao
    Wei, Chaojun
    Zhang, Wenjuan
    Liu, Yuanwang
    Li, Zhaojun
    Hu, Haiyan
    Xue, Jianming
    Davis, Murray
    JOURNAL OF SOILS AND SEDIMENTS, 2016, 16 (09) : 2242 - 2251
  • [32] Magnetic nanofluid based on green deep eutectic solvent for enrichment and determination of chloramphenicol in milk and chicken samples by high-performance liquid chromatography-ultraviolet: Optimization of microextraction
    Mehrabi, Fatemeh
    Ghaedi, Mehrorang
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1689
  • [33] Determination of macelignan in rat plasma by high-performance liquid chromatography with ultraviolet detection
    Ming Ji Jin
    Kisoo Seo
    Ilho Ha
    Hyo-Kyung Han
    Archives of Pharmacal Research, 2008, 31 : 945 - 949
  • [34] Development and evaluation of a simple and easy high-performance liquid chromatography-ultraviolet system simultaneously suitable for determination of 24 anti-epileptic drugs in plasma
    Zhao, Yan-lin
    Zhao, Lin-lin
    You, Yu-xin
    Zheng, Xiao-xiao
    Du, Yan
    Tang, Dao-quan
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (13) : 2161 - 2176
  • [35] A simple and economic method for simultaneous determination of 11 antibiotics in manure by solid-phase extraction and high-performance liquid chromatography
    Yao Feng
    Chaojun Wei
    Wenjuan Zhang
    Yuanwang Liu
    Zhaojun Li
    Haiyan Hu
    Jianming Xue
    Murray Davis
    Journal of Soils and Sediments, 2016, 16 : 2242 - 2251
  • [36] AN IMPROVED METHOD FOR THE DETERMINATION OF URINARY 1-HYDROXYPYRENE BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    Lu, Shaoyou
    Fan, Ruifang
    Yu, Zhiqiang
    Sheng, Guoying
    Fu, Jiamo
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (11) : 1528 - 1537
  • [37] Electromembrane extraction-high-performance liquid chromatography-ultraviolet detection of phenobarbital and phenytoin in human plasma, saliva, and urine
    Dolatabadi, Roshanak
    Mohammadi, Ali
    Nojavan, Saeed
    Yaripour, Saeid
    Tafakhori, Abbas
    Shirangi, Mehrnoosh
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (08) : 1522 - 1530
  • [38] Simultaneous determination of some ultraviolet-absorbing chemicals in sunscreen cosmetics using a high-performance liquid chromatography method
    Liu, T.
    Wu, D.
    INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 2011, 33 (05) : 408 - 415
  • [39] Screening, recognition and quantitation of salbutamol residues in ham sausages by molecularly imprinted solid phase extraction coupled with high-performance liquid chromatography-ultraviolet detection
    Yan, Hongyuan
    Wang, Ruiling
    Han, Yehong
    Liu, Suting
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 900 : 18 - 23
  • [40] Determination of 5-methyl-2′-deoxycytidine in genomic DNA using high performance liquid chromatography-ultraviolet detection
    Sandhu, Jatinderpal
    Kaur, Balvinder
    Armstrong, Christine
    Talbot, Christopher J.
    Steward, William P.
    Farmer, Peter B.
    Singh, Rajinder
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (20-21): : 1957 - 1961