Simple high-performance liquid chromatography-ultraviolet method for simultaneous separation and detection of 14 bisphenol pollutants in building materials

被引:4
|
作者
Han, Xiaoxuan [1 ]
Zhao, Ruijie [1 ]
Tian, Yong [2 ,5 ]
Li, Yutong [1 ]
Chen, Xu-Wei [1 ]
Ma, Jiping [2 ]
Wang, Weiliang [2 ]
Zhang, Yanfeng [3 ,6 ]
Geng, Song [3 ]
Liu, Menglin [4 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Dept Chem, Shenyang, Peoples R China
[2] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[3] Intelligent Policing Key Lab Sichuan Prov, Luzhou, Peoples R China
[4] Rizhao Custom, Rizhao, Peoples R China
[5] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[6] Intelligent Policing Key Lab Sichuan Prov, Luzhou 646000, Peoples R China
基金
中国国家自然科学基金;
关键词
bisphenols; building material; high performance-liquid chromatography; separation; ultraviolet detector; SOLID-PHASE EXTRACTION; UNITED-STATES; WATER SAMPLES; INDOOR DUST; ANALOGS; EXPOSURE; JAPAN; KOREA;
D O I
10.1002/jssc.202300006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatography-ultraviolet method was developed for rapidly and simultaneously analyzing novel and typical bisphenols in building materials, including bisphenol S, diphenolic acid, bisphenol F, bisphenol E, bisphenol A, bisphenol B, bisphenol AF, bisphenol AP, bisphenol C, bisphenol FL, bisphenol Z, bisphenol BP, bisphenol M, and bisphenol P. By using a Kromasil 100-5 C18 column, these bisphenols were completely separated in 40 min via gradually increasing the concentration of methanol in the mobile phase from 45 to 80% during the elution process. In particular, this method achieved the synchronous analysis of bisphenol S, diphenolic acid, bisphenol FL, bisphenol BP, and bisphenol M through HPLC, which were difficult to separate and had to be identified and detected through mass spectrometry. The limits of detection of the method ranged from 0.002 to 0.040 mg/L for these 14 bisphenols, with a precision of less than 4.9% (n = 7, c = 0.05 mg/L). The analytical results for five types of building materials (phenolic, epoxy, polycarbonate, polyester, and polysulfone resins) indicated that the proposed method is appropriated for the rapid measurement of bisphenols in real samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Polyaniline-co-polyindole functionalized magnetic porous carbon derived from MIL-53(Fe) for separation/enrichment of nitrophenols pollutants before determination with high-performance liquid chromatography-ultraviolet detection
    Barzin, Mahnaz
    Pooladi, Mohsen
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (16)
  • [22] Application of covalent organic framework as the adsorbent for solid-phase extraction of trace levels of pesticide residues prior to high-performance liquid chromatography-ultraviolet detection
    Song, Yuhong
    Ma, Ruiyang
    Hao, Lin
    Yang, Xiumin
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1572 : 20 - 26
  • [23] Determination of macelignan in rat plasma by high-performance liquid chromatography with ultraviolet detection
    Jin, Ming Ji
    Seo, Kisoo
    Ha, Ilho
    Han, Hyo-Kyung
    ARCHIVES OF PHARMACAL RESEARCH, 2008, 31 (07) : 945 - 949
  • [24] Measurement of plasma busulfan concentration by high-performance liquid chromatography with ultraviolet detection
    Rifai, N
    Sakamoto, M
    Lafi, M
    Guinan, E
    THERAPEUTIC DRUG MONITORING, 1997, 19 (02) : 169 - 174
  • [25] A quantitative method for the determination of bosutinib in human plasma using high-performance liquid chromatography and ultraviolet detection
    Sumimoto, Takahiro
    Nakahara, Ryosuke
    Sato, Yuhki
    Itoh, Hiroki
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)
  • [26] Determination of several estrogens in serum by high-performance liquid chromatography with ultraviolet detection
    Cai, YQ
    Wang, L
    Liang, LN
    Liu, JS
    Shi, YL
    Mou, SF
    Jiang, GB
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (07) : 913 - 916
  • [27] High-performance liquid chromatography with ultraviolet detection for therapeutic drug monitoring of everolimus
    Baldelli, S
    Murgia, S
    Merlini, S
    Zenoni, S
    Perico, N
    Remuzzi, G
    Cattaneo, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 99 - 105
  • [28] Determination of Bisphenol A and Alkylphenols in Soft Drinks by High-Performance Liquid Chromatography with Fluorescence Detection
    Li, Yanxin
    Zhang, Shijuan
    Song, Cuihua
    You, Jinmao
    FOOD ANALYTICAL METHODS, 2013, 6 (05) : 1284 - 1290
  • [29] Simultaneous determination of opioid drugs in urine with high-performance liquid chromatography-ultraviolet after supramolecular based magnetic NP solid-phase extraction
    Zabardasti, Abedien
    Afrouzi, Hossein
    Kakanejadifard, Ali
    Amoli-Diva, Mitra
    MICRO & NANO LETTERS, 2017, 12 (03): : 182 - 186
  • [30] A reliable high-performance liquid chromatography with ultraviolet detection for the determination of sulfonamides in honey
    Granja, Rodrigo H. M. M.
    Montes Nino, Alfredo M.
    Rabone, Fernanda
    Salerno, Alessandro Gonzalez
    ANALYTICA CHIMICA ACTA, 2008, 613 (01) : 116 - 119